• Title/Summary/Keyword: Energy efficiency ratio

Search Result 1,240, Processing Time 0.034 seconds

A new method to convert into seawater heat for the indoor air-conditioning resource (건물의 냉방을 위한 해수열 취득에 관한 실험적 연구)

  • Kim Ki-Cheol;Lee Seong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.883-890
    • /
    • 2005
  • The industrial growth and the raised living quality have led to the massive energy consumption. As a result. the polluted environment and the limited amount of energy resources emerged as serious problems to be resolved in 21st century. Especially, in the case of Korea whose imported energy dependency rate is 98.2$\%$ in 2003 and constantly increasing every rear. more than 24$\%$ of overall energy consumption is for housing and commercial use. In order to cope with the shortage of natural energy resources, it is inevitable to develop alternative sustainable energy resources including seawater heat. so that they can replace existing resources. The heat transfer air velocity 3.5 m/s is proper to consideration with the body the pipe size 200A is more suitable than look due to the air velocity quantify and the ratio of pipe surface area. And the error between experimental data with simulation is below 5.34$\%$ so the suggested equation for calculating heat transfer capacity can be used. Therefore out of many methods utilizing seawater heat. this work Presents the efficiency of using sea water heat as a resource for air-conditioners which can be converted from the outside air through the air-to-heat conversion tube . Consequently. this method provides pretty reasonable energy efficiency.

Dynamic Adjustment Strategy of n-Epidemic Routing Protocol for Opportunistic Networks: A Learning Automata Approach

  • Zhang, Feng;Wang, Xiaoming;Zhang, Lichen;Li, Peng;Wang, Liang;Yu, Wangyang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.2020-2037
    • /
    • 2017
  • In order to improve the energy efficiency of n-Epidemic routing protocol in opportunistic networks, in which a stable end-to-end forwarding path usually does not exist, a novel adjustment strategy for parameter n is proposed using learning atuomata principle. First, nodes dynamically update the average energy level of current environment while moving around. Second, nodes with lower energy level relative to their neighbors take larger n avoiding energy consumption during message replications and vice versa. Third, nodes will only replicate messages to their neighbors when the number of neighbors reaches or exceeds the threshold n. Thus the number of message transmissions is reduced and energy is conserved accordingly. The simulation results show that, n-Epidemic routing protocol with the proposed adjustment method can efficiently reduce and balance energy consumption. Furthermore, the key metric of delivery ratio is improved compared with the original n-Epidemic routing protocol. Obviously the proposed scheme prolongs the network life time because of the equilibrium of energy consumption among nodes.

Exploration of Optimal Multi-Core Processor Architecture for Physical Modeling of Plucked-String Instruments (현악기의 물리적 모델링을 위한 최적의 멀티코어 프로세서 아키텍처 탐색)

  • Kang, Myeong-Su;Choi, Ji-Won;Kim, Yong-Min;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.281-294
    • /
    • 2011
  • Physics-based sound synthesis usually requires high computational costs and this results in a restriction of its use in real-time applications. This motivates us to implement the sound synthesis algorithm of plucked-string instruments using multi-core processor architectures and determine the optimal processing element (PE) configuration for the target instruments. To determine the optimal PE configuration, we evaluate the impacts of a sample-per-processing element (SPE) ratio that is defined as the amount of sample data directly mapped to each PE on system performance and both area and energy efficiencies using architectural and workload simulations. For the acoustic guitar, the highest area and energy efficiencies are achieved at a SPE ratio of 5,513 and 2,756, respectively, for the synthesis of musical sounds sampled at 44.1 kHz. In the case of the classical guitar, the maximum area and energy efficiencies are achieved at a SPE ratio of 22,050 and 5,513, respectively. In addition, the synthetic sounds were very similar to original sounds in their spectra. Furthermore, we conducted MUSHRA subjective listening test with ten subjects including nine graduate students and one professor from the University of Ulsan, and the evaluation of the synthetic sounds was excellent.

