수소기관의 역화한계당량비 확장에 관한 연구

A Study on Expansion of Back Fire Limit Equivalence Ratio of the Hydrogen Fueled Engine

  • 백성호 (성균관대학교 기계공학과) ;
  • 박재범 (성균관대학교 기계공학과) ;
  • 김윤영 (성균관대학교 기계공학과) ;
  • 이종태 (성균관대학교 기계공학과)
  • Paik, Sung Ho (Department of Mechanical Engineering, SungKyunKwan University) ;
  • Park, Jae Bum (Department of Mechanical Engineering, SungKyunKwan University) ;
  • Kim, Yun Young (Department of Mechanical Engineering, SungKyunKwan University) ;
  • Lee, Jong Tae (Department of Mechanical Engineering, SungKyunKwan University)
  • 발행 : 1997.09.15

초록

In this study, feasibility of expansion of BFL equivalence ratio are examined with change of injection location of hydrogen gas in intake pipe, coolant temperature, spark timing and amount of residual gas. As the results, BFL equivalence ratio is increased when injection location has some distance from intake valve. And it is decreased in accordance with increasing of coolant temperature and advance of spark timing. The amount of residual gas has little effect on BFL equivalence ratio.

키워드