• 제목/요약/키워드: Energy consumption comparison

검색결과 445건 처리시간 0.03초

NAND 플래시 변환 계층에서 전력 소모에 영향을 미치는 페이지 캐싱 전략의 비교·분석 (A Comparative Analysis on Page Caching Strategies Affecting Energy Consumption in the NAND Flash Translation Layer)

  • 이형봉;정태윤
    • 대한임베디드공학회논문지
    • /
    • 제13권3호
    • /
    • pp.109-116
    • /
    • 2018
  • SSDs that are not allowed in-place update within the allocated page cause another allocation of a new page that will replace the previous page at the moment data modification occurs. This intrinsic characteristic of SSDs requires many changes to the existing HDD-based IO theory. In this paper, we conduct a performance comparison of FTL caching strategy in perspective of cache hashing (Global vs. grouped) and caching algorithm (LRU vs. NUR) through a simulation. Experimental results show that in terms of energy consumption for flash operation the grouped management of cache is not suitable and NUR algorithm is superior to LRU algorithm. In particular, we found that the cache hit ratio of LRU algorithm is about 10% point higher than that of NUR algorithm while the energy consumption of LRU algorithm is about 32% high.

대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석 (The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings)

  • 김병수;길영욱;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • 대형병원의 에너지 소비패턴을 분석한 후 마이크로가스터빈을 적용할 경우 기존 시스템 대비 냉난방에너지 절감량 및 전기에너지 절감량과 경제성분석을 통해 대형병원의 에너지 소비량을 절감하기 위한 에너지성능평가 모의연구를 수행하였다. 0.5[MW]급 마이크로 가스터빈을 설치한 후 에너지 성능분석을 한 결과 터빈에서의 발전효율은 30[%]이며, 전기는 건물에서 사용되는 조명에너지 뿐만 아니라 전체 전기에너지의 40[%]을 절감할 수 있는 것으로 분석되었다. 또한 터빈에서 발전되는 전기량과 배열을 냉난방에너지원으로 이용할 경우 전체 시스템효율은 70[%]로 상승할 뿐만 아니라 난방에너지의 56[%], 냉방에너지의 67[%]를 절감할 수 있는 것으로 분석되었으며 현가등가법에 의한 시스템 투자회수 기간이 약 9년으로 분석되었다.

인텔 펜티엄 4와 코어2 듀오의 실행시간과 파워소모량 효율성 비교 (The power consumption and performance comparison between Intel Pentium 4 and Core2 Duo)

  • 공준호;최진항;이종성;정성우
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권7호
    • /
    • pp.165-172
    • /
    • 2008
  • 프로세서의 설계 시 여러 가지 요소를 고려해야 하는데 특히 에너지, 파워 소모, 그리고 성능은 가장 기본적으로 고려해야 할 요소들이다. 이들 요소는 서로 상충되는 측면이 있기 때문에 프로세서의 설계 시에 설계 목적에 따라 어느 한 요소에 가중치를 주기도 한다. 본 논문에서는 펜티엄 4와 코어2 듀오의 정성적, 정량적 비교를 통해서 각 프로세서의 특성을 알아보고 실제 벤치마크를 실행시켰을 때 어떤 프로세서가 어떠한 측면에서 더 나은지 비교해보았다. 실제 프로세서의 성능 계수기를 통해서 파워, 에너지 소모를 fl산하였고 성능은 실행 시간으로 측정하였다. 결과로 코어2 듀오가 더 적은 에너지와 파워를 소모하는 것으로 나타났고, 성능 면에서도 펜티엄 4에 비해 나은 성능을 보여주었다. 그러나. 펜티엄 4에 최적화되어 컴파일 되어있던 bzip2의 경우 펜티엄 4가 에너지, 파워, 성능 면에서 코어2 듀오에 비해 월등하였다.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 - (Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF

건물 중앙냉방시스템의 에너지절감을 위한 최적운전 방안에 관한 실험적 연구 (Experimental Study on Optimal Operation Strategies for Energy Saving in Building Central Cooling System)

