• Title/Summary/Keyword: Energy extraction efficiency

Search Result 143, Processing Time 0.024 seconds

Estimation of Wave Energy Extraction Efficiency for a Compact Array System of Small Buoys (밀집 배열 부이시스템의 파랑에너지 추출 효율 추정)

  • Choi, Yoon-Rak
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • A compact array system of small buoys is used for wave energy extraction. To evaluate the performance of this system, hydrodynamic analysis is carried out in regular waves using the higher order boundary element method. The motion response of each buoy is calculated considering hydrodynamic interactions caused by other buoys. The effect of energy extraction device is modeled as a linear damping load. The efficiencies of energy conversion are compared using the various sizes and arrangements of the array system and the damping coefficients for energy extraction. The increase in size or the packing ratio of the system gives better efficiency. However, the wave condition and the cost for the system should be considered to optimize performance from the perspective of engineering and economics. The proposed nondimensionalized damping coefficient for energy extraction is 0.1~0.5.

The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System (축열시스템의 온수이용 예측에 관한 연구)

  • Cho, W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

Numerical Investigation of Multi-body Wave Energy Converters' Configuration

  • Heo, Kyeonguk;Choi, Yoon-Rak
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.132-142
    • /
    • 2022
  • We investigate the performance of multi-body wave energy converters (WECs). This investigation considers multiple scattering of water waves by the buoys of a WEC under the generalized mode approach. Predominantly, the effect of a WEC's configuration on its energy extraction is studied in this research. First, single-row terminator and single-column attenuator arrays of vertical cylinders have been studied. The performance of these attenuator arrays shows that the wall effect induced by the periodic buoys influences the wave propagation and energy extraction in these WECs. Further studies show that a single-row terminator array of vertical cylinders performs better than the corresponding single-column attenuator array. Subsequently, multi-row terminator arrays of vertical cylinders are investigated by conducting a parametric study. This parametric study shows that the hydrodynamic property of three resonance phenomena makes energy extraction efficiency drop down, and the magnitude of energy extracted oscillates between the resonance points in these WECs. Finally, a 4×8 terminator array of vertical cylinders is studied to determine the effect of various dx (x-directional distance between adjacent rows) within this WEC on its performance. In particular, this study enforces at least two equal dx values within the 4×8 terminator array of vertical cylinders. It shows that a small value of this dx leads to better energy extraction efficiency in some of these various dx arrays than that of a corresponding regular array with the same dx.

Wave Power Extraction by Strip Array of Multiple Buoys (스트립 배열된 다수 부이에 의한 파력에너지 추출)

  • Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.474-483
    • /
    • 2014
  • The majority of existing WECs (wave energy converters) are designed to achieve maximum power at a resonance condition. In the case of a single WEC, its size must be large enough for tuning, and it has high efficiency only within a limited frequency band. Recently, wave power extraction by deploying many small buoys in a compact array has been studied under the assumption that the buoy's size and separation distance are much smaller than the water depth, wave length, and size of the array. A boundary value problem involving the macro-scale boundary condition on the mean surface covered by an infinite strip of buoys is solved using the eigenfunction expansion method. The energy extraction efficiency (${\varepsilon}=1-R^2_f-T^2_r$), where $R_f$ and $T_r$ are the reflection and transmission coefficients for a strip array of buoys, is assessed for various combinations of packing ratio, strip width, and PTO damping coefficient.

Remediation of benzo[a]pyrene Contaminated Soil using Subcritical Water (아임계수를 이용한 토양 내 벤조[a]피렌 정화)

  • Shin, Moon-Su;Islam, Mohammad Nazrul;Jo, Young-Tae;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.13-17
    • /
    • 2014
  • Subcritical water acts like an organic solvent at elevated temperature in terms of its physicochemical properties. Taking into account this advantage, the remediation experiments of benzo[a]pyrene contaminated soil (8.45 mg/kg of initial concentration) were conducted using subcritical water extraction apparatus. The effect of operating factors on the removal efficiency was studied at the varying the conditions of the water temperature ranging $200{\sim}300^{\circ}C$, extraction time 30~90 min, and flow rate 0.3~2.0 mL/min. 12 g of benzo[a]pyrene contaminated soil was inserted into the extraction cell and placed into the reactor and then the subcritical water was driven through the cell. In this study, the removal efficiency of benzo[a]pyrene was increased from 55.1 to 98.1% when the temperature increased from 200 to $300^{\circ}C$. The removal efficiency was decreased from 97.0 to 77.0% when the flow rate increased from 0.3 to 2.0 mL/min, suggesting that the extraction is limited by intra-particle diffusion. The 30 min reaction time was determined as an effective treatment time at $250^{\circ}C$. Based on the results, the optimum condition for the remediation of benzo[a]pyrene contaminated soil was suggested to be $250^{\circ}C$, 30 min, and 0.3 mL/min.

