• Title/Summary/Keyword: Energy dependence

Search Result 1,068, Processing Time 0.025 seconds

A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom (말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Kim, Jang-Lyul;Kim, Kwang-Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.263-271
    • /
    • 1996
  • The ANSI N13.32 recommends that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. Gamma dose equivalent conversion and angular dependence factors were calculated by using MCNP code for the case of ANSI N13.32 extremity phantoms(finger and arm) at the depth of $7mg/cm^2$. Those extremity dosimeters were assumed to be irradiated from both monoenergitic photons and ISO X-ray narrow beams. These calculated gamma dose equivalent conversion and angular dependence factors were compared to B. Grosswendt's result calculated by using X-ray beams. The result showed that the dose equivalent conversion factors of this study agreed well with that of B. Grosswendt for all energies within 2% except 7% in the case of the low energies. In the case of angular dependence factors comparison, they agreed within 3%. It was shown that angular dependence factors of the finger phantom decreased as the horizontal angle of the phantom increased for the ISO X-ray beams less than 60keV. For the higher energy X-ray beams range they decreased slightly around 40 degree, but then increased from this energy to 90 degree.

  • PDF

Radiological Characterization of the High-sensitivity MOSFET Dosimeter (고감도 MOSFET 선량계 방사선학적 특성 연구)

  • Cho Sung Koo;Kim Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.215-219
    • /
    • 2004
  • Due to their excellence for the high-energy therapy range of photon beams, researchers show increasing interest in applying MOSFET dosimeters to low- and medium-energy applications. In this energy range, however, MOSFET dosimeter is complicated by the fact that the interaction probability of photons shows significant dependence on the atomic number, Z, due to photoelectric effect. The objective of this study is to develop a very detailed 3-dimensional Monte Carlo simulation model of a MOSFET dosimeter for radiological characterizations and calibrations. The sensitive volume of the High-Sensitivity MOSFET dosimeter is very thin (1 ${\mu}{\textrm}{m}$) and the standard MCNP tallies do not accurately determine absorbed dose to the sensitive volume. Therefore, we need to score the energy deposition directly from electrons. The developed model was then used to study various radiological characteristics of the MOSFET dosimeter. the energy dependence was quantified for the energy range 15 keV to 6 MeV; finding maximum dependence of 6.6 at about 40 keV. A commercial computer code, Sabrina, was used to read the particle track information from an MCNP simulation and count the tracks of simulated electrons. The MOSFET dosimeter estimated the calibration factor by 1.16 when the dosimeter was at 15 cm depth in tissue phantom for 662 keV incident photons. Our results showed that the MOSFET dosimeter estimated by 1.11 for 1.25 MeV photons for the same condition.

  • PDF

Electrical Transport Properties of Gd0.33Sr0.67FeO3 Ceramics (Gd0.33Sr0.67FeO3 세라믹스의 전기전도 특성)

  • Jung, Woo-Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.2 s.285
    • /
    • pp.131-135
    • /
    • 2006
  • In this study, the dielectric, magnetic and transport properties of $Gd_{0.33}Sr_{0.67}FeO_3$ have been analyzed. The dielectric loss anomaly was found to be around 170 K. The activation energy corresponding to relaxation process of this dielectric anomaly was 0.17 eV. From the temperature dependence of the characteristic frequency, we concluded that the elementary process of the dielectric relaxation peak observed is correlated with polaron hopping between $Fe^{3+}\;and\;Fe^{4+}$ ions. The electrical resistivity displayed thermally activated temperature dependence above 200 K with an activation energy of 0.16 eV. In addition, the temperature dependence of thermoelectric power and resistivity suggests that the charge carrier responsible for conduction is strongly localized.

Temperature Dependence Change of Electrical Resistivity on PdHx Films due to Film Thickness Change (PdHx 박막의 두께 변화에 의한 전기비저항의 온도 의존성 변화)

  • Cho, Young-sin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.1
    • /
    • pp.17-22
    • /
    • 1995
  • Thermally evaporated Pd films on substrate were hydrogenated upto 1 bar of hydrogen gas at room temperature. Temperature dependence hange of electrical resistivity on Pd films is examined in the thickness range between $60{\AA}$ and $990{\AA}$. Resistivity of Pd is fitted well with Bloch-$Gr{\ddot{u}}neisen$ formula. Debye temperatures of Pd films are about 254 K, which are 20 K lower than that of bulk Pd. Debye temperature is not sensitive to film thickness change. Temperature of substrate during evaporation changes temperature dependence of resistivity of films much. Optical phonon contribution increases with decreasing temperature of PdHx.

