• Title/Summary/Keyword: Energy distribution

Search Result 5,762, Processing Time 0.032 seconds

Formation of Ultra fine Particle by the Polonium-218 Ions under Different Humidity Conditions (다른 습도조건하에서 Po-218 이온들의 극소입자형성에 관한 연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • A number of investigators have reported the formation of the radiolytic ultrafine particles produced by the interaction of ionizing radiation with water vapor. Previous studies have suggested that a very high localized concentration of the OH radical produced by the radiolysis of water can react with trace gas like organic vapors and produce lower vapor pressure compounds that can then nucleate. In order to determine water vapor dependence of the active, positively charged, first radon daughter(Po-218), an experiment was conducted using a well-controlled radon chamber. The activity size distribution of the radon daughter in the range of 0.5-100nm was measured using the parallel graded wire screens system. Measurements were taken for different relative humidity. The resultant activity size distributions were analyzed. The addition of water vapor to the radon carrier gases resulted in the formation of ultrafine particles by OH radicals formed by radon radiolysis. It may be due to the neutralization of charged Po-218 ion with water vapor through the radio lysis.

  • PDF

Thrust Performance and Plasma Acceleration Process of Hall Thrusters

  • Tahara, Hirokazu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.262-270
    • /
    • 2004
  • Basic experiments were carried out using the THT-IV low-power Hall thruster to examine the influences of magnetic field shape and strength, and acceleration channel length on thruster performance and to establish guidelines for design of high-performance Hall thrusters. Thrusts were measured with varying magnetic field and channel structure. Exhaust plasma diagnostic measurement was also made to evaluate plume divergent angles and voltage utilization efficiencies. Ion current spatial profiles were measured with a Faraday cup, and ion energy distribution functions were estimated from data with a retarding potential analyzer. The thruster was stably operated with a highest performance under an optimum acceleration channel length of 20 mm and an optimum magnetic field with a maximum strength of about 150 Gauss near the channel exit and with some shape considering ion acceleration directions. Accordingly, an optimum magnetic field and channel structure is considered to exist under an operational condition, related to inner physical phenomena of plasma production, ion acceleration and exhaust plasma feature. A new Hall thruster was designed with basic research data of the THT-IV thruster. With the thruster with many considerations, long stable operations were achieved. In all experiments at 200-400 V with 1.5-3 mg/s, the thrust and the specific impulse ranged from 15 to 70 mN and from 1100 to 2300 see, respectively, in a low electric power range of 300~1300 W. The thrust efficiency reached 55 %. Hence, a large map of the thruster performance was successfully made. The thermal characteristics were also examined with data of both measured and calculated temperatures in the thruster body. Thermally safe conditions were achieved with all input powers.

  • PDF

Assessment of the Counter-Flow Thrust Vector Control in a Three-Dimensional Rectangular Nozzle (3차원 직사각형 노즐에서 역유동 추력벡터 제어 평가)

  • Wu, Kexin;Kim, Tae Ho;Kochupulickal, James Jintu;Kim, Heuy Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.1
    • /
    • pp.34-46
    • /
    • 2020
  • Computational assessment of gas-dynamic characteristics is explored for a three-dimensional counter-flow thrust vector control system in a rectangular supersonic nozzle. This convergent-divergent nozzle is designed by Method of Characteristics and its design Mach number is specially set as 2.5. Performance variations of the counter-flow vector system are illustrated by varying the gap height of the secondary flow duct. Key parameters are quantitatively analyzed, such as static pressure distribution along the centerline of the upper suction collar, deflection angle, secondary mass flow ratio, and resultant thrust coefficient. Additionally, the streamline on the symmetry plane, three-dimensional iso-Mach number surface contour, and three-dimensional turbulent kinetic energy contour are presented to reveal overall flow-field characteristics in detail.

An Analysis of Inelastic Neutron Scattering by Liquid Methane

  • Chung, Chang-Hyun;Shin, Won-Kee;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.265-278
    • /
    • 1973
  • The incoherent neutron scattering cross section of molecular liquids is analyzed using a damping function model for correlation functions of molecular translations and rotations. The present approach is different from recent works in that the scattering function is evaluated directly, not through the intermediate scattering function. The damping fuction is determined from a simple relation between its long-wavelength limit and the generalized frequency distribution function, and translation-rotation couplings are assumed to be neglected. A physical model is used for the translational motions of center-of-mass of a molecule, including properly its short-time and long-time behaviors. A simple model for the rotational motions is suggested which relates the damping function to the Fourier transform of the dipole correlation function, or equivalently, the infrared vibrational absorption spectrum. Theoretical absolute scattering intensities are computed for liquid methane and shown to be in satisfactory agreement with both thermal and cold neutron measurements.

