• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 863, Processing Time 0.032 seconds

Economic Evaluation of Domestic Photobiological Hydrogen Production (국내 광생물학적 수소생산의 경제성 평가)

  • Gim, Bong-Jin;Kim, Jong-Wook
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • This paper deals with an economic evaluation of domestic photobiological hydrogen production. We evaluate the economic feasibility of domestic photobiological hydrogen production utilizing green algae and cyanobacteria. In addition, we make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the price of a photo-bioreactor and the value of solar to hydrogen efficiency. The estimated hydrogen production price of the two-step indirect biophotolysis was 12,099won/kg$H_2$. It is expected that the hydrogen production price by the two-step indirect biophotolysis can be reduced to 2,143won/kg$H_2$ if the solar to hydrogen efficiency is increased to 10% and the price of a photo-bioreactor is decreased to $25/$m^2$. The two-step indirect biophotolysis is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen efficiency and to reduce the prices of the photo-bioreactor and system facilities.

Design and Performance Evaluation for a Fuel Cell/Battery Hybrid Mini-Bus Based on a Simulation (시뮬레이션 기반 연료전지/2차전지 하이브리드 미니버스의 설계 및 성능 평가)

  • Kim, Min-Jin;Kong, Nak-Won;Lee, Won-Yong;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.1
    • /
    • pp.60-66
    • /
    • 2007
  • In terms of the vehicle efficiency, a fuel cell hybrid system has advantages compared to a conventional internal combustion engine and a fuel cell alone-powered system. The efficiency of the fuel cell hybrid vehicle mainly depends on the maximum power of the fuel cell and therefore it is important to decide the design value of the fuel cell maximum power. In this paper, to estimate the performance of the fuel cell hybrid mini-bus in the design phase the simulator based on the models for the fuel cell stack, the electric battery, the fuel cell balance of plant, the controller, and the vehicle itself is proposed. Additionally, the hybrid mini-bus efficiencies with several different fuel cell powers are simulated for a city driving schedule and are compared on another. Consequently, the proposed simulation scheme is useful to determine the best design value of the fuel cell hybrid vehicles.

Performance Evaluation and Analysis for Discrete Wavelet Transform on Many-Core Processors (매니코어 프로세서 상에서 이산 웨이블릿 변환을 위한 성능 평가 및 분석)

  • Park, Yong-Hun;Kim, Jong-Myon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.5
    • /
    • pp.277-284
    • /
    • 2012
  • To meet the usage of discrete wavelet transform (DWT) on potable devices, this paper implements 2-level DWT using a reference many-core processor architecture and determine the optimal many-core processor. To explore the optimal many-core processor, we evaluate the impacts of a data-per-processing element ratio that is defined as the amount of data mapped directly to each processing element (PE) on system performance, energy efficiency, and area efficiency, respectively. This paper utilized five PE configurations (PEs=16, 64, 256, 1,024, and 4,096) that were implemented in 130nm CMOS technology with a 720MHz clock frequency. Experimental results indicated that maximum energy and area efficiencies were achieved at PEs=1,024. However, the system area must be limited 140mm2 and the power should not exceed 3 watts in order to implement 2-level DWT on portable devices. When we consider these restrictions, the most reasonable energy and area efficiencies were achieved at PEs=256.

The Operation Characteristics of Domestic 1kW Gas Fueled Internal Combustion Engine Cogeneration System (1kW급 가스엔진 열병합발전시스템 성능특성에 관한 연구)

  • Choi, Jae-Joon;Park, Byung-Sik;Jung, Dae-Heon;Im, Yong-Hoon;Choi, Young-Ho;Song, Dae-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.321-324
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and recently, the household cogeneration system has been the center object of attention because of the loss of power transmission and the reasonable energy consumption relative to the household (condensing) boiler producing heat only. A tiny, 1kW of electrical output, gas fueled internal combustion engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. With the emission characteristics, the cogeneration system was analyzed. It was showed the gas engine cogeneration system produced the lowest NOx level compared any other cogeneration system due to the three-way catalyst.

