• 제목/요약/키워드: Energy and mass exchange

검색결과 98건 처리시간 0.03초

Counter anion effects in anion exchange membrane-fabricated non-aqueous vanadium redox flow battery

  • Son, Pyeong Soo;Oh, Min-Seok;Ye, Jun-Hee;Choi, Seong-Ho
    • 분석과학
    • /
    • 제28권5호
    • /
    • pp.341-346
    • /
    • 2015
  • In order to understand the counter anionic effects in a non-aqueous vanadium redox flow battery (VRFB), we synthesized four types of electrolyte salts (1-ethyltriethamine tertafluoroborate, [E-TEDA]+[BF4], 1-ethyltriethamine hexafluorophosphate, [E-TEDA]+[PF6], 1-butyltriethylamine tertafluoroborate, [B-TEDA]+[BF4], and 1-buthyltriethamine hexafluorophosphate [B-TEDA]+[PF6]) by counter anion exchange reaction after the SN2 reaction. We confirmed the successful synthesis of the electrolyte salts [E-TEDA]+[Br] and [B-TEDA]+[Br] via 1H-NMR spectroscopy and GC-mass analysis before the counter anion exchange reaction. The electric potential of the vanadium acetylacetonate, V(acac)3, as an energy storage chemical was shown to be 2.2 V in the acetonitrile solvent with each of the [E-TEDA]+[BF4], [E-TEDA]+[PF6], [B-TEDA]+[BF4], and [B-TEDA]+[PF6] electrolyte salts. In a non-aqueous VRFB with a commercial Neosepta AFN membrane, the maximum voltages reached 1.0 V and 1.5 V under a fixed current value of 0.1 mA in acetonitrile with the [E-TEDA]+[BF4] and [E-TEDA]+[PF6] electrolyte salts, respectively. The maximum voltage was 0.8 V and 1.1 V under a fixed current value of 0.1 mA in acetonitrile with the [B-TEDA]+[BF4] and [B-TEDA]+[PF6] electrolyte salts, respectively. From these results, we concluded that in the non-aqueous VRFB more of the [PF6] counter anion than the [BF4] counter anion was transported onto the commercial Neosepta AFN anion exchange membrane.

고분자전해질 연료전지의 성능에 미치는 습도와 플러딩의 영향 (Effect of Humidity and Flooding on the Performance of Proton Exchange Membrane Fuel Cell)

  • 황병찬;정회범;송명현;오성준;나일채;박권필
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.302-306
    • /
    • 2017
  • 고분자전해질 연료전지에서 습도는 성능과 내구성에 많은 영향을 준다. 습도가 높아지면 일반적으로 성능이 향상되는데 높은 습도는 플러딩을 발생시킬 위험성도 있다. 미세 유로셀에서 상대습도를 변화시키며 I-V곡선, LSV, 사이클로 볼타메트리(CV), 임피던스을 측정했다. 70%이상에서 플러딩 현상이 발생함을 확인했다. 고분자막의 이온전도도는 상대습도 80%에서 최고값에 도달했고, 전극의 활성은 플러딩 후에도 상대습도 증가에 따라 상승했다. 상대습도 80%에서 최고 성능 $1,700mA/cm^2$(@0.6 V)을 얻었다. 상대습도 80%에서 플러딩에 의해 물질전달이 방해 받는 것에 비해 막의 이온전도도 향상이 성능에 더 큰 영향을 줌을 보였다.

Cathode에 따른 휴대용 PEM 연료전지의 성능 변화 (Performance of the PEMFC for the mobile devices according to cathode)

  • 이세원;이강인;박민수;주종남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.550-553
    • /
    • 2008
  • In this paper, experiments of air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to the cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single cell and 6-cell stack were used in this experiments. The experimental results showed that the open type cathode flow field plate gave better performance for small size PEMFCs because the open type cathode plate allowed better air convection than the channel type cathode plate. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical slit cell. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, PEMFC generated more stable power in the mass transport loss region.

  • PDF

Feasible approach of contactless power transfer technology combined with HTS coils based on electromagnetic resonance coupling

  • Chung, Yoon Do;Yim, Seong Woo;Hwang, Si Dole
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.40-44
    • /
    • 2013
  • The contactless power transfer (CPT) systems have been recently gaining popularity widely since it is an available option to realize the power delivery and storage with connector-free devices across a large air gap. Especially, the CPT with electromagnetic resonance coupling method is possible to exchange energy within 2 m efficiently. However, the power transfer efficiency of CPT in commercialized products has been limited because the impedance matching of coupled coils is sensitive. As a reasonable approach, we combined the CPT system with HTS wire technology and called as, superconducting contactless power transfer (SUCPT) system. Since the superconducting coils have an enough current density, the superconducting antenna and receiver coils at CPT system have a merit to deliver and receive a mass amount of electric energy. In this paper, we present the feasibility of the SUCPT system and examine the transmission properties of SUCPT phenomenon between room temperature and very low temperature at 77 K as long as the receiver is within 1.0 m distance.

