• Title/Summary/Keyword: Energy losses

Search Result 707, Processing Time 0.026 seconds

Losses in Power Distribution Transformers

  • Ketkaew, Chaliew;Philphud, Mana;Sungthong, Tossapol;Rachawong, Wiriya;Kalong, Putchong;Noohawm, Onurai;Rerkpreedapong, Dulpichet
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.144-148
    • /
    • 2015
  • The paper presents the estimation of power losses in distribution transformer of Provincial Electricity Authority (PEA) distribution system at Muang district of Suphanburi province in Thailand. Data of 416 power distribution transformers composed of transformer (kVA), load current, no load loss and full load loss which were used for calculating energy losses. It was found that the total energy loss of all transformers is approximately 1,756,380 kWh/year.

Harmonic Distortion Contribution for the Transmission Loss Allocation in Deregulated Energy Market: A New Scheme for Industry Consumer

  • Nojeng, Syarifuddin;Hassan, Mohammad Yusri;Said, Dalila Mat;Abdullah, Md.Pauzi;Hussin, Faridah
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • The industry has rapidly growth and energy supply technology advanced are become main factor which to contribute of the harmonic losses. This problem is one aspect that may affect the capability of the transmission line and also to the efficiency of electricity. This paper proposes a new scheme to allocate the cost pertaining to transmission loss due to harmonics. The proposed method, called as Generalized Harmonic Distribution Factor, uses the principle of proportional sharing method to allocate the losses among the transmission users especially for industry consumers. The IEEE 14- and 30 bus test system is used to compare the proposed method with existing method. The results showed that the proposed method provided a scheme better in allocating the cost of transmission loss, which could encourage the users to minimize the losses.

Determination of the Optimal PTC Receiver Diameter Considering Heat Losses (열손실을 고려한 PTC(Parabolic Trough Concentrator) 흡수기 최적 직경 결정에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Yoon, H.K.;Yoo, C.K.;Lee, D.G.;Seo, T.B.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2000
  • Considering the optical performance of the reflector and analyzing heat losses from the receiver, the optimal diameter of the absorber for a PTC(Parabolic Trough Concentrator) system was numerically determined. The results of this study were compared with the results of the IST (Industrial Solar Technology)-PTC test to verify the validity of the model. Good agreement was obtained with the deviation range from 0.4 to 7.7%. Generally, the net energy gained by the receiver shows the maximum at the particular absorber diameter and the specific gap size between the absorber and the glass envelop because the heat losses from the receiver becomes the minimum. The results showed that the conductive and convective heat losses became the minimum when the gap size was 7 to 10mm. Finally, it was known that the optimal absorber diameter was 62mm at $100^{\circ}C$, 57mm at $150^{\circ}C$, and 53mm at $200^{\circ}C$ of the absorber surface temperature, respectively.

  • PDF

Estimation of Heat Losses From the Receivers for Solar Energy Collecting System of Korea Institute of Energy Research

  • Ryu, Siyoul;Seo, Taebeom
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.12
    • /
    • pp.1403-1411
    • /
    • 2000
  • Heat losses from the receivers for a dish-type solar energy collecting system constructed at Korea Institute of Energy Research are analyzed. The Stine and McDonald's model is used to estimate the convection loss. The Net Radiation method and the Monte-Carlo method are used to calculate the radiation heat transfer rate from the inside surface of the receiver to the surroundings. Two different receivers are suggested here and the performances of the receivers are estimated and compared with each other based on the prediction of the amount of heat losses from the receivers. The effects of the receiver shape and the radiation properties of the surface on the thermal performance are investigated. The performance of Receiver I is better than that of Receiver II, and the amount of solar irradiation that is not captured by the captured by the receiver after being reflected by the concentrator becomes significant if the temperature of the working fluid is low.

  • PDF

Analysis of Energy Losses in a Natural Gas Spark Ignition Engine for Power Generation (천연가스 스파크점화 엔진 발전기에서의 에너지 손실 분석)

  • Park, Hyunwook;Lee, Junsun;Oh, Seungmook;Kim, Changup;Lee, Yongkyu;Kang, Kernyong
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.170-177
    • /
    • 2020
  • Stoichiometric combustion in spark ignition (SI) engines has an advantage of meeting future stringent emission regulations. However, the drawback of the combustion is a lower thermal efficiency than that of lean burn. In this study, energy losses in a natural gas stoichiometric SI engine generator were analyzed to establish a strategy for improving the generating efficiency (GE). The energy losses were investigated based on dynamometer and load bank experiments. As the intake manifold pressure increased in the dynamometer experiment, the brake thermal efficiency (BTE) increased mainly due to the reduction in the pumping and mechanical losses. In the load bank experiment, the generating power and GE increased with the increased intake manifold pressure. The generating power and GE were lower than the brake power and BTE due to the cooling fan power and the losses in the generator.

