• Title/Summary/Keyword: Energy loss reduction

Search Result 340, Processing Time 0.022 seconds

Development of Boost Chopper with Built New Renewable Energy in Grid-Connected Distributed Power System (승압 초퍼 기능이 내장된 새로운 태양광 발전용 파워컨디셔너의 개발)

  • Mun, Sang-Pil;Lee, Su-Haeng;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.361-367
    • /
    • 2014
  • This paper is related to a new solar power conditioner for a built-in step-up chopper function. In the first step-up chopper proposed solar PV power conditioner for mutually connected in series with the input voltage of the bypass diodes are respectively connected to the positive terminal should install the mutual boosting chopper diode connected in series with the boost chopper switching element between the two power supply and at the same time the first and the second was connected to a second diode and a resonance inductor and a snubber capacitor in series with each other. And the common connection point between the bypass diode and the step-up chopper and the step-up chopper diode common connection point of the switching elements of the input voltage was set to the boost inductor for storing energy. In addition, between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point of the first auxiliary diode and the second common connection point of the auxiliary diode was provided, the resonance capacitor. Between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point and the common connection point of the resonance inductor snubber capacitor and connecting the third secondary diode, between two power supply lines is characterized by configuring the DC link capacitor bus lines in parallel. Therefore, it is possible to suppress the switching loss through, DC link bus lines, as well as there could seek miniaturization and weight reduction of the power conditioner itself by using a common capacitor of the non-polar non-polar electrolytic capacitor having a capacitor, the service life of the circuit can be extended and it is possible to greatly reduce the loss can be greatly improve the reliability of the product and the operation of the product itself.

Pressure loss coefficient measurements of pyrostarter filters (파이로스타터용 필터 압력손실계수 측정)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.126-133
    • /
    • 2007
  • An experimental apparatus has been designed and prepared in order to measure a pressure loss coefficient of hydropneumatic components, which is an important parameter in a hydropneumatic system Blow-down system has been adopted for the experimental apparatu to meet the high flow energy requirement as well as the apparatus safety. Especially, pressure loss coefficient measurements of pyrostarter filters have been performed and the pressure loss coefficient, K of CQSF has been experimentally acquired. Then it is shown that the turbine inlet pressure $p_2$, which is predicted from the measured K, is in accord with the results of combustion tests. Moreover, the relation between K and combustion pressure $p_0$ has been presented and it is disclosed that the relation accords well with the results of combustion tests. It is anticipated that K of a filter could play a role in PS size reduction by rising up the combustion pressure resulting in increasing the burning rate of solid propellant.

  • PDF

Study on the Core Loss Improvement of SiFe Plate in Relation with Laser Pulse Width in the Laser Scribing (레이저 스크라이빙에 있어서 레이저의 펄스폭에 따른 규소강판의 코어손실 개선 연구)

  • Ahn, Seung-Joon;Park, Chul-Geun;Ahn, Seong-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.320-324
    • /
    • 2005
  • The core loss of $3\%$ SiFe is strongly dependent on silicon content, impurities, permeability, and domain structure of the SiFe. Domain refining has been proved to be very good method for reduction of core loss in high permeability grain oriented SiFe, and laser scribing is well-blown as an effective and industrially important method of domain refinement. In this work, magnetic domain refinement has been carried out by using a pulsed Nd : YAG laser, and the core losses have been measured and analyzed to and optimal parameters of the laser treatment. The laser hem was focused with a spot size of $100{\mu}m$ and pulse energy of 10${\~}$35mJ and the lines were scribed with a period of ${\~}$5mm. The core loss was improved up to $17\%$ with 30 ns-Nd : YAG laser beam in $3\%$ SiFe.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

Effect of dietary energy levels and phase feeding by protein levels on growth performance, blood profiles and carcass characteristics in growing-finishing pigs

  • Hong, J.S.;Lee, G.I.;Jin, X.H.;Kim, Y.Y.
    • Journal of Animal Science and Technology
    • /
    • v.58 no.10
    • /
    • pp.37.1-37.10
    • /
    • 2016
  • Background: Providing of insufficient nutrients limits the potential growth of pig, while feeding of excessive nutrients increases the economic loss and causes environment pollution. For these reasons, phase feeding had been introduced in swine farm for improving animal production. This experiment was conducted to evaluate the effects of dietary energy levels and phase feeding by protein levels on growth performance, blood profiles and carcass characteristics in growing-finishing pigs. Methods: A total of 128 growing pigs ([Yorkshire ${\times}$ Landrace] ${\times}$ Duroc), averaging $26.62{\pm}3.07kg$ body weight, were assigned in a $2{\times}4$ factorial arrangement with 4 pigs per pen. The first factor was two dietary energy level (3,265 kcal of ME/kg or 3,365 kcal of ME/kg), and the second factor was four different levels of dietary protein by phase feeding (1growing(G)-2finishing(F) phases, 2G-2F phases, 2G-3F phases and 2G-3F phases with low CP requirement). Results: In feeding trial, there was no significant difference in growth performance. The BUN concentration was decreased as dietary protein level decreased in 6 week and blood creatinine was increased in 13 week when pigs were fed diets with different dietary energy level. The digestibility of crude fat was improved as dietary energy levels increased and excretion of urinary nitrogen was reduced when low protein diet was provided. Chemical compositions of longissimus muscle were not affected by dietary treatments. In backfat thickness ($P_2$) at 13 week, pigs fed high energy diet had thicker backfat thickness (P = 0.06) and pigs fed low protein diet showed the trend of backfat thinness reduction (P = 0.09). In addition, water holding capacity was decreased (P = 0.01) and cooking loss was increased (P = 0.07) as dietary protein level reduced. When pigs were fed high energy diet with low subdivision of phase feeding, days to 120 kg market weight was reached earlier compared to other treatments. Conclusion: Feeding the low energy diet and subdivision of growing-finishing phase by dietary protein levels had no significant effect on growth performance and carcass characteristics. Also, phase feeding with low energy and low protein diet had no negative effects on growth performance, carcass characteristics but economical profits was improved.

