• 제목/요약/키워드: Energy absorbtion capacity

검색결과 7건 처리시간 0.018초

구조적 손상을 입은 철근 콘크리트 보의 강판 휨보강 효과 (Flexual Retrofitted Effect on Structurally Damaged Reinforced Concrete Beam Strengthened with Steel Plate)

  • 임태근;김성용;신창훈;김규석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.201-210
    • /
    • 2000
  • The Rehabilitation and repair of structurally deteriorated reinforced concrete structure become more necessary as time goes by. The goal of this study is that provide the data about flexural retrofitted effect of RC beam strengthened by Steel Plate. In order to provide the data, 6 specimens were manufactured and divided with standard specimen and damaged degree A, B, C. Division of damaged A, B, C is based on deflection and degree of crack. In the determination of deflection and degree of crack, we loaded standard specimen to failure under two-point bending to find yielding load and failure load, and then we found deflections and degree of crack that correspond to 75%, 100%, 105% of the yielding load of standard specimen respectively. When we are compared with standard specimen and strengthened specimens, we founded from the experimental results that flexural capacity of structurally damaged beam strengthened by Steel Plate incremented highly, ductility was decreased, and energy absorbtion capacity was almost same.

  • PDF

구조적 손상을 입은 R.C보의 휨보강 효과 (Flexural Strengthening Effect on R.C Beam with Structural Damage)

  • 김성용;한덕전;신창훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.147-156
    • /
    • 2004
  • 최근에 구조적인 손상을 입은 철근콘크리트 구조물은 내구성과 내력 향상을 위해 보수 보강이 필요하게 되었다. 본 연구에서는 철근콘크리트 보가 휨에 의해서 손상되었을 경우 손상이전의 상태로 내력복원을 할 수 있는지를 규명하고자 한다. 실험결과 기준실험체와 강판 탄소섬유시트 격자탄소섬유판으로 보강한 실험체를 비교할 때, 휨내력은 상승하였고, 연성도와 에너지흡수능력도 기준실험체에 비해 큰 차이를 보이지 않아 보강재인 강판 탄소섬유시트 격자탄소섬유판(복합재)은 R.C보의 휨보강재로 매우 우수한 성능을 보유하고 있다고 판단된다.

일정축력과 반복 수평력을 받는 콘크리트충전 각형강관 기둥의 변형성능 평가 (Evaluation on Deformation Capacity of CFT Square Columns subject to Constant Axial and Cyclic Lateral Loads)

  • 지구현;최성모;김동규
    • 한국강구조학회 논문집
    • /
    • 제12권2호통권45호
    • /
    • pp.209-219
    • /
    • 2000
  • 콘크리트충전 강관구조는 합성효과에 의해 강관과 콘크리트의 단점을 상호보완하여 역학적으로 우수한 성능을 발휘할 수 있다. 그래서, 최근에는 초고층구조물시스템의 하나로 주목을 받고 있다. 본 연구의 목적은 일정축력과 반복 수평력을 받는 콘크리트 충전 각형강관기둥의 내력 및 변형성능을 평가하는 것이다. 이 실험의 변수로는 강관의 폭 두께비, 축력비, 콘크리트 강도, 하중가력방법과 콘크리트의 충전유무로 정하여 총 16개의 실험체를 제작하여 실험하였다. 실험결과로부터 실험체의 최대내력, 초기강성 및 변형성능에 대해 검토하였다.

  • PDF

주철근 겹침이음 및 횡철근 상세에 따른 철근콘크리트 다주교각의 거동특성에 관한 실험적 연구 (An Experimental Study on the Behavior of Reinforced Concrete Multi-Column Piers with Different Longitudinal and Transverse Reinforcement Details)

  • 김재관;김익현;김정한;조대연
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.211-219
    • /
    • 2002
  • This study is performed to investigate the behavior of multi-column piers and to evaluate the seismic performance. In this study, 3 types of scale model piers with 2-column are designed and tested by quasi-static load in both longitudinal and transverse directions. Each type of model consisting of 2 specimens has different reinforcement details in the lap splice of longitudinal bars and amount of transverse reinforcements. This paper reports that the ductility of the model in transverse direction is rather higher than in longitudinal direction because of formation of several plastic hinges and that the ultimate displacement and the energy absorbtion capacity are enhanced by using continuous longitudinal bars instead of lap-splice ones. And it is confirmed that relatively large amount of ductility can be achieved by providing sufficient lap-splice length and transverse reinforcements with end hook even if longitudinal bars are lap spliced in the base of pier.

