• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 863, Processing Time 0.027 seconds

Study on Evaluation of Energy Efficiency Rating of the Buildings (건축물의 에너지효율등급 평가에 관한 연구)

  • Son, Won-Tug;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.3
    • /
    • pp.65-69
    • /
    • 2012
  • Since 2010, enhancement of the building energy efficiency and certification system and public office building should have been acquiring the first grade of Building Energy Efficiency. The Building Energy Efficiency Rating evaluation tool and Dynamic Analysis Energy simulation program for Building Energy Efficiency are widely used. The suitability to those programs have been discussed as a variety of programs have been used accordingly. In this study, evaluated the characteristic of Building Energy Efficiency Rating tool(ECO2) of the business building. At a result, the variables on the Weather Data, building Profile and building Load property in hourly between those Building Energy Efficiency evaluation tools have different.

An Analysis of Comparison between the Evaluation Tool for Building Energy Efficiency Rating System and Detailed Analysis Programs (건물에너지효율등급 평가도구와 상세해석프로그램의 비교 분석)

  • Lee, Jae-Hyuk;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.3-8
    • /
    • 2009
  • Since 2001, the Building Energy Efficiency Rating and Certification System have been implemented in Korea. For rating the energy efficiency performance, the evaluation tool for Building Energy Efficiency Rating System has been used. In this study, the evaluation tool was compared with detailed analysis programs(Trnsys 16, ESP-r) through simulations of heating energy needs for apartment, and we checked the character of the evaluation tool.

  • PDF

Design Approaches and Strategies for Energy Saving of 5-Axis Multi-Functional Machine Tools (5축 복합가공기의 에너지 저감을 위한 기술 및 적용 방안)

  • Kim, James;Kim, Kyung-Dong;Lee, Chan-Hong;Nam, Sung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.467-473
    • /
    • 2013
  • Diverse approaches for reducing the total energy consumption of machine tools have been introduced and developed, to cope with rapid increase of total energy costs in world-wide manufacturing industries. To realize the improvement of the energy efficiency, systematic and integrated strategies must be considered, including energy-saving design, optimized control operation and concrete evaluation of the energy efficiency. This paper proposes key enabling technologies required to improve the energy efficiency of 5-axis multi-functional machining tools, considering both of system design and operation in the real production environments. Related standardized procedures of the energy efficiency evaluation is also represented.

Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus (공기압 구동장치의 에너지효율 평가)

  • Jang, J.S.;Ji, S.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.95-100
    • /
    • 2011
  • In this study, an evaluation equation of energy efficiency of pneumatic driving apparatus is proposed. The evaluation equation is derived from state equation and energy equation of air in a control volume, and, the equation of motion of a moving part of a pneumatic cylinder. As a result, distribution of consumption energy and energy efficiency of pneumatic driving apparatus can be analyzed quantitatively. The effectiveness of the proposed method is proved by a pneumatic cylinder driving apparatus using a meter-out driving method.

A Study on the Two-Mode MPPT Control Algorithm and Efficiency Evaluation Method (Two-Mode MPPT 알고리즘 연구 및 효율평가법)

  • Yu, Gwon-Jong;Kim, Ki-Hyun;Jung, Young-Seok;Kim, Young-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • In this paper described common MPPT(Maximum Power Point Tracking) control algorithm; Constant Voltage Control, P&O(Perturbation and Observation), IncCond(Incremental Conductance), and investigated it's efficiency. Through simulation and efficiency evaluation, analyze the steady/transient states characteristics and efficiency of control algorithms respectively. Also, To high-efficiency proposed Two-mode MPPT control for improve on the existing control algorithm. Moreover, this paper suggested a topology for MPPT measuring efficiency and a method of examination.

  • PDF

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Energy Efficiency Evaluation of IT based Ship Energy Saving System-(2) : Ship Test Results (IT기반의 선박에너지절감시스템 성능평가 방법-(2) : 해상시험 수행 결과)

  • Yoo, Yun-Ja
    • Journal of Navigation and Port Research
    • /
    • v.40 no.4
    • /
    • pp.165-171
    • /
    • 2016
  • SEEMP (Ship Energy Efficiency Management Plan) has entered into force since 2013 for the reduction of GHG emission of operating ships. SEEMP guidelines include the hardware modification or installation of energy-saving device on ship. It also includes software based energy-saving technology such as optimum routing, speed optimization, etc. Hardware based technologies are not easy to apply to ongoing vessel due to the operational restriction. Therefore, IT based energy-saving technology was applied and its energy efficiency was evaluated using before and after energy-saving system applied voyage data. SEEMP advises a voluntary participation of EEOI (Ship Energy Efficiency Operation Indicator) use as an indicator of ship energy efficiency operation, and those results were also shown to evaluate the improvement efficiency of energy-saving system.

A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment - (사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 -)

  • Lee, Seon-Dong;Yoo, Ho-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.

A Study on the Evaluation of Energy Consumption of the Air Compressor (공기압축기 소비에너지 평가에 관한 연구)

  • Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.38-44
    • /
    • 2020
  • Various efforts have been initiated to reduce the energy consumption of the compressor as it is one of the approaches to saving a large portion of the fixed cost of the production site. Various results of reducing the energy consumption of the compressor have been reported, but to reduce the energy consumption of the compressors fundamentally, regular management of the compressor should ensure optimum operation. This requires periodic on-site visits by experts, but is often overlooked as a cost issue, resulting in the use of the compressor in low-efficiency conditions. Thus, it is necessary to develop a low-cost evaluation technology for compressor condition monitoring and efficiency analysis to ensure that the compressor is always driven at the optimum efficiency without imposing undue burden on the compressor user. In this study, a sensor was installed at the inlet, outlet, and power supply of the compressor, and a method for evaluating the energy consumption of the compressor using the minimum sensor was derived. The experimental results are presented to show the validity of the proposed method. It was confirmed that the energy consumption of the compressor can be easily as well as efficiently evaluated by using the method developed in this study.

A Evaluation Analysis on Thermal Performance of High Airtight and Insulated Window of High Efficiency Energy Equipment (고효율에너지기자재 고기밀성 단열창호의 단열성능 평가 연구)

  • Jang, Cheol-Yong;Bang, Joo-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.227-230
    • /
    • 2009
  • Currently the country's foreign energy dependence reaches approximately 97% and the total energy consumption percentage of buildings(commercial and domestic parts) reaches approximately 24%. Building energy saving by enhanced insulation will be very important issue. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. This research used for commercialization and ills semination by basic information through a evaluation on insulation performance of the window of high efficiency energy equipment which can improve the insulation performance.

  • PDF