Analysis of losses within SMES system for compensating output fluctuation of wind power farm

  • Park, S.I.;Kim, J.H.;Le, T.D.;Lee, D.H.;Kim, D.J.;Yoon, Y.S.;Yoon, K.Y.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.57-61
    • /
    • 2014
  • Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

Losses Comparison and Analysis for Fault Modes of Grid-connected Photovoltaic System (계통연계형 태양광발전 시스템의 고장유형별 손실 비교분석)

  • So, Jung-Hun;Ko, Suk-Whan;Ju, Young-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.23-32
    • /
    • 2017
  • This paper presents losses comparison and analysis results for different types of fault modes of grid-connected photovoltaic system generated for long-term operation. The approach of losses comparison and analysis by faults is to identify relationship between measured and estimated values of five loss factors which are quantified from irradiance to system output power. This paper presents the symptom results for faults such as snow, shading, sensor defect, blackout, soiling and so on from three years or more monitored data. These results will indicate that it is useful to develop fault detection and diagnosis tool to enhance capacity factor and save operation and maintenance cost of grid-connected photovoltaic system in the field.

Effect of Bundle Junction Face and Misalignment on the Pressure Drops Across a Randomly Loaded and Aligned 12 Bundles in Candu Fuel Channel

  • H. C. Suk;K. S. Sim;C. H. Chung;Lee, Y. O.
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.280-289
    • /
    • 1996
  • The pressure drop of twelve fuel bundle string in the CANDU-6 fuel channel is equal to the sum of the eleven junction pressure losses, the bundle string entrance and exit pressure losses, the skin friction pressure loss, and other appendage pressure losses, where the junction loss is dependent on the bundle end faces and angular alignments of the junctions. The results of the single junction pressure drop tests in a short rig show that the most probable pressure drop of the eleven junctions was analytically equal to the eleven times of average pressure drop of all the possible single junction pressure drops, and also that the largest and smallest junction pressure drops across the eleven junctions probably occurred only with BA and BB type junctions, respectively, where A and B denote the bundle end sides with an end-plates on which a company monogram is stamped and unstamped, respectively.

  • PDF

Factors Affecting True Metabolizable Energy Determination of Poultry Feedingstuffs Effect of level of feed input and diet types on apparent and true metabolizable energy of corn and soybean meal. (양계사료의 TME측정에 영향하는 요인에 관한 시험 II. 사료투입량 및 사료급여형태가 옥수수와 대두박의 대사 에너지가에 미치는 영향)

  • 이영철;강도환
    • Korean Journal of Poultry Science
    • /
    • v.10 no.1
    • /
    • pp.46-52
    • /
    • 1983
  • The study was carried out to examine factors affecting metabolic plus endogenous one.9y (FEm+UEe) losses by adult roosters. Experiment one was performed to examine the effect of excreta collecting period and Experiment two, of feeding soluble carbohydrates (corn starch and glucose) to birds on FEm+UEe losses. The results obtained were as follows : 1. The excreta voided, energy and energy losses by the roosters during collecting period II (24-48hr) were generally higher than those of period I, at though there was no significant difference (P>.05). 2. There was not found correlationship between body weight (X) and excreta voided, energy and nitrogen losses IY) (P>.05). The fact supported that body weight of birds did noy affect the losses of FEm+UEe by adult rooster. 3. The feeding of glucose and mixture (corn starch+glucose) decresed excreta voided, energy and nitrogen losses significantly (P<.05) comparing with those of unfed birds. 4. The excreta voided, and nitrogen loss of birdsfed corn starch were much lower thu those of unfed birds. Fact that FEm+UEe losses was not significantly different (P>.05) between birds fed corn starch and unfed birds was indicative that apparent digestibility of corn starch was much lower than that of glucose ana mixture. 5. Nitrogen loss of fed birds was greatly reduced comparing with that of fed birds. The finding was indicative that the carbohydrates input was ultilized to supplemented energy loss through the catabolism of body tissue during fasting.

  • PDF

Single-Phase Bridgeless Zeta PFC Converter with Reduced Conduction Losses

  • Khan, Shakil Ahamed;Rahim, Nasrudin Abd.;Bakar, Ab Halim Abu;Kwang, Tan Chia
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.356-365
    • /
    • 2015
  • This paper presents a new single phase front-end ac-dc bridgeless power factor correction (PFC) rectifier topology. The proposed converter achieves a high efficiency over a wide range of input and output voltages, a high power factor, low line current harmonics and both step up and step down voltage conversions. This topology is based on a non-inverting buck-boost (Zeta) converter. In this approach, the input diode bridge is removed and a maximum of one diode conducts in a complete switching period. This reduces the conduction losses and the thermal stresses on the switches when compare to existing PFC topologies. Inherent power factor correction is achieved by operating the converter in the discontinuous conduction mode (DCM) which leads to a simplified control circuit. The characteristics of the proposed design, principles of operation, steady state operation analysis, and control structure are described in this paper. An experimental prototype has been built to demonstrate the feasibility of the new converter. Simulation and experimental results are provided to verify the improved power quality at the AC mains and the lower conduction losses of the converter.