1MW급 풍력 터빈 블레이드의 허브 및 드라이브 트레인 공력 하중 해석 (Aerodynamic Load Analysis at Hub and Drive Train for 1MW HAWT Blade)

  • 조봉현;이창수;최성옥;유기완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.25-32
    • /
    • 2005
  • The aerodynamic loads at the blade hub and the drive shaft for 1MW horizontal axis wind turbine are calculated numerically. The geometric shape of the blade such as chord length and twist angle can be obtained fran the aerodynamic optimization procedure. Various airfoil data, that is thick airfoils at hub side and thin airfoils at tip side, are distributed along the spanwise direction of the rotor blade. Under the wind data fulfilling design load cases based on the IEC61400-1, all of the shear forces, bending moments at the hub and the low speed shaft of the drive train are obtained by using the FAST code. It shows that shear forces and bending moments have a periodic. trend. These oscillating aerodynamic loads will lead to the fatigue problem at both of the hub and drive train From the load analysis the maximum shear forces and bending moments are generated when wind turbine generator system operates in the case of the extreme speed wind condition.

  • PDF

풍력발전기용 800kW급 직접구동형 발전기 개발 (Development of 800kW class Direct Drive Synchronous Generator for WECS)

  • 이홍기;김동언;서형석;한홍식;정영규;이월우;박기현;정진화;임민수;오만수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.76-79
    • /
    • 2005
  • 포항풍력에너지연구소와 (주)보국전기는 에너지 관리공단의 지원으로 2002년부터 직접구동형 풍력터빈( KBP-750D) 에 사용될 발전기 개발을 시작하여 2005년 3월 개발을 완료하였다. KBP-750D에 사용되는 발전기는 증속을 위한 gearbox를 사용하지 않는 직접 구동형이고, 영구자석을 사용하여 여자하는 형식이다. 이런 특징은 풍력발전에서 요구하는 주요 요구조건인 고 효율, 고 신뢰성을 만족시키기 위해서 매우 중요하다. 개발된 발전기는 25 rpm 에서 800 kW의 정격을 가지도록 설계되었다. 공극 직경은 3,320mm 이며, stator의 길이는 705mm, 공극은 4.5mm 이고, 극수는 84이다. 또한 전체 중량은 약 22 ton이다. 이 논문에서는 발전기의 물리설계, 공학설계, 제작 및 시험결과에 관해서 기술한다.

  • PDF

신개념 하이브리드 동력장치 개발 (Development of a new hybrid power system)

  • 김남욱;윤영민;하승범;임원식;박영일;이장무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.533-536
    • /
    • 2005
  • In this paper, a new drive system(SHS) for hybrid electric vehicle is proposed. As dual rotor hybrid electric vehicle using planetary gearsets, the SHS has the advantages of both series and parallel systems. The output speed and torque of SHS can be determined at specific point regardless of the engine's operating point. When the size of generator which is used in SHS is same as in THS, the SHS has more activities of engine control due to the ability that is operated in lower speed range. To maximize the performance of system, we carried out optimization for the three parameters that are engine, motorl and motor2. As the result of the optimization, we confirmed the SHS is more preferable to THS in fuel consumption and acceleration area.

  • PDF

IEC 규격에 따른 풍력 터빈 소음의 현장 실증 (Field Test and Evaluation of Wind Turbine Noise according to IEC Standards)

  • 정철웅;정성수;정완섭;신수현;전세종;이생희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

운전 온도에 따른 열전발전 모듈의 전기적 내부 저항 변화에 대한 연구 (Study on the Variation of Electrical Internal Resistance for Thermoelectric Generator Module with Operating Temperature)

  • 김윤호;김명기;김서영;리광훈;엄석기
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2010
  • An analysis model considered the manufacturing factors and the pellet size has been developed in order to predict the performance characteristics of thermoelectric modules as generators. Since the electrical internal resistance has a significant role in the performance of thermoelectric modules, the variations of electrical internal resistance with operating temperature are experimentally measured. The modified electrical internal resistance calculated from an experimental correlation is applied to the analysis model. To verify the modified analysis model, the output voltage, output current and output power are compared with experimental results for the operating temperature conditions of $T_h=85^{\circ}C$ and ${\Delta}T=40^{\circ}C$. The modified analysis shows a good agreement with the experimental results in terms of the output voltage, current, and power.

