• Title/Summary/Keyword: Energy change ratio

Search Result 720, Processing Time 0.027 seconds

Permeability Effect of Decomposed Granite Soil under the Influence of Crushability and Compaction Energy (화강풍화토(花崗風化土)의 파쇄(破碎) 및 다짐에너지가 투수성(透水性)에 미치는 영향(影響))

  • Lee, Hyoung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.107-116
    • /
    • 1983
  • This paper is concerned with the permeability through a decomposed granite soil layer which is influnced by change of grain sizes and crushed soils made by varied compaction energy. The change in the content of crushed soils can be described in terms of the ratio of surface area ($S_w{^{\prime}}/S_w $). The experiments were carried out to obtain the relationships of the coefficient of permeability(K) versus the optimum moisture content($w_{opt}$) by the variable head permeability test with the samples that were preapared by compaction test. The results are found as follows; (1) By the change in compaction energy, the crush ratio increased whereas the void ratio decreased with a larger maximum dry density running in parallel with the zero air void curve. (2) The ratio of surface area was $0.33(P)^{0.96}$ in $S_w{^{\prime}}/S_w $ with no relation to the compaction energy. (3) The grain size which produced the largest crush of soil particles ranged from 0.5 to 1 millimetre (4) The relationship of K versus $e^3$/1+e appeared as a straight line on the full-log-scale paper under the optimum moisture state. (5) As the compaction energy was larger, the passing percentage of #200-sieve grains increased linearly. The increment in the surface area ratio was deemed to have been caused by the decreased in the permeability.

  • PDF

The change of vowel characteristics for the dysarthric speech along with speaking style (경도 마비말장애 환자의 발화 유형에 따른 모음 특성 비교)

  • Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.8 no.3
    • /
    • pp.51-59
    • /
    • 2016
  • The purpose of present study is to examine differences between habitual speech (HS) and clear speech (CS) in individuals with mild dysarthria. Twelve speakers with mild dysarthria and twelve healthy control speakers read sentences in two speaking styles. Formant and intensity related values, triangular area, and center of gravity of /a/, /i/, and /u/ were measured. In addition, formant-ratio variables such as vowel space area(VSA), vowel articulatory index (VAI), formant centralization ratio (FCR) and F2i/F1u ratio (F2 ratio) were calculated. The results of repeated-measures ANOVA showed a significant difference in F2 of vowel /i/ and F2 energy of vowel /a/ between groups. Regarding formant energy, F2 energy of vowel /a/ were observed as meaningful variables between speaking styles. There were significant speaking style-by-group interactions for F2 energy of vowel /a/. These findings indicated that current parameters could discriminate healthy group and mild dysarthria group meaningfully and that speaker with dysarthria had larger clear speech benefit than healthy talkers. We also claim that various acoustic changes of clear speech may contribute to improving vowel intelligibility.

The Characteristics of Coal Gasification using Microwave Plasma (마이크로웨이브 플라즈마를 이용한 석탄가스화 특성 연구)

  • Kim, Doo-Il;Lee, Jae-Goo;Kim, Yong-Ku;Yoon, Sang-Jun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.93-99
    • /
    • 2012
  • The investigation of clean and environment-friendly coal utilization technology is actively progressed due to high oil price and serious climate change caused by greenhouse gas emissions. In this study, the plasma gasification was performed using a 6kW microwave plasma unit under various reaction conditions: the particle sizes of coal ($45{\mu}m-150{\mu}m$), $O_2$/fuel ratio (0 - 1.3), and steam/fuel ratio (0 - 1.5). The $H_2$ composition decreases with decreasing coal particle size. With increasing $O_2$/fuel ratio, the $H_2$ composition in the syngas decreased while the $CO_2$ composition increased. As the steam/fuel ratio increased from 0 to 1.5, the $H_2$ composition in the syngas increased while the $CO_2$ composition decreased. From the results, it was proven that the variation of syngas composition greatly affected by $O_2$/fuel ratio than steam/fuel ratio. The $H_2$ composition in the syngas, carbon conversion, and cold gas efficiency increased with increasing plasma power.

Experimental Study on the Engineering Characteristics of Weathering Mudstone -In Pohang area- (이암 황화토의 공학적 특성에 관한 실험적 연구 -포항지역의 이암봉화토를 중심으로-)

  • 김영수;박강우
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.5-16
    • /
    • 1994
  • This paper is concerned with the engineering characteristics weathered mudstone soil in Pohang area. The crushability of weathered Boil can be described in terms of the ratio of surface area(Sw'/Sw). In this study, the characteristics of weathered mudstone soil was investigated by performing teat such as compaction. CBR, permeability, and grain size according to compaction energy. The results are found as follows : (1) In generally, the specific gravity of weathered mudstone soil is very small and optimum moisture content (OMC) is large and maximum dry density is small (2) The CBR value increases as the compaction energy increases, but this value decreses from D -2 compaction(26kg.cm/cm3). the swelling ratio increases the npaction energy to 20.6kg.cm/cm" and decreases in all compaction energy from 20.6kg.cm/cm3 (3) As the compaction energy is small, the change of permeability due to water content is large and the difference between minimum coefficient of permeability and coefficient of permeability at OMC is large, but the difference is small as the compaction energy increases (4) The decrease of permeability due to the decrease of void ratio and the increase of ratio of surface area is caused by the crush of particle due to the increase in compaction energy. Especially, the compaction energy is smaller, the change of the ratio of surface area to the coefficient of permeability is larger.rger.