  • PDF

Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 전단기둥의 보강성능 평가 - (Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening performance of Reinforced Concrete Shear Columns -)

  • 이강석;변인희;손영선;이문성;이성호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.137-140
    • /
    • 2006
  • In this study, a seismic performance of reinforced concrete columns strengthened by a sprayed fiber reinforced polymer (SFRP) is investigated. For this purpose, six column specimens approximately scaled into 2/3, are designed and tested under a constant axial load, 10% of the nominal axial strength of column, and pseudo-static reversed cyclic lateral loading system. Four specimens are strengthened by Sprayed FRP using different combinations of short fibers (carbon or glass fiber) and resins (epoxy or vinyl esther). For comparison, the test investigated in this study also includes a specimen strengthened using carbon fiber reinforced polymer (CFRP), and also a control specimen without strengthening. The results revealed that specimens strengthened using SFRP showed a improved structure behavior, compared to control specimen, in terms of strength, ductility, lateral drift capacity, and energy-absorbtion capacity. In addition, compared to the specimen strengthened using CFRP, Sprayed FRP-strengthened specimens reasonably showed a equivalent seismic performance.

  • PDF

Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰 (A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber)

  • 류우정;한근희;최원길;이종섭;박소진
    • Korean Chemical Engineering Research
    • /
    • 제47권6호
    • /
    • pp.795-800
    • /
    • 2009
  • 본 연구는 Vortex tube 형 이산화탄소 흡수장치에서 연소배가스 중 $CO_2$ 흡수 특성을 고찰한 것이다. 연소배가스로는 석탄(유연탄)을 연료로 하는 증기발생량 12 ton/hr 규모의 순환유동층 연소보일러에서 발생한 것을 이용하였으며 이산화탄소농도는 11~13 vol% 내외이다. 흡수 용액은 MEA 20 wt%를 기준으로 AMP, HMDA, 강염기계 KOH를 혼합하였다. 본 연구의 목적은 $CO_2$ 흡수장치를 Scrubbing 방식보다 소형화하고, 흡수용액을 절감하는 것이다. 흡수장치는 연소배가스 유량 $20Nm^3/hr$를 처리할 수 있는 직경 17 mm, 길이 250 mm의 Vortex tube 형을 사용하였다. 연소배가스와 흡수용액의 혼합 분무를 통한 $CO_2$ 제거율을 측정하였다. 실험조건은 흡수용액 농도(20~50 wt%), 흡수용액 유량(1.0, $3.0{\ell}/min$)과 연소배가스 유량($6{\sim}15Nm^3/hr$)을 변화시켰다. 결과적으로, MEA에 HMDA를 혼합한 흡수용액의 $CO_2$ 제거율이 가장 우수(약 43% 제거율)하였으며, Vortex tube 장치에서 고속유동의 기 액 접촉효과 및 기 액 분리 특성을 이용하여 $CO_2$ 흡수가 가능하였다. 그러나 $CO_2$ 흡수 효율 향상을 위한 추가적인 공정개발이 요구된다.

CFRP 시트 및 강섬유로 보강된 RC 보의 충격저항 성능 평가 (Impact Resistance Evaluation of RC Beams Strengthened with Carbon FRP Sheet and Steel Fiber)

  • 조성훈;민경환;김윤지;윤영수
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.719-725
    • /
    • 2010
  • 최근 콘크리트 구조물에 충격하중, 폭발하중 등 극한의 외력이 작용하는 경우가 빈번하게 발생하고 있다. 이 연구에서는 강섬유보강 RC보와 carbon FRP 시트를 이용하여 보강한 RC보를 이용하여 충격실험을 진행하였다. 강섬유보강 RC보의 경우 0.75%부피비로 강섬유를 혼입하였으며 carbon FRP 시트의 경우 에폭시 레진을 이용하여 보강을 한후 보 부재를 완성하였다. FRP 시트 보강은 부재의 하단을 휨 보강하였으며 충격하중이 부재에 작용할 때 발생하는 shear-plug 균열을 제어하기 위하여 충격하중이 가해지는 국부에 CFRP 전단보강을 실시하였다. 실험진행은 drop-weight test 방식으로 직접 기기를 만들어 실행하였다. 각각의 부재에 단계별로 충격하중을 가하여 실험을 진행하였으며 균열과 균열폭을 측정하였다. 실험결과 강섬유보강 RC보가 일반 RC보에 비하여 균열폭 및 shear-plug 균열제어 그리고 스폴링파괴에 더 높은 성능을 나타내었다. FRP로 부재의 하단을 휨 보강한 부재의 경우 균열의 제어에 어느정도 효과를 나타내고 있으나 충격하중이 가해질 시 콘크리트와 FRP 시트의 부착면에서 박리파괴가 빠르게 진행되었다. FRP 시트로 부재의 하단과 측면을 CFRP로 휨, 전단보강한 부재의 경우 shear-plug 균열제어에 가장 높은 저항성능을 보이고 있음을 확인할 수 있었다. 하지만 충격하중이 보강이 이루어지지 않은 부분에 작용할 경우 오히려 보강이 되지 않은 RC보에 비하여 콘크리트 스폴링 파괴에 더 취약함을 알 수 있었다.