  • PDF

Stability of Nano-emulsions Containing Fatty Acid and Fatty Alcohol (지방산 및 지방알코올을 함유한 나노에멀젼의 안정성)

  • Cho, Wan Goo;Kim, Kyung Ah;Jang, Seon Il;Cho, Byoung Ok
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.273-279
    • /
    • 2017
  • In this study, low viscous O/W (oil-in-water) nano-emulsion with fatty acid and fatty alcohol was prepared by phase inversion emulsification method using Tween 80 and Span 80 widely used in cosmetic products. The particle size of the nano-emulsion was increased as increasing the concentration of fatty alcohol in oil phase. Adjusting the HLB of mixed surfactants, a stable nano-emulsion with a narrow size distribution was produced. Similar change in viscosity and electrical conductivity in both systems containing fatty acid and fatty alcohol was shown in the vicinity of the phase inversion point. However, high viscosity was shown in a wide range of different aqueous fraction unlike the system consisting only oils and surfactants. The low viscous nano-emulsion with less than 100 nm droplet size was stable for one month or more at room temperature. O/W nano-emulsions with low viscosity containing fatty acid or fatty alcohol produced by low-energy emulsification method can be widely used as formulations of cosmetics.

Study on Development of Flexible Pad for High Speed Train Disk Brake (고속철도 디스크 브레이크의 유연 패드 개발에 대한 연구)

  • Lee, Min-Gyu;Kim, Joo-Yong;Kim, Jae-Min;Yang, Young-Min;Kim, Sang-Ho;Cho, Chong-Du
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.100-108
    • /
    • 2011
  • This paper investigates the structural stability and reliability on improving performance of flexible brake pad used in high speed train. To this end, an improved model of flexible pad was obtained through structural analysis. Brake pad specimens were subjected to modal, stroke and endurance tests to examine the dynamic characteristics and mechanical stability. The hot spot generation with increasing rotational speed was observed on chassis dynamometer equipment and then the structurally uniform contact between the disc and pad was achieved. The temperature distribution of flexible pad was measured using the infrared camcorder. Hence, the proposed flexible pad showed the better structural stability and thermal energy emission.

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Effect of Air Flow Rate on the Performance of Planar Solid Oxide Fuel Cell using CFD (평판형 고체산화물 연료전지의 CFD 성능해석에서 공기유량변화의 영향)

  • Kim, Danbi;Han, Kyoungho;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.4
    • /
    • pp.172-181
    • /
    • 2015
  • Solid Oxide Fuel Cells (SOFC) continue to be among the most promising alternative energy devices. This paper addresses i-V characteristics of SOFC with a focus on air flow rate along the planar anode electrodes. To address this, detailed Butler-Volmer kinetics are implemented in a general-purpose CFD code FLUENT. The numerical results were validated against experimental data from the literature showing excellent match with i-V polarization data ranging 1V-0.4V. Numerical calculations of fuel cell operation under different flow rare conditions were performed in three-dimensional geometries. Results are presented in terms of concentration distribution of hydrogen, oxygen, and water. The simulations and results indicate that advanced CFD with UDF(User-Defined Function) of Butler-Volmer kinetics can be used to identify the conditions leading to air flow rate and specific surface area and guide development of operating conditions and improve the fuel cell system performance.

Nutritional Survey on the School Children Box lunch -Based in K Elementary school children in Seoul- (학령기 아동의 도시락 영양섭취실태에 관한 연구 -서울 K 국민학교를 중심으로-)

  • 이보경
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.4
    • /
    • pp.43-52
    • /
    • 1988
  • This study is intended to reveal the nutritional realities of school children due to their box lunch. The samples were chosen at random from the third grade to the sixth grade children in an elementary school in Seoul : 122 male and 111 female children, 233 children in all. among the subjects, 44.3% have a family of four, 34.3% have over 500,000 won of family income a month, and 44.3% of their mothers graduated from a high school. The average intake of calories is 573.6 Kcal, and the ratios of the calory intakes to the recommended amounts are 90.6% in the third grade children and from the fourth grade to the sixth grade, 79.5% in the male children and 82.9% in the female children. The average consumption of protein is 21.0g and the ratio of animal protein is 41.4%. the ratio of energy yield nutrients is 67.4% : 14.5 : 18.0 (carbohydrate : protein " fat). Considering the recommended amounts, the intake of protein is enough; the consumption of vit, A, thiamine, niacin are appropriate;and the intake of calories, Riboflabin and ascorbic acid, calcium, iron are deficient. Even though there is no significant difference between the socioeconomic factors (the standard of education of the subjects' mothers and family income0 and the intakes of calories and protein, there is a tendency that the consumption of protein intake si more abundant in the middle class than in any other class. The subjects' distribution of the physical growth index, is as follows; A (6.9%), B(19.3%), C(48.5%), D(13.7%) and E (11.6%). As the subjects' intake of calcium increases, the weight shows significant improvement (p<0.001). As the consumption of calories increases, the physical development shows significant improvement (p<0.05), and the weight shows significant increase (p<0.001).

  • PDF

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.