• Title/Summary/Keyword: Energy consumptions

Search Result 182, Processing Time 0.022 seconds

The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System (냉방시스템의 운전조건에 따른 에너지 소비특성 연구)

  • Park, Gi-Tae;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facilities (향온시설물에 대한 현열 및 잠열 에너지 회수시스템의 성능해석)

  • 박병규;김무근;김근오
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1057-1065
    • /
    • 2000
  • A sizing of sensible and latent energy recovery system with condensing heat exchanger is important to the design of a thermally controlled facilities. The transient system simulation program TRNSYS 14.2/IISiBat has been used to evaluate the energy consumptions of a thermally controlled facilities which consist of boiler, chiller and condensing heat exchanger, The boiler and chiller are selected based on the annual peak loads and controlled to maintain the setting temperature of $14~17^{\circ}C$. Simulation shows that the amount of sensible and latent energy recovered by heat exchanger is almost 20% of total heating load.

  • PDF

ePRO-OMP: A Tool for Performance/Energy PRofiler and Analyzer for OpenMP Applications (ePRO-OMP: OpenMP 응용 프로그램의 성능 및 에너지 분석 도구)

  • Lee, Young-Ho;Kim, Jihong
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.5
    • /
    • pp.287-293
    • /
    • 2011
  • As chip multiprocessors have been widely adopted in embedded systems, achieving both high performance and low power consumptions of parallel applications becomes challenging. In order to meet these requirements, it is crucial for developers to analyze the performance and energy consumption of parallel applications. In this paper, we propose a tool for profiling and optimizing the performance and energy consumption of OpenMP applications (energy PROfiler and analyzer for OpenMP: ePRO-OMP). The main advantage of ePRO-OMP is that it can analyze both the performance and energy consumption of each parallel region of an OpenMP application, which can help developers find the bottleneck of parallel applications in detail.

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

Energy-Efficient Last-Level Cache Management for PCM Memory Systems

  • Bahn, Hyokyung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.188-193
    • /
    • 2022
  • The energy efficiency of memory systems is an important task in designing future computer systems as memory capacity continues to increase to accommodate the growing big data. In this article, we present an energy-efficient last-level cache management policy for future mobile systems. The proposed policy makes use of low-power PCM (phase-change memory) as the main memory medium, and reduces the amount of data written to PCM, thereby saving memory energy consumptions. To do so, the policy keeps track of the modified cache lines within each cache block, and replaces the last-level cache block that incurs the smallest PCM writing upon cache replacement requests. Also, the policy considers the access bit of cache blocks along with the cache line modifications in order not to degrade the cache hit ratio. Simulation experiments using SPEC benchmarks show that the proposed policy reduces the power consumption of PCM memory by 22.7% on average without degrading performances.

An Analysis on CO2 Emission and Cost Effects of Hydrogen Energy in Sedan Sector (수소에너지의 승용차부문 도입에 따른 CO2 배출 감축 및 비용효과 분석 연구)

  • Hong, Jong-Chul;Kang, Seung-Jin;Choi, Sang-Jin;Park, Sang-Young;Kim, Jong-Wook
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.1
    • /
    • pp.9-21
    • /
    • 2009
  • As one of the alternative solution for energy and environmental issues such as climate change, energy security, oil price, etc., hydrogen energy has been getting so much attentions these days. This paper analyzed the $CO_2$ emission, costs, and energy consumptions when the hydrogen energy was introduced to transportation, specifically in Sedan sector using the energy system model, MARKAL. As results, 21.5% of $CO_2$ emission in 2040 could be reduced and additional 76 billion dollars will be needed in the high energy price scenario. The amount of energy saving mainly due to the replacement of existing car to hydrogen vehicle was 16% of the final energy consumption in 2040.