  • 황진원;안병천
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4610-4615
    • /
    • 2013
  • 본 연구에서는 중앙냉방시스템용 모형실험장치를 구성하여 에너지 소비량 및 전력사용요금의 절감을 위한 최적제어방법을 구현하여 실험적 연구를 수행하였다. 최적제어방법으로는 새벽시간의 예냉을 이용한 전력디맨드 응답제어와 외기온도변화를 고려한 외기보상제어방법 등을 고려하였으며, 제어알고리즘은 LabVIEW 프로그램을 이용하여 작성하였으며, 제어 및 모니터링을 통해 최적제어방법과 기존제어방법과의 제어성능을 비교 고찰하였다. 연구결과로서 본 연구에서 제시한 최적제어방법이 기존제어방법에 비해 양호한 응답특성을 나타냈으며, 에너지소비량은 약 9.5%, 전력요금은 약 15.7%를 각각 절감한 것으로 나타났다.

군간부 숙소에 적용된 중용량 및 멀티 보일러 시스템의 난방 및 급탕에너지 비교 (Heating and Hot Water Supply Energy Comparison of Medium Capacity and Multi Boilers System applied to Military Officer Housing)

  • 김민용;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Heating and hot water supply energy consumption of medium and multi boiler systems applied to military officer housing are compared with in-situ experiment and TRNSYS dynamic simulation program. In a multiple boiler system, small capacity boilers are connected in parallel to meet the required capacity. For handling partial loads, medium capacity boiler relies on on-off control, while multi boiler adopts PI control. Since multi boiler has higher efficiency and better control strategy, the results show that energy consumption can be reduced significantly with the multi boiler system.

팔걸이가 뇌졸중 환자의 보행속도 및 에너지 소모량에 미치는 영향 (Effect of Arm Sling on Walk Speed and Energy Consumption in Patients with Stroke)

  • 윤성익;김윤신;심재훈;오경아;오덕원;천승철
    • 대한물리치료과학회지
    • /
    • 제15권1호
    • /
    • pp.39-45
    • /
    • 2008
  • This study was undertaken to identify the influence which affect on gait speed and energy consumption regarding putting on arm sling during gait of the 40 hemiplegic patients selected from University Hospital and rehabilitation center in seoul during two months. The analysis of data was performed using the paired samples ttest to compare the differences of gait velocity, heart rate, oxygen consumption and oxygen cost in gait of preand post- arm sling. The results of this study were as follows; 1. When comparing the result before putting on arm sling in the gait of hemiplegic patient, gait velocity after putting on arm sling was statistically significantly increased(p<.05). 2. When comparing the result before putting on arm sling in the gait of hemiplegic patient, heart rate after putting on arm sling was statistically significantly decreased(p<.05). 3. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption per weight after putting on arm sling was statistically significantly decreased(p<.05). 4. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption rate per weight after putting on arm sling was statistically significantly decreased(p<.05). When putting together the above result, the gait with arm sling in comparison with the gait without arm sling was to increase gait velocity, decrease heart rate, decrease oxygen consumption and was finally to decrease energy consumption in the gait of hemiplegic patient.

  • PDF

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

원적외선 면상발열체에 의한 온실 난방시스템의 열특성 분석 (Thermal Energy Characteristics for Greenhouse Heating System with Far-Infrared Heater)

  • 노정근;김희준;리혁;한충수;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.529-534
    • /
    • 2006
  • The greenhouse heating system with far-infrared heater was built to analyze various thermal characteristics, such as greenhouse air temperature, soil temperature, energy flow, energy consumption in far-infrared heater, and other factors, which could be used in comparison with other greenhouse heating system in this study. The results showed that the inside air temperature of the far-infrared greenhouse heating system was $5^{\circ}C$ higher than that of hot air heating system. Heat loss of daytime was found to be larger than that of night time as much as 44.8% for the heating system with far-infrared heater. In the heating system with far-Infrared heater, when the lowest ambient temperature was -8 $\sim$ -7$^{\circ}C$, the air temperature of greenhouse was 12 $\sim$ 15$^{\circ}C$, thus the far-infrared heating system was shown to be feasible for heating system. Energy consumption of far-infrared heating system was shown to be less than that of hot air heating system.