• Title/Summary/Keyword: Energy efficiency

Search Result 11,087, Processing Time 0.042 seconds

A study on the Distribution Estimation of Residental Refrigerators using Bass Diffusion Model and Economic Analysis Corresponding to Enhancement of Energy Efficiency (Bass 확산모형을 이용한 가정용 냉장고의 보급추정 및 효율향상에 따른 경제성 분석 연구)

  • Baek, Jung-Myoung;Won, Jong-Ryul;Lee, Byung-Ha;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1938-1945
    • /
    • 2008
  • Due to rapid economic growth, the usage of residential cooling electrical appliances such as air conditioners and refrigerators has increased dramatically for the last decades. In other to reduce its energy consumption, the authorities have applied energy efficiency standards for principal appliances, including refrigerator. This paper estimates the distribution of refrigerators using the Bass Diffusion Model and then performs economic analysis corresponding to enhancement of energy efficiency more correctly than existing methods.

The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital (병원건물 분산에너지시스템 도입에 따른 경제성분석)

  • Hong, Won-Pyo;Kim, Hyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

Influence of slot width on the performance of multi-stage overtopping wave energy converters

  • Jungrungruengtaworn, Sirirat;Hyun, Beom-Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.668-676
    • /
    • 2017
  • A two-dimensional numerical investigation is performed to study the influence of slot width of multi-stage stationary floating overtopping wave energy devices on overtopping flow rate and performance. The hydraulic efficiency based on captured crest energy of different device layouts is compared with that of single-stage device to determine the effect of the geometrical design. The results show optimal trends giving a huge increase in overtopping energy. Plots of efficiency versus the relative slot width show that, for multi-stage devices, the greatest hydraulic efficiency is achieved at an intermediate value of the variable within the parametric range considered, relative slot width of 0.15 and 0.2 depending on design layouts. Moreover, an application of adaptive slot width of multi-stage device is investigated. The numerical results show that the overall hydraulic efficiency of non-adaptive and adaptive slot devices are approximately on par. The effect of adaptive slot width on performance can be negligible.

Energy Harvesting Efficiency Enhancement by Optimal Design of PZT and Electric System (PZT 시스템과 전기 시스템의 최적 설계를 통한 Energy Harvesting 효율 향상)

  • Oh, Jae-Eung;Kim, Jin-Su;Jeong, Un-Chang;Yoon, Jung-Min;Roh, Jeong-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.925-926
    • /
    • 2014
  • The purpose of this study is intended to improve the efficiency of energy harvesting through the optimal design of the PZT system and the electrical system. To improve the efficiency of energy harvesting, it is necessary to increase the output voltage generated from the PZT. In this study, first the mounting position and shape of the PZT which is attached to the cantilever were optimized. Second electric circuit was optimized by using a series connection of a circuit and the electrical resonance frequency. As a result, we improve the output voltage about 5V.

  • PDF

A Piezoelectric Energy Harvester with High Efficiency and Low Circuit Complexity

  • Do, Xuan-Dien;Nguyen, Huy-Hieu;Han, Seok-Kyun;Ha, Dong Sam;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.319-325
    • /
    • 2015
  • This paper presents an efficient vibration energy harvester with a piezoelectric (PE) cantilever. The proposed PE energy harvester increases the efficiency through minimization of hardware complexity and hence reduction of power dissipation of the circuit. Two key features of the proposed energy harvester are (i) incorporation synchronized switches with a simple control circuit, and (ii) a feed-forward buck converter with a simple control circuit. The chip was fabricated in $0.18{\mu}m$ CMOS processing technology, and the measured results indicate that the proposed rectifier achieves the efficiency of 77%. The core area of the chip is 0.2 mm2.

The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital (병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

Localized Path Selection Algorithm for Energy Efficiency and Prolonging Lifetime in Ad-Hoc Networks (에드 혹 네트워크에서 에너지 효율성과 네트워크 수명 연장을 위한 지역적 경로 선택 알고리즘)

  • Lee, Ju-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.6
    • /
    • pp.65-72
    • /
    • 2010
  • In ad-hoc network, the technique to efficiently consume the limited amounts of energy is an important issue since the wireless terminal node is operated on batteries as their energy resource. In order to extend the system lifetime, through a balanced energy consumption, we must delay the situation in which a particular terminal node's energy is depleted and results in system disconnection. Also, the link, which has low reliability due to the mobility of the node, should be avoided considering the key element when setting up the route. The proposed CMLR method in this paper enables to increase the efficiency of energy consumption with a new cost function considering the residue energy of node, error rate of link, and transmission energy consumption. This method is extending the network lifetime and increasing the energy efficiency by compromising the value between the minimization of the transmission energy consumption and maximization of the node's lifetime. Through the simulations the proposed CMLR algorithm was verified by showing better performance over the conventional methods in terms of network lifetime and path efficiency.