Application of brass scrubber filter with copper hydroxide nanocomposite structure for phosphate removal

  • Hong, Ki-Ho;Yoo, In-Sang;Kim, Sae-Hoon;Chang, Duk;Sunwoo, Young;Kim, Dae-Gun
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.199-204
    • /
    • 2015
  • In this study, a novel phosphorus removal filter made of brass scrubber with higher porosity of over 96% was fabricated and evaluated. The brass scrubber was surface-modified to form copper hydroxide on the surface of the brass, which could be a phosphate removal filter for advanced wastewater treatment because the phosphates could be removed by the ion exchange with hydroxyl ions of copper hydroxide. The evaluation of phosphate removal was performed under the conditions of the batch type in wastewater and continuous type through filters. Filter recycling was also evaluated with retreatment of the surface modification process. The phosphate was rapidly removed within a very shorter contact time by the surface-modified brass scrubber filter, and the phosphate mass of 1.57 mg was removed per gram of the filter. The possibility of this surface-modified brass scrubber filter for phosphorus removal was shown without undesirable sludge production of existing chemical phosphorus removal techniques, and we feel that it would be very meaningful as a new wastewater treatment.

수동급기 직접 메탄올 연료전지의 동적 모델 (Dynamic Model of a Passive Air-Breathing Direct Methanol Fuel Cell)

  • 하승범;장익황;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • The transient behavior of a passive air breathing direct methanol fuel cell (DMFC) operated on vapor-feeding mode is studied in this paper. It generally takes 30 minutes after starting for the cell response to come to its steady-state and the response is sometimes unstable. A mathematical dynamic one-dimensional model for simulating transient response of the DMFC is presented. In this model a DMFC is decomposed into its subsystems using lumped model and divided into five layers, namely the anodic diffusion layer, the anodic catalyst layer, the proton exchange membrane (PEM), the cathodic catalyst layer and the cathodic diffusion layer. All layers are considered to have finite thickness, and within every one of them a set of differential-algebraic governing equations are given to represent multi-components mass balance, such as methanol, water, oxygen and carbon dioxide, charge balance, the electrochemical reaction and mass transport phenomena. A one-dimensional, isothermal and mass transport model is developed that captures the coupling between water generation and transport, oxygen consumption and natural convection. The single cell is supplied by pure methanol vapor from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The water is not supplied from external source because the cell uses the water created at the cathode using water back diffusion through nafion membrane. As a result of simulation strong effects of water transport were found out. The model analysis provides several conclusions. The performance drop after peak point is caused by insufficiency of water at the anode. The excess water at the cathode makes performance recovery impossible. The undesired crossover of the reactant methanol through the PEM causes overpotential at the cathode and limits the feeding methanol concentration.

  • PDF

Recent advances in the characterization and the treatment methods of effluent organic matter

  • Ray, Schindra Kumar;Truong, Hai Bang;Arshad, Zeshan;Shin, Hyun Sang;Hur, Jin
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.257-274
    • /
    • 2020
  • There are many previous review articles are available to summarize either the characterization methods of effluent organic matter (EfOM) or the individual control treatment options. However, there has been no attempt made to compare in parallel the physicochemical treatment options that target the removal of EfOM from biological treatments. This review deals with the recent progress on the characterization of EfOM and the novel technologies developed for EfOM treatment. Based on the publications after 2010, the advantages and the limitations of several popularly used analytical tools are discussed for EfOM characterization, which include UV-visible and fluorescence spectroscopy, Fourier transform infrared spectroscopy (FTIR), size exclusion chromatography (SEC), and Fourier transform-ion cyclotron resonance-mass spectrometry (FT-ICR-MS). It is a recent trend to combine an SEC system with various types of detectors, because it can successfully track the chemical/functional composition of EfOM, which varies across a continuum of different molecular sizes. FT-ICR-MS is the most powerful tool to detect EfOM at molecular levels. However, it is noted that this method has rarely been utilized to understand the changes of EfOM in pre-treatment or post-treatment systems. Although membrane filtration is still the preferred method to treat EfOM before its discharge due to its high separation selectivity, the minimum requirements for additional chemicals, the ease of scaling up, and the continuous operation, recent advances in ion exchange and advanced oxidation processes are greatly noteworthy. Recent progress in the non-membrane technologies, which are based on novel materials, are expected to enhance the removal efficiency of EfOM and even make it feasible to selectively remove undesirable fractions/compounds from bulk EfOM.

