ZVT boost converter with minimizing conduction losses of the main switch (주 스위치의 전도손실을 최소화한 ZVT 부스터 컨버터)

  • Chin Gi-Ho;Kang Ahn-Jong;Kim Tae-Woo;Kim Hack-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.95-98
    • /
    • 2003
  • A ZVT PWM Boost Converter is proposed to reduce current stresses and conduction losses of main switch in a conventional circuit. By attaching resonant inductor Lr1 in parallel with capacitor Cr, the resonant circulating current is diverted to the additional component and then the main switch is subjected to minimum current stresses same as those in their PWM counterparts. Moreover, the operation of the auxiliary switch in a half wave mode to prevent reverse resonant energy from freewheeling can be able to lessen the conduction losses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed circuit.

  • PDF

Thermohydrodynamic Bubbly Lubrication Analysis of High-Speed Journal Bearing (공기 혼합오일에 대한 고속 저어널 베어링 열유체 윤활 해석)

  • 전상명
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.201-211
    • /
    • 2001
  • The influence of aerated oil on high-speed journal bearing is examined by classical thermohydrodynamic lubrication theory coupled with analytical models for viscosity and density of aerated oil in fluid-film bearing. Convection to the walls, mixing with supply oil and re-circulating oil, and some degree of journal misalignment are considered. The considered Parameters for the study of bubbly lubrication are oil aeration level, air bubble size, shaft misalignment and shaft speed. The results show that deliberate oil aeration can more clearly bring on the increasing load capacity under high-speed operation of plain journal hearing than previous normal speed operation. And the load capacity may be increased more by oil aeration under the conditions of shaft misalignment and the increasing speed.

  • PDF

Solid Circulation Characteristics of Oxygen Carrier for Chemical Looping Combustion System at Ambient Temperature and Pressure (케미컬루핑 연소시스템을 위한 산소전달입자의 상온-상압 고체순환특성)

  • YOON, JOOYOUNG;KIM, HANA;KIM, JUNGHWAN;LEE, DOYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.384-391
    • /
    • 2017
  • Effects of operating variables on solid circulation rate were measured and discussed using two-interconnected circulating fluidized bed system at ambient temperature and pressure. OCN 706-1100 particles were used as oxygen carrier. The measured solid circulation rates increased as the lower loop seal gas flow rates and the solid height in the fuel reactor increased. Suitable operating conditions to avoid choking of the air reactor were confirmed. Continuous long-term operations of steady-state solid circulation were also demonstrated at two different conditions based on the operating window.

Analysis of Oxygen Combustion Characteristics of a Low Grade Coal Using IEA-CFBC Model (IEA-CFBC 모델을 이용한 저급탄의 순산소 연소 특성 분석)

  • Gwak, You Ra;Kim, Ye Bin;Keel, Sang In;Yun, Jin Han;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.56 no.5
    • /
    • pp.631-640
    • /
    • 2018
  • The application of an oxy-combustion circulating fluidized bed combustor (Oxy-CFBC) for low grade coals has recently developed in the world to meet the continuous increase of energy demand and to achieve the reduction of greenhouse gases. Since demo plants for Oxy-CFBC have been developed, the combustion properties of Oxy-CFBC in various operation conditions, such as gas flow rates, combustion temperature, fuel, and so on, should be investigated to develop design criteria for a commercial Oxy-CFBC. In this study, a computational simulation tool for Oxy-CFBC was developed on the basis of the IEA-CFBC (International Energy Agency Circulating Fluidized Bed Combustor) model. Simulation was performed under various conditions such as reaction temperature ($800^{\circ}C{\sim}900^{\circ}C$), oxygen contents (21%~41%), coal feeding rate, Ca/S mole ratio (1.5~4.0), and so on. Simulation results show that the combustion furnace temperature is higher in oxy 1 than air fired. However, the temperature gradient tended to decrease with increasing oxy mixing percent. In case of $SO_x$, the higher the Ca/S mole ratio and oxy mixing percent, the higher the desulfurization efficiency.

