A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

Real-time Scheduling on Heterogeneous Multi-core Architecture for Energy Conservation of Smart Mobile Devices (스마트 모바일 장치의 에너지 보존성을 높이기 위한 비대칭 멀티 코어 기반 실시간 태스크 스케쥴링)

  • Lim, Sung-Hwa
    • Journal of Digital Contents Society
    • /
    • v.19 no.6
    • /
    • pp.1219-1224
    • /
    • 2018
  • Nowaday, smart mobile devices on Internet of Things are required to process and deliver greate amount of data in real-time. Therefore, heterogeneous mult-core architecture such the big.LITTLE core architecture, which shows high energy conservation while guaranteeing high performance, are widely employed on up to date smart mobile devices. The LITTLE cores should be highly utilized to gain higher energy conservation because LITTLE cores have much higher energy efficiency than big cores. In this paper, we propose a core selection algorithm, which tries to firstly assign a real-time task on a LITTLE core rather a big core while the task can be finished within its own deadline. We also perform simulation as performance evaluation to show that our proposed algorithm shows higher energy conservation while guaranteeing the required performance.

Gene Analysis Related Energy Metabolism of Leaf Expressed Sequence Tags Database of Korean Ginseng (Panax ginseng C.A. Meyer) (고려인삼(Panax ginseng C.A, Meyer)의 잎 ESTs database에서 Energy 대사 관련 유전자 분석)

  • Lee Jong-Il;Yoon Jae-Ho;Song Won-Seob;Lee Bum-Soo;In Jun-Gyo;Kim Eun-Jeong;Yang Deok-Chun
    • Korean Journal of Plant Resources
    • /
    • v.19 no.1
    • /
    • pp.174-179
    • /
    • 2006
  • A cDNA library was constructed from leaf samples of 4-year-old Panax ginseng cultured in a field. 3,000 EST from a size selected leaf cDNA library were analyzed. The 349 of 2,896 cDNA clones has related with energy metabolism genes. The 349 known genes were categorized into nine groups according to their functional classification, aerobic respiration(48.4%), accessory proteins of electron transport and membrane associated energy conservation(17.2%), glycolysis and gluconeogenesis(3.4%), electron transport and membrane associated energy conservation(2.9%), respiration(2.0%), glycolysis methylglyoxal bypass(1.7%), metabolism of energy reserves(0.6%) and alcohol fermentation(0.3%).

A Study on Establishment of the Basic Plan to Construct an Integrated Management System of National Building Energy (건물 부문의 에너지 관리체계 구축수립 기본 방안에 관한 연구)

  • Yoo, Jung-Hyun;Kim, Jong-Yeob;Hwang, Ha-Jin
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.379-385
    • /
    • 2011
  • Energy consumption of building is given a sizable portion in total national energy conservation and if current trends continues, energy conservation level will rise as level of developed country. For this reason, a basic plan is proposed for integrated management system to manage energy conservation of buildings using a link with energy information and building information. Specifically, the questionnaire investigation conducted by building energy expert is performed to determine the projects along with time schedule and demands level of management system. In addition, to investigate study on energy usage information and management situation the management architecture of energy supplier is also studied.

Distance Aware Intelligent Clustering Protocol for Wireless Sensor Networks

  • Gautam, Navin;Pyun, Jae-Young
    • Journal of Communications and Networks
    • /
    • v.12 no.2
    • /
    • pp.122-129
    • /
    • 2010
  • Energy conservation is one of the most important issues for evaluating the performance of wireless sensor network (WSN) applications. Generally speaking, hierarchical clustering protocols such as LEACH, LEACH-C, EEEAC, and BCDCP are more efficient in energy conservation than flat routing protocols. However, these typical protocols still have drawbacks of unequal and high energy depletion in cluster heads (CHs) due to the different transmission distance from each CH to the base station (BS). In order to minimize the energy consumption and increase the network lifetime, we propose a new hierarchical routing protocol, distance aware intelligent clustering protocol (DAIC), with the key concept of dividing the network into tiers and selecting the high energy CHs at the nearest distance from the BS. We have observed that a considerable amount of energy can be conserved by selecting CHs at the nearest distance from the BS. Also, the number of CHs is computed dynamically to avoid the selection of unnecessarily large number of CHs in the network. Our simulation results showed that the proposed DAIC outperforms LEACH and LEACH-C by 63.28% and 36.27% in energy conservation respectively. The distance aware CH selection method adopted in the proposed DAIC protocol can also be adapted to other hierarchical clustering protocols for the higher energy efficiency.