Domestic Greenhouse Gas Reduction Policy (국내 온실가스 감축 정책)

  • Bae, Sung-Ho
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.8-12
    • /
    • 2011
  • For reducing greenhouse gas emissions, the short-term strategy is of existing energy-efficient appliances to facilitate the spread of energy efficiency improvements to improve energy efficiency, energy saving projects that will include investments to enable. R&D is at the core of the long-term strategy. To reduce energy demand, the equipments and processes improved energy efficiency should be developed. In terms of energy supply, the policies for greenhouse gas reduction is to replace fossil fuels by expanding the supply of renewable energy such as solar, wind, geothermal, biomass and nuclear power as nearly zero-emission of greenhouse gas. In terms of energy consumption, measures to reduce greenhouse gas emissions is in line with the policy for efficiency improvement. The buildings & work-site of high-energy consumption in the building & Industry sectors, should implement a policy to strengthening the voluntary agreement on energy-saving facilities and expand to invest in energy saving facilities.

The Effectiveness of New Power Generation and Energy Demand Reduction to Achieve Greenhouse Gas Reduction Goals in Building Area

  • Park, Seong-Cheol;Kim, Hwan-Yong;Song, Young-Hak
    • Architectural research
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2016
  • Since the massive power outages that hit across the nation in September 2011, a growing imbalance between energy supply and demand has led to a severe backup power shortage. To overcome the energy crisis which is annually repeated, a policy change for deriving energy supply from renewable energy sources and a demand reduction strategy has become essential. Buildings account for 18% of total energy consumption and have great potential for energy efficiency improvements; it is an area considered to be a highly effective target for reducing energy demand by improving buildings' energy efficiency. In this regard, retrofitting buildings to promoting environmental conservation and energy reduction through the reuse of existing buildings can be very effective and essential for reducing maintenance costs and increasing economic output through energy savings. In this study, we compared the energy reduction efficiency of national power energy consumption by unit production volume based on thermal power generation, renewable energy power generation, and initial and operating costs for a building retrofit. The unit production was found to be 13,181GWh/trillion won for bituminous coal-fired power generation, and 5,395GWh/trillion won for LNG power generation, implying that LNG power generation seemed to be disadvantageous in terms of unit production compared to bituminous coal-fired power generation, which was attributable to a difference in unit production price. The unit production from green retrofitting increased to 38,121GWh/trillion won due to the reduced energy consumption and benefits of greenhouse gas reduction costs. Renewable energy producing no greenhouse gas emissions during power generation and showed the highest unit production of 75,638GWh/trillion won, about 5.74 times more effective than bituminous coal-fired power generation.

Exhaust Gas Emission and Particulate Matter (PM) from Gasoline, LPG and Diesel Vehicle Using Different Engine Oil (가솔린, LPG, 디젤 차량에서 윤활유에 따른 배출가스 및 입자상물질)

  • Jang, Jinyoung;Lee, Youngjae;Kwon, Ohseok;Woo, Youngmin;Cho, Chongpyo;Kim, Gangchul;Pyo, Youngdug;Lee, Minseob
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.144-151
    • /
    • 2016
  • This study effect of engine oils on regulated fuel economy and emissions including particulate matter (PM) to provide basic data for management of engine oil in vehicles. Three engine oils (Group III base oil, Group III genuine oil with additive package and synthetic oil with poly alpha olefins (PAOs)) were used in one gasoline, one LPG(liquefied petroleum gas) and two diesel vehicles. In the case of diesel vehicles, one is a diesel vehicle without DPF (diesel particulate filter) other is a diesel vehicle with DPF. In this study, the US EPA emission test cycle FTP-75, representing city driving, was used. HORIBA, PIERBURG, and AVL gas analyzers were used to measure the fuel economy and regulated emissions such as CO, NOx, and THC. The number of PM was measured using a PPS (pegasor particle sensor). And, the shape of PMs was analyzed by SEM (scanning electron microscope). The effects of oil type on fuel economy, exhaust gas, and PM were not significant because engine oil consumption by evaporation and combustion in the cylinder is very tiny. Fuel and vehicle type were dominant factors in fuel economy and emissions. HC emission from gasoline vehicles was higher than that from other vehicles and NOx emission from diesel vehicles was higher than that from other vehicles. The number of PM was not affected by the engine oil, but by the driving pattern and fuel. The shapes of the PM, sampled from each vehicle using any test engine oil, were similar.