Voltage-Fed Push-Pull PWM Converter Featuring Wide ZVS Range and Low Circulating Loss with Simple Auxiliary Circuit

  • Ye, Manyuan;Song, Pinggang;Li, Song;Xiao, Yunhuang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.965-974
    • /
    • 2018
  • A new zero-voltage-switching (ZVS) push-pull pulse-width modulation (PWM) converter is proposed in this paper. The wide ZVS condition for all of the switches is obtained by utilizing the energy stored in the output inductor and magnetizing inductance. As a result, the switching losses can be dramatically reduced. A simple auxiliary circuit including two small diodes and one capacitor is added at the secondary side of a high frequency (HF) transformer to reset the primary current during the circulating stage and to clamp the voltage spike across the rectifier diodes, which enables the use of low-voltage and low-cost diodes to reduce the conducting and reverse recovery losses. In addition, there are no active devices or resistors in the auxiliary circuit, which can be realized easily. A detailed steady operation analysis, characteristics, design considerations, experimental results and a loss breakdown are presented for the proposed converter. A 500 W prototype has been constructed to verify the effectiveness of the proposed concept.

A New DC-DC Full-Bridge Converter with Using Regenerative Transformer (회생변압기를 이용한 새로운 전력회수형 풀브리지 컨버터)

  • Kim, J.H.;Hyun, B.C.;Lee, J.M.;Cho, B.H.;Lee, D.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.395-398
    • /
    • 2005
  • A novel full-bridge converter with a new energy-recovery driver implemented a regenerative transformer is proposed to improve the efficiency for wide input voltage range and load variation. The main switches achieve ZVS independent of the load current condition. During the free wheeling period, conduction loss is minimized by recovering the circulating energy to the source. The principle of operation, design consideration and experimental result, including efficiency, are presented in the case of large variation of the input voltage or load. A proposed 1kW converter prototype is compared with a PS-FB converter.

  • PDF

Solid Circulation Characteristics of Two Oxygen Carriers for Chemical Looping Combustion System (케미컬루핑 연소시스템을 위한 두 가지 산소전달입자들의 고체순환 특성)

  • RYU, HO-JUNG;LEE, DOYEON;NAM, HYUNGSEOK;JO, SUNG-HO;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.393-400
    • /
    • 2018
  • To confirm the operating range of two oxygen carriers for chemical looping combustion system, the effects of operating variables on solid circulation rate were measured and discussed using a two-interconnected circulating fluidized bed system at ambient temperature and pressure. Moreover, suitable operating ranges to avoid choking of the fast fluidized bed (air reactor) were confirmed for two oxygen carriers. A continuous long-term operation of steady-state solid circulation more than 24 hours was also demonstrated within the operating windows. Finally we could confirm that those two oxygen carriers are suitable for chemical looping combustion system with high solid circulation rate and smooth solid circulation.

Autonomous Operation Analysis of DC Microgrid based on Droop Control (Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석)

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.342-350
    • /
    • 2011
  • This paper describes the autonomous operation analysis of DC microgrid based on droop control. In order to verify the whole system operation, detailed simulation models for wind power generation, solar power generation, and battery were developed with user-defined models programmed with C-code in PSCAD/ EMTDC software. The simulation results confirm that the DC microgrid with droop control make it feasible to provide power to the load with stable manner. Based on simulation results a prototype of DC microgrid was built and tested in the lab to verify the autonomous operation experimentally. The droop control scheme can suppress the circulating current, and offers each unit to be controlled autonomously without any communication link.

The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구)

  • Lee, Dong-Won;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

Desulfurization Characteristics of Domestic Limestones through Simultaneous Calcination and Desulfurization Reaction (국내 석회석들의 소성 탈황 동시반응 특성)

  • Shin, Ji Hoon;Kim, Yea Ra;Kook, Jin Woo;Kwak, In Seop;Park, Kyoung-Il;Lee, Jong-Min;Lee, See Hoon
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.557-562
    • /
    • 2015
  • In order to analyze and compare the desulfurization characteristics of five different kinds of domestic limestons, a thermogravimetric analyzer (TGA) was used in this study. Calcium carbonate contents of the domestic limestone varied from 91 to 96 wt%. Experimental temperature and sulfur dioxide concentration of $850^{\circ}C$ and 2,750 ppm, respectively were selected to simulate commercial operation conditions. In this study, the calcination and desulfurization reaction of limestones were simultaneously occurred and investigated to simulate in-situ desulfurization reaction in commercial circulating fluidized bed combustors. In addition, desulfurization reactivities of limes having the average particle sizes of 37.5, 90.5, 159, 356 and $750{\mu}m$ were investigated. Desulfurization reactivities via simultaneous calcination and desulfurization reactions were 5-20% lower than those of using general desulfurization reactions.