  • PDF

A Fundamental Study On the Self-Sufficient Heating Energy for Residential Building (주거용 건물의 난방 에너지 자립을 위한 기초 연구)

  • Son, Sun-Woo;Baek, Nam-Choon;Suh, Seung-Jik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.255-258
    • /
    • 2009
  • Leading developed countries have studied energy self-sufficient houses such as zero or low energy buildings to reduce energy consumption for buildings since the early 1990s. Moreover, some developed countries have actually constructed self-sufficient houses and operated them for demonstration, expanding use of such houses. Korea has also established Zero Energy Solar House(ZeSH) and studied energy independence. Therefore, this study analyzed research result regarding ZeSH, self-sufficient energy house hold of Korea, found out technologies used for heating energy independence, used building interpretation program(ESP_r) to evaluate performance of each factors and analyzed energy reduction quantitatively. Results from the research are as follows: Reduction rate of actual detached house's heating load was also analyzed quantitatively depending on application of each technology. When each factor was applied step-by-step, annual reduction rate of heating load depending on increase in insulation thickness reached 6.6~22.2 %. Annual reduction rate of heating load depending on increase insulation thickness, and change in window heating performance and area ratio reached 31.5 %. Annual reduction rate of heating load through high-sealing and high-insulation depending on change in leakage rate reached 40.0~88.9 %. Annual reduction of heating load, when Mass Wall and attached sun space was applied were applied reached 28.5~39.2 %, respectively.

  • PDF

A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy (냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

Fault Detections of Ring Structures using Vibration Modes (진동모드를 이용한 링 구조물의 결함 탐지)

  • Kim, Seock-Hyun;Jang, Ho-Sik
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.29-36
    • /
    • 2002
  • A damage detection algorithm using vibration modes is applied to the ring structures and the modal behaviors of the slightly asymmetric rings are examined. Mode shape change, MSER(modal strain energy ratio) and MCR(modal curvature ratio) are investigated to identify the locations of faults or damages The above fault detection parameters are calculated and compared by the finite element analysis on rings with designed local damages. Damages are modeled as a reduced stiffness in the analysis The results show that MSER and MCR can be proper parameters to detect local damages in the ring structures.

  • PDF

A Study on Expansion of Back Fire Limit Equivalence Ratio of the Hydrogen Fueled Engine (수소기관의 역화한계당량비 확장에 관한 연구)

  • Paik, Sung Ho;Park, Jae Bum;Kim, Yun Young;Lee, Jong Tae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.8 no.3
    • /
    • pp.111-119
    • /
    • 1997
  • In this study, feasibility of expansion of BFL equivalence ratio are examined with change of injection location of hydrogen gas in intake pipe, coolant temperature, spark timing and amount of residual gas. As the results, BFL equivalence ratio is increased when injection location has some distance from intake valve. And it is decreased in accordance with increasing of coolant temperature and advance of spark timing. The amount of residual gas has little effect on BFL equivalence ratio.

  • PDF

Estimating the Loss Ratio of Solar Photovoltaic Electricity Generation through Stochastic Analysis

  • Hong, Taehoon;Koo, Choongwan;Lee, Minhyun
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.3
    • /
    • pp.23-34
    • /
    • 2013
  • As climate change and environmental pollution become one of the biggest global issues today, new renewable energy, especially solar photovoltaic (PV) system, is getting great attention as a sustainable energy source. However, initial investment cost of PV system is considerable, and thus, it is crucial to predict electricity generation accurately before installation of the system. This study analyzes the loss ratio of solar photovoltaic electricity generation from the actual PV system monitoring data to predict electricity generation more accurately in advance. This study is carried out with the following five steps: (i) Data collection of actual electricity generation from PV system and the related information; (ii) Calculation of simulation-based electricity generation; (iii) Comparative analysis between actual electricity generation and simulation-based electricity generation based on the seasonality; (iv) Stochastic approach by defining probability distribution of loss ratio between actual electricity generation and simulation-based electricity generation ; and (v) Case study by conducting Monte-Carlo Simulation (MCS) based on the probability distribution function of loss ratio. The results of this study could be used (i) to estimate electricity generation from PV system more accurately before installation of the system, (ii) to establish the optimal maintenance strategy for the different application fields and the different season, and (iii) to conduct feasibility study on investment at the level of life cycle.

Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module (스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구)

  • Yoon, Jong-Ho;Kim, Dong-Su;Oh, Myung-Hwan;Lee, Jae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.