Selective Production of Aromatic Aldehydes from Heavy Fraction of Bio-oil via Catalytic Oxidation

  • Li, Yan;Chang, Jie;Ouyang, Yong;Zheng, Xianwei
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.1654-1658
    • /
    • 2014
  • High value-added aromatic aldehydes (e.g. vanillin and syringaldehyde) were produced from heavy fraction of bio-oil (HFBO) via catalytic oxidation. The concept is based on the use of metalloporphyin as catalyst and hydrogen peroxide ($H_2O_2$) as oxidant under alkaline condition. The biomimetic catalyst cobalt(II)-sulfonated tetraphenylporphyrin ($Co(TPPS_4)$) was prepared and characterized. It exhibited relative high activity in the catalytic oxidation of HFBO. 4.57 wt % vanillin and 1.58 wt % syringaldehyde were obtained from catalytic oxidation of HFBO, compared to 2.6 wt % vanillin and 0.86 wt % syringaldehyde without $Co(TPPS_4)$. Moreover, a possible mechanism of HFBO oxidation using $Co(TPPS_4)/H_2O_2$ was proposed by the research of model compounds. The results showed that this is a promising and environmentally friendly method for production of aromatic aldehydes from HFBO under $Co(TPPS_4)/H_2O_2$ system.

Real-Time Building Load Prediction by the On-Line Weighted Recursive Least Square Method (실시간 가중 회기최소자승법을 사용한 익일 부하예측)

  • 한도영;이재무
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.609-615
    • /
    • 2000
  • The energy conservation is one of the most important issues in recent years. Especially, the energy conservation through improved control strategies is one of the most highly possible area to be implemented in the near future. The energy conservation of the ice storage system can be accomplished through the improved control strategies. A real time building load prediction algorithm was developed. The expected highest and the lowest outdoor temperature of the next day were used to estimate the next day outdoor temperature profile. The measured dry bulb temperature and the measured building load were used to estimate system parameters by using the on-line weighted recursive least square method. The estimated hourly outdoor temperatures and the estimated hourly system parameters were used to predict the next day hourly building loads. In order to see the effectiveness of the building load prediction algorithm, two different types of building models were selected and analysed. The simulation results show less than 1% in error for the prediction of the next day building loads. Therefore, this algorithm may successfully be used for the development of improved control algorithms of the ice storage system.

  • PDF

A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools (실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구)

  • 김영돈;권규동;여명석;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).

On the equivalence of reaction rate in energy collapsing of fast reactor code SARAX

  • Xiao, Bowen;Wei, Linfang;Zheng, Youqi;Zhang, Bin;Wu, Hongchun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.732-740
    • /
    • 2021
  • Scattering resonance of medium mass nuclides leads complex spectrum in the fast reactor, which requires thousands of energy groups in the spectrum calculation. When the broad-group cross sections are collapsed, reaction rate cannot be completely conserved. To eliminate the error from energy collapsing, the Super-homogenization method in energy collapsing (ESPH) was employed in the fast reactor code SARAX. An ESPH factor was derived based on the ESPH-corrected SN transport equation. By applying the factor in problems with reflective boundary condition, both the effective multiplication factor and reaction rate were conserved. The fixed-source iteration was used to ensure the stability of ESPH iteration. However, in the energy collapsing process of SARAX, the vacuum boundary condition was adopted, which was necessary for fast reactors with strong heterogeneity. To further reduce the error caused by leakage, an additional conservation factor was proposed to correct the neutron current in energy collapsing. To evaluate the performance of ESPH with conservation factor, numerical benchmarks of fast reactors were calculated. The results of broad-group calculation agreed well with the direct full-core Monte-Carlo calculation, including the effective multiplication factor, radial power distribution, total control rod worth and sodium void worth.

FINITE ELEMENT SCHEME FOR THE VISCOUS CAHN-HILLIARD EQUATION WITH A NONCONSTANT GRADIENT ENERGY COEFFICIENT

  • CHOO S. M.;KIM Y. H.
    • Journal of applied mathematics & informatics
    • /
    • v.19 no.1_2
    • /
    • pp.385-395
    • /
    • 2005
  • A finite element scheme is considered for the viscous Cahn-Hilliard equation with the nonconstant gradient energy coefficient. The scheme inherits energy decay property and mass conservation as for the classical solution. We obtain the corresponding error estimate using the extended Lax-Richtmyer equivalence theorem.