교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 - (Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings -)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

설비관련제도 현황 - 건축물의 에너지절약 관련제도 중심으로 (The Present Status of Related Policies with Building Mechanical System - Centering around Policies for Energy Conservation of Buildings)

  • 오병칠
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1019-1025
    • /
    • 2006
  • There are so many related policies to design and construct building mechanical system. Therefore, preferentially in this study, purposes and major contents of related laws are summarized briefly. Subsequently, some points at issue and ways to improve laws and codes for energy conservation are suggested. From the results of this study, some points at issue are as follows : (1) Inconvenience in the application due to dispersion of similar codes. (2) Lack of systems and tools to verify and to evaluate the effect of energy conservation by any policy (3) Lack of the incentive Policy for Participator to conserve of energy.

  • PDF

국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발 (Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea)

  • 배민정;최경석
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

웹 기반의 공동주택 에너지 정보시스템 개발 및 시험평가 (A Development and Evaluation of an Web-based Apartment Buildings Energy Information System)

  • 김종엽;황하진;이종성
    • 토지주택연구
    • /
    • 제3권3호
    • /
    • pp.249-261
    • /
    • 2012
  • 건물운용단계의 에너지사용량은 우리나라 전체에너지 사용량의 약 25%이다. 지금까지 건물의 에너지사용량을 줄이기 위해서는 주로 설계단계에서 단열을 강화하고 고효율 기기를 사용해왔다. 이러한 노력들은 에너지절약 측면에서 그 한계가 있으며, 사용단계에서의 에너지절약생활이 큰 비중을 차지함에 따라 입주자들의 자발적인 참여로 인한 에너지절약 방법이 보다 효과적이라 할 수 있다. 이를 위해 본 연구에서는 에너지사용자에게 보다 적극적으로 에너지절약 프로그램에 동참시키기 위해 본인들이 사용한 에너지실적 정보를 웹상에서 서로 공유할 수 있는 프로그램을 개발하였다. 또한 프로그램의 필요성 및 사용의지를 조사하고 시범 적용하여 유효데이터의 수집가능성과 프로그램의 사용 용이성에 대하여 평가하였다.

노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가 (Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

Current Status of Passive Solar Building Applications in the Republic of Korea

  • Auh, Paul Chung-Moo
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.106-110
    • /
    • 1987
  • In the past few years, the subject of passive heating has been the major area of our concern due to the specific climate conditions prevailing in our region. More recently, however, other important issues such as retrofitting, passive cooling, optimized integration of conservation and passive solar, and daylighting have emerged as the areas of frequent discussions. KIER, the sole R&D organization in solar energy technologies, has accomplished significant results in passive building designs and actual demonstrations of experimental passive buildings. As a result of such endeavor by KIER, the passive solar buildings have been very well received by the Korean public. The current number of passive solar buildings in Korea is well over 1,600 (as of Dec. 1986). In this paper, broad aspects of the present status of passive solar technology utilization in Korea are presented.

  • PDF

초고층 건축물 시공단계를 위한 태양광시스템의 적용성 분석 (Applicability Analysis of Photovoltaic System in the Construction Phase of High-rise Buildings)

  • 강고운;김태훈;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2011
  • Recently, the development of alternative energy technologies has been actively conducted for energy conservation and CO2 emission reduction. Especially, photovoltaic energy has been applied practically in construction industry, and research on the building-integrated photovoltaic system (BIPV) that can replace fossil fuel for building operation and maintenance has been performed. However, this vibrant research has been limited to the use phase of buildings, and few studies have been carried out in the construction phase. The construction duration and the scale of the sites have increased along with the high-rise trend of buildings, and it is forecasted that the temporary electricity use and CO2 emission in the construction phase is increasing. In sight of these developments, this research analyzed applicability of the photovoltaic system for the construction phase that can replace the electricity used on the high-rise construction site.

  • PDF

건물성능개선을 위한 리모델링에 관한 연구 (A Study on Remodeling for Building Performance Improvement)

  • 김남효
    • 한국실내디자인학회논문집
    • /
    • 제25호
    • /
    • pp.42-48
    • /
    • 2000
  • The building remodeling is providing a lot of solutions - structural, aesthetic, environmental, and energy performance improvement - in improving buildings performance and environment. The remodelings influences on our society are resource conservation, environmental conservation, expansion of construction market, and creation of new employment. The three principal remodeler groups involved in this building remodeling are general construction contractors, interior architecture contractors, and ESCO (Energy Service Company). Having a representative character, this study classifies remodeling methods into five types: structural remodeling, spatial remodeling, exterior remodeling, environment-friendly remodeling, and ecological remodeling.

  • PDF

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권2호
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.

사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석 (The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling)

  • 최선우;김지연;박효순;김준태
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.