The Metabolic Effects of Rice Bran and Vegetable Cellulose Supplemented Diets on Albino Rats -Especially on Apparent Digestibility of Intake Nutrients- (미강(米糠)과 야채첨가식이(野菜添加食餌)가 흰쥐의 체내대사(體內代謝)에 미치는 영향(影響)( II ) -열량소의 소화흡수율에 미치는 영향을 중심으로-)

  • Yu, Choon-Hie;Kim, Sook-He
    • Journal of Nutrition and Health
    • /
    • v.10 no.3
    • /
    • pp.10-24
    • /
    • 1977
  • The effects of dietary cellulose to utilize the intake nutrients in the albino rats were investigated by the two consecutive experiments in this study. The author wanted to observe the effects of the age of animals and different level of dietary cellulose, high and low in the first experiment and the effects of dietary cellulose from three different sources, rice bran, vegetable and pure-cellulose at high level in the second experiment. The results were summarized as follows. (1) The obvious effect of dietary cellulose caused to increase feces weight. Consequently apparent digestibilities of intake nutrients in the diet decreased. It was noteworthy that fecal glucose excretion was significantly affected by cellulose intake. Since three nutrients, protein, fat and carbohydrate serve as energy sources in the body, this result can be interpreted to be lowered in the efficiency of energy utilization out of intake from the diet. (2) The nutrients loss due to dietary cellulose resulted in reduction of skeletal muscle and bone weights which lead eventually to affect in reduction of body weight. (3) The effects of dietary cellulose showed differently according to the amount of cellulose ingested, dietary nutrients composition, the kinds of dietary cellulose supplemented and the age of experimental animals. When the intake diet was proportionately imbalanced in three different energy sources, carbohydrate, fat and protein, the cellulose intake was adversely affected in the utilization of the nutrients in the body. Cellulose from rice bran decreased body weight gain, cellulose from vegetable maintained medium level in body weight and pure-cellulose increased body weight. Growing rats showed more sensitive effects of cellulose tolerance in the body than grown rats in every concerns of this experiment.

  • PDF

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

Effect of Pressure and Solvent Dielectric Constant on the Kinetic Constants of Trypsin-Catalyzed Reaction. (Trypsin 반응에 대한 용매의 유전상수 및 압력의 영향)

  • Park, Hyun;Chi, Young-Min
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Electrostatic forces contribute to the high degree of enzyme transition state complementarity in enzyme catalyzed reaction and such forces are modified by the solvent through its dielectric constant and polar properties. The contributions of electrostatic interaction to the formation of ES complex and the stabilization of transition state of the trypsin catalyzed reaction were probed by kinetic studied with high pressure and solvent dielectric constant. A good correlation has been observed between the increase of catalytic efficiency of trypsin and the decrease of solvent dielectric constant. Activation volume linearly decreased as the dielectric constant of solvent decreased, which means the increase in the reaction rae. Moreover, the decrease of activation volume by lowering the solvent dielectric constant implies a solvent penetration of the active with and a reduction of electrostatic energy for the formation of dipole of the active site oxyanion hole. When the 야electric constant of the solvents was lowered to 4.7 unit, the loss of activation energy and that of free energy of activation were 2.262 KJ/mol and 3.169 KJ/mol, respectively. The results of this study indicate that the high pressure kinetics combined with solvent effects can provide unique information on enzyme reaction mechanisms, and the controlling the solvent dielectric constant can stabilize the transition state of the trypsin-catalyzed reaction.

  • PDF

Thermo-economic approach for absorption air condition onboard high-speed crafts

  • Seddiek, Ibrahim S.;Mosleh, Mosaad;Banawan, Adel A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.460-476
    • /
    • 2012
  • High-speed crafts suffer from losing a huge amount of their machinery energy in the form of heat loss with the exhaust gases. This will surely increase the annual operating cost of this type of ships and an adverse effect on the environment. This paper introduces a suggestion that may contribute to overcoming such problems. It presents the possibility of reusing the energy lost by the ships' exhaust gases as heating source for an absorption air condition unit onboard high-speed crafts. As a numerical example; the proposed method was investigated at a high-speed craft operating in Red Sea between Egypt and the Kingdom of Saudi Arabia. The results obtained are very satisfactory. It showed the possibility of providing the required ship's air condition cooling load during sailing and in port. Economically, this will reduce the annual ship's operating cost. Moreover, it will achieve a valuable reduction of ship's emissions.

The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies (공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가)

  • Lee, Yun-Sang;Seo, Jung-Youl;Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.