Machine-Learning-Based Link Adaptation for Energy-Efficient MIMO-OFDM Systems (MIMO-OFDM 시스템에서 에너지 효율성을 위한 기계 학습 기반 적응형 전송 기술 및 Feature Space 연구)

  • Oh, Myeung Suk;Kim, Gibum;Park, Hyuncheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.407-415
    • /
    • 2016
  • Recent wireless communication trends have emphasized the importance of energy-efficient transmission. In this paper, link adaptation with machine learning mechanism for maximum energy efficiency in multiple-input multiple-output orthogonal frequency division multiplexing(MIMO-OFDM) wireless system is considered. For reflecting frequency-selective MIMO-OFDM channels, two-dimensional capacity(2D-CAP) feature space is proposed. In addition, machine-learning-based bit and power adaptation(ML-BPA) algorithm that performs classification-based link adaptation is presented. Simulation results show that 2D-CAP feature space can represent channel conditions accurately and bring noticeable improvement in link adaptation performance. Compared with other feature spaces, including ordered postprocessing signal-to-noise ratio(ordSNR) feature space, 2D-CAP has distinguished advantages in either efficiency performance or computational complexity.

Effects of Gamma Ray Irradiation on the Struvite Crystallization of Livestock Wastewater (축산폐수를 이용한 스트러바이트 합성에 감마선 조사가 미치는 영향)

  • Yoo, Byeong-Hak;Jo, Seong-Hui;Lee, Myun-Joo;Kim, Tak-Hyun
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.313-317
    • /
    • 2010
  • The struvite crystallization was applied to remove $NH_4{^+}$ in livestock wastewater. The ammonium ions can be very toxic to the aquatic creatures. In this experiments, the livestock wastewater from Gongju livestock wastewater treatment plant was used. The behaviors of various parameters such as pH, mole ratio of $Mg^{2+}$ : $NH_4{^+}$ : $PO{_4}^{3-}$ and reaction temperature for struvite crystallization of livestock wastewater and the effect of gamma ray irradiation were evaluated. As results, for the pH variation, the $NH_4{^+}$ removal efficiency showed the highest, 88%, at pH 9~9.25. The removal efficiency of $NH_4{^+}$, $Mg^{2+}$ and $PO{_4}^{3-}$ was showed highest when same molar ratio of $Mg^{2+}$ and $PO{_4}^{3-}$ were applied. The $NH_4{^+}$ removal efficiency showed 82% at $7^{\circ}C$, and 90% at $30^{\circ}C$ with temperature. When the wastewater was irradiated with 20 kGy of gamma ray, $NH_4{^+}$ was removed as much as 83%.

Clustering Algorithm for Efficient Energy Management in Sensor Network (센서 네트워크에서의 효율적 에너지 관리를 위한 클러스터링 알고리즘)

  • Seo, Sung-Yun;Jung, Won-Soo;Oh, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10B
    • /
    • pp.845-854
    • /
    • 2008
  • In this paper, we propose a clustering algorithm for efficient energy management of sensor network consisted of sensor nodes that have restricted energy to solve these problem. Proposed algorithm improves energy efficiency by controlling sensing power. And it has distinctive feature that is applied in various network environment. The performance evaluation result shows that the energy efficiency is improved by 5% in the case of all sensor node fixed and by $10{\sim}15%$ in the case of all sensor node moving. It is confirmed through experiment process that the proposed algorithm brings energy efficiency ratio improvement of $5{\sim}15%$ more than the existing algorithm. Proposed algorithm derived an upper bound on the energy efficiency for Ubiquitous Computing environment that have various network environment that is with ZigBee technology of IEEE 802.15.4 bases. Also, we can blow bring elevation for lifetime of sensor network greatly for lifetime of sensor node as is small. And we think that may expand practical use extent of a sensor network technology more in fast changed network environment.