그리드/연계선 사고 시 풍력발전단지의 응동 분석 (Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions)

  • 이혜원;김연희;정태영;이상철;강용철
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

양수발전기의 신 효용성 평가 지수 개발 (Development of New Effectiveness Assessment Indices of Pumped Storage Power Plant)

  • 이성훈;최재석;차준민;김남명
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.867-874
    • /
    • 2014
  • The pumped storage power plants have excellent load following characteristics. It can also be committed quickly for synchronous reserve when it is in the generating mode because it can readily increase its generating power and, consequently, increases the overall system reliability. There are strong incentives for standing the system reliability. Additionally, $CO_2$ emission can be typically impacted due to operation of pumped generators. The increase or decrease of $CO_2$ depends on the generation mix. This paper proposes evaluation of reliability, economy and environment of power system considering pumped generator. This paper describes three case studies of the reliability and economy and environment according to capacity factor and storage capacity of pumped generators. The probabilistic production simulation model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model on the $5^{th}$ power plan in Korea.

분산전원의 구성 및 출력 제어 방법에 따른 Droop 계수 설정 방법 (A Method to Determine the Droop Constant of DGs Considering the Configuration and Active Power Control Mode)

  • 안선주;박진우;정일엽;문승일
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1954-1961
    • /
    • 2008
  • Microgrid usually consists of a cluster of distributed generators(DGs), energy storage systems and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents detailed descriptions of two different options for controlling the active power of DGs in the microgrid. One is regulating the power injected by the unit to a desired amount(Unit output power control) and the other is to regulate the flow of active power in the feeder where the unit is installed to a constant(Feeder flow control). Frequency-droop characteristics are used to achieve good active power sharing when the microgrid operates in the islanded mode. The change in the frequency and the active power output of DGs are investigated according to the control mode and the configuration of DGs when the microgrid is disconnected from the main grid. From the analysis, this paper proposes a method to determine the droop constant of DGs operating in the feeder flow control mode. Simulation results using the PSCAD/EMTDC are presented to validate the approach, which shows good performance as opposed to the conventional one.

펄스방사선에 대한 전자장비 방호용 모듈구현 및 기능시험 (Implementation of the Radiation Protection Module for Electronic Equipment from Pulsed Radiation and Its Function Tests)

  • 이남호
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1421-1424
    • /
    • 2013
  • The electronic equipment which is exposed to high level pulsed radiation is damaged by Upset, Latchup, and Burnout. Those damages come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appear as losses of a power in military weapon system or as a blackout in aerospace equipment and eventually caused in gross loss of national power. In this paper, we have implemented a RDC(Radiation detection and control module) as a part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC, which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator, is designed to protect the an important electronic circuits from the a pulse radiation. To verify the functionality of the RDC, LM118s, which had damaged by the pulse radiation, were tested. The test results showed that the test sample applied with the RDC was worked well in spite of the irradiation of a pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with the RDC had the functionality of radiation protection for the electronic devices.

유체 토크 컨버터를 이용한 정회전 정출력 풍력발전시스템 연구 및 개발 (A Study and Development of the Wind Turbine System for Rated Revolutions and Rated Output using Fluid Torque Converter)

  • 이인열;이강일;심충무;최대규;임재규
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.40-47
    • /
    • 2012
  • Most of existing wind turbine system is used with geared type; however, this type has lots of problems which are noisy, weight, maintenance and so on. In this paper, wind turbine system with fluid torque converter applied to solve these problems. In case of the proposed wind turbine system, it is possible to transmit torque to adaptable distance. So various sets including generator, inverter and auxiliary motor move from the nacelle to the ground. As a result, Total weight in Nacelle can be decreased. however, the efficiency can be decreased with fluid torque system. We also applied auxiliary motor to fluid torque system. So, we also realized rated revolutions and rated output windturbine and could get considerable good data.