  • PDF

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF

PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method (IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구)

  • Pak, Jin-Woo;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

A study on economic evaluation when renewable energy system is introduced in public buildings inside of Daegu Sin-seo innovation city (대구신서혁신도시 내 공공건축물의 신재생에너지 시스템 도입시 경제성 평가에 관한 연구)

  • Kim, Bo-Ra;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.175-180
    • /
    • 2009
  • According to an increasing demand of political support and development on renewable energy as a solution for the energy problem in Korea, the government has established a goal to raise renewable energy supply from 2.27% to 5% until 2011. Especially in the case of public building in which energy use is in great demand, it would bring a great advantage to develop and utilize the Photovoltaic System as an electric energy and Geothermal Heat Pump System as a thermal energy. On the occasion of Photovoltaic System, Photovoltaic module can be used as an architectural material so that it can reduce construction cost and when we use solar energy, it is possible to make building's own power supply. As for Geothermal Heat Pump System, It can be used infinitely as long as the solar energy exist and operation cost is cheap and yearly efficiency is stable. However, we need to make a plan to reduce early investment expanses for these two renewable energy systems and to expand a diffusion rate as we develop a competitive domestic technology level. So in this study, we are going to perform evaluation of economical efficiency according to the introduction of Photovoltaic System and Geothermal Heat Pump System in public buildings which will be built up inside of Daegu Sin-seo innovation city. As a first step, we will investigate present installation condition of these two renewable energy systems and based upon that, will seek efficient introduction program of renewal energy systems that can be applied in public buildings.

  • PDF

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

Adaptability of Process Evaluation in New and Renewable Energy Dissemination Program (신재생에너지 보급사업 평가에 있어 Process evaluation 적용 가능성 고찰)

  • Kim, Ji-Hyo;Park, Joo-Young;Heo, Eun-Nyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.302-302
    • /
    • 2009
  • 미국 DOE(Department of energy) 산하 EERE(the office of energy efficiency and renewable energy)에서는 시행되고 있는 일반 프로그램 평가(General Program Evaluation) 중 하나인 과정 평가(Process Evaluation)는 프로그램의 수행의 효율성과 유효성을 평가하기 위해 수행된다. EERE에서는 프로그램 별로 매 2~3년에 한번, 프로그램의 진행에 장애요인을 시행하기 위해 부정기적으로 과정평가를 수행하여 프로그램의 진행과정을 개선할 것을 제안하고 있다. 과정평가의 방법론으로는 사례연구(case study), 내용분석(content analysis), 메타평가(meta evaluation), 델파이분석(delphi-analysis), 외부 동료평가(peer review) 등의 방법론이 사용될 수 있다. 특히, EERE는 "Peer Review Guide(2004)"을 발간하여 과정평가에서 있어 외부 동료평가의 방법론을 정리하였다. 과정평가를 통해 프로그램 수행결과의 중간점검과 동시에 프로그램의 발전을 위하 전문가의 제언을 수집할 수 있다. 따라서 과정평가의 결과는 프로그램의 개선에 도움을 줄 수 있으며, 장기 과제인 경우 프로그램 관리에 효과적으로 사용될 수 있다. 우리나라의 경우, 사업 수행 시 '진도보고'나 '중간결과 발표' 등을 통하여 동일한 내용의 평가를 시행하고 있으나, 평가의 항목.시기.예산 등에 대한 지침(guideline)이 구축되었다고 볼 수 없는 상황이다. 한국의 신재생에너지 보급사업은 국가적인 중요도, 투입예산의 규모 및 수행기간 등을 고려할 때 과정평가를 통해 정기적으로 사업의 진행과정을 점검할 필요가 있다 하겠다. 따라서 신재생에너지 분야의 사업의 관리에 적용될 수 있는 EERE의 과정평가를 한국의 상황에 맞게 수정하고 이를 정규적으로 시행하는 방안에 대한 논의가 필요하다 하겠다.

  • PDF

Improvement of Energy Efficiency in Wood Frame House with Energy Efficient Methods (건물 에너지 절약요소 적용을 통한 목조주택의 에너지 성능 개선)

  • Kim, Sejong;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.77-86
    • /
    • 2013
  • This research was carried out to evaluate and raise the energy efficiency of wood frame house. The commercial solution program CE3 (Construction Energy Efficiency Evaluation) was used for simulating the energy consumption in the single-family wood frame house. The results showed that the annual heating energy demand of the house was 160 kWh per 1 $m^2$ floor area. In order to decrease the heating energy demand, the following energy efficiency methods were applied to the simulation : a) simplification of building shape, b) decrease of windows area, c) application of high performance windows (with low thermal transmittance) and d) application of heat recovery ventilator. In case of replacement of the windows with high performance one with thermal transmittance 1 $W/m^2{\cdot}K$, the lowest heating demand of 80 $kWh/m^2{\cdot}a$ was obtained. The best combination of methods, application of high performance windows and heat recovery ventilator, showed heating energy demand 34.5 $kWh/m^2{\cdot}a$.