An Economical Analysis on Fuel Switching Model of Coal Power Plant using Herbaceous Biomass (초본계 바이오매스 활용 석탄발전소 연료전환 모형 경제성분석 연구)

  • Um, Byung Hwan;Kang, Chan Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.89-99
    • /
    • 2019
  • The project to utilize kenaf as thermal power plant fuel has a positive effect on the unused energy utilization, greenhouse gas reduction, and farm income. However, it is analyzed that it is difficult to secure economical efficiency because the fuel cost of kenaf is higher than that of power by thermal power plant and Renewable Energy Certification (REC). The project of power generation using kenaf is meet the government's major policies, while government support is essential for securing economical efficiency. As a result of the sensitivity analysis on the ratio of the government subsidies, to secure economical efficiency, the power generation prices using kenaf through the direct financial support of the government indicate that 47% and 76% of kenaf fuel cost are supported by government in case of the Saemangeum reclamation and Gangneung-si, respectively. In the case of the government indirect policy support, if kenaf is included as a renewable energy source of Renewable Energy Portfolio Standard and REC is granted, the economic efficiency of Saemangeum reclamation and Gangneung-si is obtained when REC secured at 1.05 or more and 2.43 or more, respectively. The results of this study are meaningful in that the direct and indirect effects of the government on the development of the herbaceous energy crop, kenaf, were evaluated economically. These results are to suggest the need for demonstration study, but economics analyze and evaluate are necessary based on operational data through the demonstration phase in the future.

The experimental study of 1 ton/day coal gasifier using Adaro coal (1 ton/day 석탄가스화기를 이용한 Adaro 탄의 가스화 특성 실험)

  • Park, Seik;Jung, Jaehwa;Seo, Hai-Kyung;Lee, Joongwon;Ju, Ji-Sun;Ji, Junhwa;Kim, Miyoung;Kim, Kitae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.105.1-105.1
    • /
    • 2010
  • Korea Electric Power Research Institute (KEPRI) has developed a compact coal-gasification system to accumulate our experiment skills. The combustion furnace for residual oil was modified as a small size coal gasifier. Recently, coal feeding system was also upgraded to control coal feed rate more accurately. Our research group has conducted several experiments to find out the effect of $O_2$/coal ratio on the cold gas efficiency. Furthermore, the effect of $N_2$/coal ratio on the transport characteristics was also studied. According to the calculation of heat and mass balance, the cold gas efficiency was estimated to the maximum at $O_2$/coal ratio of around 0.73. But small size gasifier such as ours required higher value of $O_2$/coal ratio than that of the theoretical estimation. On the optimal $N_2$/coal ratio, we noticed that the coal feed rate was intimately related with the transporting gas pressure and the pipe diameter.

  • PDF

Dynamic Analysis of PEM fuel cell system (PEM 연료전지시스템의 동특성 해석)

  • Kim Beomsoo;Jeon Soonil;Lim Wonsik;Park Yeong-il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.353-356
    • /
    • 2005
  • We developed a dynamic model of PEM fuel cell system which can analyze its transient response to dynamic load current. System components such as compressor, air cooler, humidifier, and stack were modeled based on their dynamic equations and performance maps by using Matlab Simulink platform. Through this simulation model, dynamic characteristics of fuel cell system including oxygen excess rat io, stack voltage, and system efficiency were shown. In addition to that, we briefly analyzed the humidity effect on cathode pressure and system efficiency, expecting that this model can be further used to optimize fuel cell system parameters just like operating pressure and temperature, humidity and oxygen excess ratio.

  • PDF

Development and efficiency evaluation of 30kW scale syngas cogeneration system (30kW 급 합성가스 열병합 시스템 개발 및 효율 성능평가)

  • Park, Il-Gun;Kim, Sang-Tae;Noh, Gwi-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1427-1433
    • /
    • 2019
  • In this paper, Gas engine was tested for the energy of synthesis gas. As excess air ratio increase 1, 1.1, 1.2, 1.3, 1.4, 1.5, 1.6 in 1800 rpm and synthesis gas, thermal efficiency generally decrease and power generation was 34 kWm at λ 1.4. And excess air ratio increase 1, 1.1, 1.2, 1.3, 1.4 in power generation 34 kWm, thermal efficiency generally increase 34.2%, 36.9%, 37.2%, 37.4%, 38.1%. Total efficiency through power generation consumes 38.7 kg/h of fuel at 30 kWe load and recovers 57.3% of waste heat by recovering 57.3 kW of waste heat through 32.1% power generation efficiency and heat recovery from cooling water and exhaust gas. The total efficiency was 85.8%.