Microalgal Oil Recovery by Solvent Extraction from Nannochloropsis oceanica (Nannochloropsis oceanica로부터 용매추출법을 이용한 미세조류 오일 회수)

  • Park, Ji-Yeon;Lee, Gye-An;Kim, Keun-Yong;Kim, Ki-Yong;Choi, Sun-A;Jeong, Min-Ji;Oh, You-Kwan
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.88-91
    • /
    • 2014
  • In this study, oil as a source of biodiesel from Nannochloropsis oceanica was extracted using organic solvent. The oil extraction yield and efficiency from dry and wet microalgae were investigated. The initial fatty acids content of the N. oceanica was 317.8 mg/g cell showing a high oil content over 30%. The yield from dry microalgae was higher than that from wet microalgae due to the inhibition of water. The yield by chloroform-methanol was the highest and the yield by hexane was the lowest. However, the total fatty acids contents with the chloroform-methanol were 678.7 and 778.2 mg/g oil under dry and wet conditions, respectively. The high oil extraction yield by chloroform-methanol reflected the fact that the extracted oil contained a high level of impurity. The hexane-methanol extraction from dry N. oceanica showed high oil extraction efficiency, 82.6%. The chloroform-methanol extraction under wet condition also showed high efficiency, 88.0%. While the hexane-methanol extraction from dry microalgae is desirable under low drying cost, the chloroform-methanol extraction from wet microalgae is desirable under high drying cost.

Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers (전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교)

  • Yang, Won Suk;Kim, Young Il;Park, Seung Tae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

Extraction of Phenol from the Contaminated Soil Using Microwave Energy (Microwave Energy를 이용한 오염토양에서 Phenol의 추출)

  • 이기환;이태호;김윤아
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.447-459
    • /
    • 2003
  • This study was carried out to develop an efficient process far the elimination of phenol pollutant from soils. An microwave-assisted process (MAP) and a conventional Soxhlet extraction method (SEM) were employed to extract phenol from two types of soils. The effects of extraction methods, aged time of the spiked soil samples, extraction solvent and extraction time on the extraction performance were compared. Our results demonstrate that the recoveries from standard soil spiked were at least 10% higher fer MAP than these f3r the conventional Soxhlet. The extraction time by MAP requires significantly shelter time (1 min) than 15 h of the conventional Soxhlet. The recoveries from non-contaminated soil spiked with phenol were also almost identical f3r above results. The reduction of the extraction times with efficiency higher than that afforded by the conventional Soxhlet technique supports the suitability of the MAP method.

The development of module for automatic extraction and database construction of BIM based shape-information reconstructed on spatial information (공간정보를 중심으로 재구성한 BIM 기반 형상정보의 자동추출 및 데이터베이스 구축 모듈 개발)

  • Choi, Jun-Woo;Kim, Shin;Song, Young-hak;Park, Kyung-Soon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.81-87
    • /
    • 2018
  • In this paper, in order to maximize the input process efficiency of the building energy simulation field, the authors developed the automatic extraction module of spatial information based BIM geometry information. Existing research or software extracts geometry information based on object information, but it can not be used in the field of energy simulation because it is inconsistent with the geometry information of the object constituting the thermal zone of the actual building model. Especially, IFC-based geometry information extraction module is needed to link with other architectural fields from the viewpoint of reuse of building information. The study method is as follows. (1) Grasp the category and attribute information to be extracted for energy simulation and Analyze the IFC structure based on spatial information (2) Design the algorithm for extracting and reprocessing information for energy simulation from IFC file (use programming language Phython) (3) Develop the module that generates a geometry information database based on spatial information using reprocessed information (4) Verify the accuracy of the development module. In this paper, the reprocessed information can be directly used for energy simulation and it can be widely used regardless of the kind of energy simulation software because it is provided in database format. Therefore, it is expected that the energy simulation process efficiency in actual practice can be maximized.

Thermally Stratified Hot Water Extraction (태양열 온수 저장조의 성층 온수 추출에 관한 연구)

  • Pak, Ee-Tong;Jeong, Un-Chul;Sung, Sang-Woo
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.34-40
    • /
    • 1991
  • Thermal stratification enhancement for the higher extraction efficiency of hot water storage tank was experimentally studied with transparent fiber glass cylindical tank($350{\ell}$, D=516mm, H=1680mm). Height to diameter ratio (H/D =1,2,3), flow rate(Q= 8,10,12LPM), inlet-outlet temperature differences(${\Delta}T=20,25,30^{\circ}C$), and geometry of inlet-outlet port were the parameters. In particular, three kind of distributors were used for geometry of inlet-outlet port. As a result, it was possible to get extraction efficiency of 95% by using the distributor having variable diameter but keeping a constant diameter of perforation. So it is recommendable to design the distributor so that the main pipe decrease in diameter toward the dead end.

  • PDF