효소 고정화막의 응용에 대한 총설 (Zeolite Based Membrane for Removal of Ammonium: A Review)

  • 이주엽;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제32권3호
    • /
    • pp.173-180
    • /
    • 2022
  • 음용수 속 암모니아의 존재는 인간의 건강에 매우 해롭다. 농작물에서의 비료 사용, 산업 폐수, 화석 연료의 연소와 같은 활동으로 인해 가용성 암모니아는 지하수를 오염시킨다. 물에 존재하는 암모니아 농도가 낮더라도 해양생물 등의 수생환경을 훼손한다. 막 기술은 암모니아를 물로부터 효과적으로 제거하기 위한 매우 중요한 과정이다. 평평한 시트 막, 막 접촉기, 그리고 막 증류법은 암모니아를 제거하여 물을 정화하는 데 사용되는 방법들 중 하나이다. 막 접촉기는 막 증류법과는 달리 상변화 없이 액체와 가스 간의 또는 액체와 액체간의 질량 전달을 통해 암모니아를 제거하는 효율적인 공정이다. 다만 이 방법은 pH가 매우 높아 암모니아 제거에 비용이 많이 든다. 제올라이트는 우수한 이온 교환 능력을 가지고 있는데, 이는 암모니아와의 상호작용을 향상시켜 폐수로부터 흡착하는 능력을 향상시킨다. 제올라이트를 함유한 혼합 매트릭스 막은 암모니아 흡착 및 폐수로부터의 분리 효율을 향상시킨다. 이 리뷰에서는 위에서 소개된 내용이 자세히 논의될 것이다.

기체확산층의 미세다공층 침투 깊이에 따른 고분자 전해질형 연료전지의 내구성능 저하 분석에 관한 연구 (Study on the Durability Characteristics of the PEM Fuel Cells having Gas Diffusion Layer with Different Micro Porous Layer Penetration Thicknesses)

  • 박재만;오환영;조준현;민경덕;이은숙;정지영
    • 한국수소및신에너지학회논문집
    • /
    • 제24권3호
    • /
    • pp.216-222
    • /
    • 2013
  • Durability characteristics of Gas Diffusion Layer(GDL) is one of the important issues for accomplishing commercialization of Proton Exchange Membrane Fuel Cell(PEMFC). It is strongly related to the performances of PEMFC because one of the main functions of GDL is to work as a path of fuel, air and water. When the GDL does not work on their proposed functions due to the degradation of durability, mass transfer in PEMFC is disturbed and it might cause the flooding phenomenon. Thus, investigating the durability of GDL is important and understanding the GDL degradation process is needed. In this study, electrochemical degradation with carbon corrosion is introduced. The carbon corrosion experiment is carried out with GDLs which have different MPL penetration thicknesses. After the experiment, the amount of degradation of GDL is measured with various properties of GDL such as weight, thickness and performance of the PEMFC. The degraded GDL shows loss of their properties.

An Improved Calculation Model for Analysis of [111] InGaAs/GaAs Strained Piezoelectric Superlattices

  • Kim, Byoung-Whi;Yoo, Jae-Hoon;Kim, Soo-Hyung
    • ETRI Journal
    • /
    • 제21권4호
    • /
    • pp.65-82
    • /
    • 1999
  • We present a calculation model for an improved quantitative theoretical analysis of electronic and optical properties of strained-piezoelectric[111] InGaAs/GaAs superlattices (SLs). The model includes a full band-coupling between the four important energy bands: conduction, heavy, light, and spin split-off valence bands. The interactions between these and higher lying bands are treated by the k ${\cdot}$ p perturbation method. The model takes into account the differences in the band and strain parameters of constituent materials of the heterostructures by transforming it into an SL potential in the larger band-gap material region. It self-consistently solves an $8{\times}8$ effective-mass $Schr{\ddot{o}}dinger$ equation and the Hartree and exchange-correlation potential equations through the variational procedure proposed recently by the present first author and applied to calculate optical matrix elements and spontaneous emission rates. The model can be used to further elucidate the recent theoretical results and experimental observations of interesting properties of this type of quantum well and SL structures, including screening of piezoelectric field and its resultant optical nonlinearities for use in optoelectronic devices.

  • PDF