• Title/Summary/Keyword: Energy Use Monitoring

Search Result 264, Processing Time 0.031 seconds

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

A Study on Unified Security Management System for remote data acquisition of New and Renewable Energy Facilities (신.재생에너지 발전설비의 원격 데이터 수집을 위한 통합 보안 관리시스템에 관한 연구)

  • Kim, Hyoung-Ju;Lim, Jung-Yol
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.186-193
    • /
    • 2009
  • Development and diffusion of a new and renewable energy are acutely required at domestic energy actualities to be inferior as industrialization is accelerated, and use of information electric appliance is increased rapidly. For the diessemination and practical use of new and renewable energy, this paper presents an unified security management system that is efficiently able to acquire operational status date and control distributed generation facilities. Also, the unified security management system is suggested to protect gathered operational status date from unpredictable problems such as computer virus, spy ware, and any other network problems.

  • PDF

Internet-Based Control and Monitoring System Using LonWorks Fieldbus for HVAC Application

  • Hong, Won-Pyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1205-1210
    • /
    • 2004
  • The 4-20mA analog signal used in the various industrial fields to interface sensor in distributed process control has been replaced with relatively simple digital networks, called "fieldbus, and recently by Ethernet. Significant advances in Internet and computer technology have made it possible to develop an Internet based control, monitoring, and operation scheduling system for heating, ventilation and air-conditioning (HVAC) systems. The seamless integration of data networks with control networks allows access to any control point from anywhere. Field compatible field devices become so-called "smart" devices, capable of executing simple control, diagnostic and maintenance functions and providing bidirectional serial communication to higher level controller. The most important HVAC of BAS has received nationwide attention because of higher portion of more than 40% in building sector energy use and limited resources. This paper presents the Internet-based monitoring and control architecture and development of LonWorks control modules for AHU (air handling units) of HVAC in viewpoint of configuring BAS network. This article addresses issues in architecture section, electronics, embedded processors and software, and internet technologies.

  • PDF

Ubiquitous Networking based Intelligent Monitoring and Fault Diagnosis Approach for Photovoltaic Generator Systems (태양광 발전 시스템을 위한 유비쿼터스 네트워킹 기반 지능형 모니터링 및 고장진단 기술)

  • Cho, Hyun-Cheol;Sim, Kwang-Yeal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1673-1679
    • /
    • 2010
  • A photovoltaic (PV) generator is significantly regarded as one important alternative of renewable energy systems recently. Fault detection and diagnosis of engineering dynamic systems is a fundamental issue to timely prevent unexpected damages in industry fields. This paper presents an intelligent monitoring approach and fault detection technique for PV generator systems by means of artificial neural network and statistical signal detection theory. We devise a multi-Fourier neural network model for representing dynamics of PV systems and apply a general likelihood ratio test (GLRT) approach for investigating our decision making algorithm in fault detection and diagnosis. We make use of a test-bed of ubiquitous sensor network (USN) based PV monitoring systems for testing our proposed fault detection methodology. Lastly, a real-time experiment is accomplished for demonstrating its reliability and practicability.

Power System Fault Monitoring System using Wavelelet Transform and GPS for Accurate Time Synchronization (웨이블릿 변환과 GPS 정밀시각동기를 이용한 전력계통 고장점 모니터링 시스템에 관한 연구)

  • Kim, Gi-Taek;Kim, Hyuck-Soo;Choi, Jung-Yong
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.105-110
    • /
    • 2001
  • A continuous and reliable electrical energy supply is the objective of any power system operation. A transmission line is the part of the power system where faults are most likely to happen. This paler describes the use of wavelet transform for analyzing power system fault transients in order to determine the fault location. Synchronized sampling was made possible by precise time receivers based on GPS time reference, and the sampled data were analyzed using wavelet transform. This paper describes a fault location monitoring system and fault locating algorithm with GPS, DSP processor, and data acquisition board, and presents some experimental results and error analysis.

  • PDF

A study on the basic test for the development of the wireless sensor monitoring system of the railroad vehicle (철도차량 무선 센서 모니터링 시스템 개발을 위한 기초연구)

  • Kim, Jae-Hoon;Oh, Jae-Geun;Park, Jun-Seo;Kim, Hyung-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.291-295
    • /
    • 2009
  • We did the blooth module test as a pre-test of wireless sensor monitoring system, which for the improving of on-condition maintenance reliability, on the train. In this test, we examined the communication environment of wireless sensor monitoring system by the acceleration date and frequency date in the real train structure during the operation. Also based on this results, we did the experimental verification of the sensor power system which use piezoelectric energy conversion technology by the theoretical modeling for the applying on the train on-condition maintenance.