Evaluation on the Fuel Efficiency of Hi-Pass System (고속도로 하이패스 시스템의 연료감소효과 평가)

  • Lee, Seong-Kwan Mark;Lee, Ki-Young;Choi, Yoon-Hwan;Kwak, Jin-Ho;Sung, Ji-Na
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2010
  • Around a toll plaza, vehicles do such maneuvers as slow down, stop, and speed up to pay their tolls when they use ordinary toll gates. They can be expected more fuel consumptions compared to the vehicles which use the Hi-pass, a Korean type of Electronic Toll Collection System(ETCS). To measure the exact amount of difference between the two gas consumptions, we equipped a test vehicle with a measurement system and constructed a model toll gate on our test field. Through the field tests on fuel consumptions, we could confirm a 36.7 % of energy saving when the test car used the Hi-pass. Then we projected the result on the total traffic volumes which had used national expressway network for five months from January 2009. Projected to the whole traffic, potential cost savings reached 5.34 billion won. We expect this result be frequently mentioned of to prove the fuel efficiency of the Hi-pass system.

Trend and Prediction of Environmental Resources Consumption in the Korean Peninsula (한반도 단위의 환경자원 소비량 추이와 예측)

  • Yeo, Min Ju;Kim, Yong Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.261-279
    • /
    • 2016
  • Trends of food and energy consumptions in South Korea, North Korea, and the Korean Peninsula were shown and consumptions of food and energy for the integrated Korean Peninsula with several Cases were predicted, and the directions for the environmental resources management were suggested in this study. The Food Supply Quantity, the Protein Supply Quantity, and the Food Supply of North Korea were less than those of South Korea, the Eastern Asia, and World after 1990s. However, it is expected that the food consumption in North Korea will increase, if two Koreas are integrated. If the Food Supply Quantity of North Korea is the same as that of South Korea with the maximum projected population of integrated two Koreas by 2055, the food consumption in the Korean Peninsula would increase by 25% compared with the 2011 food consumption of integrated two Koreas. Thus, the choice of diet should be carefully considered and the increase of agricultural productivity is required. Energy consumption in North Korea is very small comparing to that of South Korea and fraction of coal in energy usage of North Korea is very high. If the energy consumption per capita of North Korea after integration be the same as that of South Korea in 2011, the energy consumption in the Korean Peninsula would increase by 45% compared with the 2011 energy consumption of integrated two Koreas. To minimize the environmental effects caused by energy consumption, the energy plan with the reduced fraction of coal in energy supply of North Korea should be adopted and advanced technology with higher efficiency should be applied to establish or expand the energy facility in North Korea.

Multiple Units Control of Boiler and Refrigerator in HVAC System (공조용(空調用) 열원기기(熱源機器)의 대수분리(臺數分離) 제어(制御)에 관한 연구(硏究))

  • Sohn, J.Y.;Kim, H.S.;Ahn, B.W.;Shin, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • The purpose of this paper is to provide an efficient method of operating and designing HVAC systems for reasonable energy consumption in building. Accroding to the conditions of indoor temperature and humidity, and the methods of dividing and grouping the capacity of boiler and refrigerator, the amount of their annual energy consumptions is simulated by using an energy analysis program which is developed in this paper, and opatimal design methods of HVAC system are suggested as well.

  • PDF

Evaluation of combat calorie consumption based on GoBe2 nanosensor

  • Shuo Guan;Benxu Zou
    • Advances in nano research
    • /
    • v.14 no.6
    • /
    • pp.527-539
    • /
    • 2023
  • Measuring energy burn during intensive combat sport has been a challenging concerns for a long time. In the present article, the energy consumption during combat sports is measured by use of wearable GoBe2 equipped with nanotechnology measuring devices. In this regard, 12 professional combat athletes were asked to wear GoBe2 devices during different sessions of intensive combat exercises. The curves provided by GoBe2 nano-sensor devices are further collected and analyzed for different combat durations. On the other hand, energy consumption in these athlete is calculated using other validated methods to evaluate reliability of GoBe2 wearable devices. Based on the results obtained from these experiments a multi-parameter mathematical model is presented for estimation of combat calorie consumptions. The results show that nanotechnology in these type of sensors could help in estimation of calorie consumption during combat. Moreover, the reliability of using wearable GoBe2 sensors are satisfactory except for some specific conditions. The mathematical model provides a satisfactory results based on athlete physical condition and also duration of the combat with about 8% error margin in the results.