  • PDF

A Study on the Angular Dependence of the PB-3 Dosimeter Using Teledyne 9150 TLD Reader System (열형광선량계(도시메터타입 : PB-3)의 방향의존성에 관한 연구)

  • Son, Jung-Kwon;Kim, Jong-Kyung;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.189-198
    • /
    • 1994
  • An angular dependence experiment was made and a performance test of the Teledyne dosimetry system was done in accordance with the ANSI N13.11-1992. The angular dependence experiment was performed with $^{137}Cs$ and low energy X-ray beam. Teledyne dosimetry system performed well at the $0^{\circ}$ angle of incidence for all dosimeters in both vertical and horizontal irradiations. It would have easily passed the 0.5 tolerance limit. But the dosimetry system was not performed well at the ${\pm}60^{\circ}$ angle of incidence for low energy X-ray beam. The accuracy for $^{137}Cs$ beam at all angles of incidence was within the 0.5 tolerance limit. Therefore performance of the dosimetry system could be considered acceptable in case that the dosimeter is irradiated to $^{137}Cs$ beam. However, it could not be acceptable for the dosimeter irradiated to low energy X-ray, especially at more than ${\pm}40^{\circ}$

  • PDF

Rate-Dependence of Off-Axis Tensile Behavior of Cross-Ply CFRP Laminates at Elevated Temperature and Its Simulation

  • Takeuchi, Fumi;Kawai, Masamichi;Zhang, Jian-Qi;Matsuda, Tetsuya
    • Advanced Composite Materials
    • /
    • v.17 no.1
    • /
    • pp.57-73
    • /
    • 2008
  • The present paper focuses on experimental verification of the ply-by-ply basis inelastic analysis of multidirectional laminates. First of all, rate dependence of the tensile behavior of balanced symmetric cross-ply T800H/epoxy laminates with a $[0/90]_{3S}$ lay-up under off-axis loading conditions at $100^{\circ}C$ is examined. Uniaxial tension tests are performed on plain coupon specimens with various fiber orientations $[{\theta}/(90-{\theta})]_{3S}$ ($\theta$ = 0, 5, 15, 45 and $90^{\circ}C$) at two different strain rates (1.0 and 0.01%/min). The off-axis stress.strain curves exhibit marked nonlinearity for all the off-axis fiber orientations except for the on-axis fiber orientations $\theta$ = 0 and $90^{\circ}$, regardless of the strain rates. Strain rate has significant influences not only on the off-axis flow stress in the regime of nonlinear response but also on the apparent off-axis elastic modulus in the regime of initial linear response. A macromechanical constitutive model based on a ply viscoplasticity model and the classical laminated plate theory is applied to predictions of the rate-dependent off-axis nonlinear behavior of the cross-ply CFRP laminate. The material constants involved by the ply viscoplasticity model are identified on the basis of the experimental results on the unidirectional laminate of the same carbon/epoxy system. It is demonstrated that good agreements between the predicted and observed results are obtained by taking account of the fiber rotation induced by deformation as well as the rate dependence of the initial Young's moduli.

Focusing Geometry Dependence of Single Pass Raman Shifer (단인 통과 라만레이저의 집속 조건에 따른 출력 특성)

  • 고춘수
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.434-441
    • /
    • 1993
  • Focusing geometry dependence of output Stokes energy in single pass methane Raman shifter is investigated. The experimental result shows that the threshold energy decreases as confocal parameter increases. This result can be explained by gain suppression caused by Stokes - anti-Stokes coupling. In this paper, we give simple analysis for the focusing geometry dependence of Stokes - anti-Stokes coupling and present the criterion of confocal parameter to reduce the gain suppression. Focusing geometry dependence of stimulated Brillouin scattering is measured and the result is in good agreement with theoretical prediction.

  • PDF

A Consideration on the Characteristics of Electron Beam Dose Distributions for Clinical Applications (임상적용을 위한 전자선의 선량분포 특성에 대한 고찰)

  • Cha, Dong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2010
  • High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.

  • PDF

Auto-focus Control by Chromatic Filtering in Laser Welding

  • Kim, Cheol-Jung;Baik, Sung-Hoon;Kim, Min-Suk;Chung, Chin-Man;Kim, Kwang-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.94-99
    • /
    • 2000
  • Optical monitoring using the chromatic aberration of focusing optics is applied to auto-focus control in laser welding. The spectral transmittance of thermal radiation from a weld pool through an aperture depends on the wavelength of the spectral band and on the distance of the weld pool from the focusing optics. Its dependence has been used to monitor the focus shift in laser welding by measuring the spectral band signals filtered by the aperture. The difference between pulsed and continuous laser welding is analyzed. Furthermore, the dependence of the focus shift monitoring on the weld pool size variation is optimized to monitor the focus shift independently from the laser power change at the weld pool. The performance of the auto-focus control with chromatic filtering is presented for pulsed laser welding.