  • PDF

A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems (독립형 태양광 발전소의 연 축전지 모니터링장치 개발)

  • Moon, Chae-Joo;Kim, Tae-Gon;Chang, Young-Hag;Kjm, Eui-Sun;Lim, Jung-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

Saemangeum feasibility study for offshore wind in yeongeunhae Remote monitoring pungryeokgecheuk (새만금 연근해의 해상풍력 타당성 조사를 위한 원격감시 풍력계측)

  • Choi, Yeon-Sung;Choi, Yong-Won;Jeon, Chil-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.3
    • /
    • pp.3-8
    • /
    • 2009
  • Environmental pollution caused by fossil fuel use and energy sources, the big concern is the rise of the current situation, one of the ways to overcome the interest in renewable energy is Gozo. Located on the west coast, especially the Saemangeum area and the northwest wind, the big advantage of the vast area that's got quite a number of wind turbines is expected. This study affirms that these expectations can be a wind energy resource survey sea area of the average wind speed of Kunsan 5 ~ 7m / s is enough, books are linked to the local marine wind farms can safely say that none of choejeokji said. In addition, the emergence of the wind resource to determine the density of the Weibull distribution is calculated using the number 1, the shape factor as a parameter to calculate the density of the wind a result, Gunsan Province was able to predict the emergence of the wind. In addition, by controlling the remote monitoring through the measurement exceeded the convenience and reliability at the same time you can achieve great results.

  • PDF

Evaluation of Loop Mediated Isothermal Amplification Based Methods for the Detection of African Swine Fever Virus from Food Waste

  • Siwon Lee;Junhwa Kwon;Su Hyang Kim;Jin-Ho Kim;Jaewon Jung;Kyung-Jin Lee;Ji-Yeon Park;Taek-Kyun Choi;Jun-Gu Kang;Tae Uk Han
    • Biomedical Science Letters
    • /
    • v.28 no.4
    • /
    • pp.334-339
    • /
    • 2022
  • African swine fever virus (ASFV) is a highly contagious and lethal pathogen that poses a threat to the global pork industry. The World Organization for Animal Health (WOAH) has placed strict surveillance measures for ASFV. The possibility of long-term survival of ASFV in raw meat or undercooked pork has been reported. Accordingly, the problem of secondary infection in food waste from households or waste disposal facilities has emerged, raising the need for ASFV monitoring of food waste. However, most of the previously reported ASFV gene detection methods are focused on clinical monitoring of pigs. There are very few cases in which their application in waste has been verified. Since ASFV diagnosis requires rapid monitoring and immediate action, loop-mediated isothermal amplification (LAMP) may be suitable, but this requires conformity assessment for LAMP to be used as a diagnostic technique. In this study, six LAMP methods were evaluated, and two methods (kit and manual) were recommended for use in diagnosing ASFV in food waste.

BEPAT: A platform for building energy assessment in energy smart homes and design optimization

  • Kamel, Ehsan;Memari, Ali M.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.321-339
    • /
    • 2017
  • Energy simulation tools can provide information on the amount of heat transfer through building envelope components, which are considered the main sources of heat loss in buildings. Therefore, it is important to improve the quality of outputs from energy simulation tools and also the process of obtaining them. In this paper, a new Building Energy Performance Assessment Tool (BEPAT) is introduced, which provides users with granular data related to heat transfer through every single wall, window, door, roof, and floor in a building and automatically saves all the related data in text files. This information can be used to identify the envelope components for thermal improvement through energy retrofit or during the design phase. The generated data can also be adopted in the design of energy smart homes, building design tools, and energy retrofit tools as a supplementary dataset. BEPAT is developed by modifying EnergyPlus source code as the energy simulation engine using C++, which only requires Input Data File (IDF) and weather file to perform the energy simulation and automatically provide detailed output. To validate the BEPAT results, a computer model is developed in Revit for use in BEPAT. Validating BEPAT's output with EnergyPlus "advanced output" shows a difference of less than 2% and thus establishing the capability of this tool to facilitate the provision of detailed output on the quantity of heat transfer through walls, fenestrations, roofs, and floors.