• 제목/요약/키워드: Energy Use Behaviors

검색결과 94건 처리시간 0.03초

자동차용 고분자전해질형연료전지 스택에서의 막-전극접합체 설계인자가 저온시동에 미치는 영향성 연구 (Analyzing the Effects of MEA Designs on Cold Start Behaviors of Automotive Polymer Electrolyte Fuel Cell Stacks)

  • 곽건희;고요한;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.8-18
    • /
    • 2012
  • This paper presents a three-dimensional, transient cold-start polymer electrolyte fuel cell (PEFC) model to numerically evaluate the effects of membrane electrode assembly (MEA) design and cell location in a PEFC stack on PEFC cold start behaviors. The cold-start simulations show that the end cell experiences significant heat loss to the sub-freezing ambient and thus finally cold-start failure due to considerable ice filling in the cathode catalyst layer. On the other hand, the middle cells in the stack successfully start from $-30^{\circ}C$ sub-freezing temperature due to rapid cell temperature rise owing to the efficient use of waste heat generated during the cold-start. In addition, the simulation results clearly indicate that the cathode catalyst layer (CL) composition and thickness have an substantial influence on PEFC cold-start behaviors while membrane thickness has limited effect mainly due to inefficient water absorption and transport capability at subzero temperatures.

Luapunov 직접법에 의한 전력계통 전압안정도 해석 (A Study on Power System Voltage Stability Analysis by the Direct Lyapunov Function)

  • 문영현;박능수;이태식
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.693-702
    • /
    • 1994
  • This paper deals with direct voltage stability analysis using a power system energy function. The structure preserved energy function is proposed as an energy function for voltage stability analysis. With the use of the proposed energy function voltage collapse conditions are derived, which yields the exactly same results with the Jacobian matrix approach. The voltage collapse phenomenon is analyzed by several methods, which shows that all of the methods produce the same voltage condition. This study also investigates the voltage collapse dynamics by using the proposed energy function. As a result, it has been found that the voltage collapse can be classified into two categories: static and dynamic instablilties which have quite different behaviors. In addition a new method is presented to calculate the power capacity limit of transmission lines with respect to voltage stability. The proposed method is tested for a 2-bus sample system, which shows the characteristics of voltage collapse phenomenon via the energy function.

HEAT-UP AND COOL-DOWN TEMPERATURE-DEPENDENT HYDRIDE REORIENTATION BEHAVIORS IN ZIRCONIUM ALLOY CLADDING TUBES

  • Won, Ju-Jin;Kim, Myeong-Su;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.681-688
    • /
    • 2014
  • Hydride reorientation behaviors of PWR cladding tubes under typical interim dry storage conditions were investigated with the use of as-received 250 and 485ppm hydrogen-charged Zr-Nb alloy cladding tubes. In order to evaluate the effect of typical cool-down processes on the radial hydride precipitation, two terminal heat-up temperatures of 300 and $400^{\circ}C$, as well as two terminal cool-down temperatures of 200 and $300^{\circ}C$, were considered. In addition, two cooling rates of 2.5 and $8.0^{\circ}C/min$ during the cool-down processes were taken into account along with zero stress or a tensile hoop stress of 150MPa. It was found that the 250ppm hydrogen-charged specimen experiencing the higher terminal heat-up temperature and the lower terminal cool-down temperature generated the highest number of radial hydrides during the cool-down process under 150MPa hoop tensile stress, which may be explained by terminal solid hydrogen solubilities for precipitation, and dissolution and remaining circumferential hydrides at the terminal heat-up temperatures. In addition, the slower cool-down rate generates the larger number of radial hydrides due to a cooling rate-dependent, longer residence time at a relatively high temperature that can accelerate the radial hydride nucleation and growth.

Direct Observation on Pyrolysis of Some Plastics

  • Takasu, Tomio;Itou, Hideyuki;Shibata, Etsuro;Kasai, Eiki;Nakamura, Takashi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.742-745
    • /
    • 2001
  • Plastics are one of difficult materials for recycling due to their characteristics in use. Recycling ratio of waste plastics was around 40% in last year in Japan, which includes energy recovery. Feed stock recycling and mechanical recycling are not easy because of additives in commercial plastics. Then, pyrolysis treatments have been done to recovery energy. Although plastics are easy to fire, complete combustion of them is not easy if anti-firing agents are added especially. Therefore, researches on pyrolysis or combustion behaviors of plastics containing additives are important from a view point recycling of plastics. Direct observation of popular plastics like polystyrene (PS), polycarbonate (PC), polyphenyle ether (PPE) and polyvinyl chloride (PVC) to investigate their pyrolysis behaviors in the present study. In case of PS, melting and gas evolution started at 9$0^{\circ}C$ and 39$0^{\circ}C$ respectively. And combustion finished at 445$^{\circ}C$. On the other hand, more than $600^{\circ}C$ and sufficient oxygen are required for complete combustion of PC and PPE.

  • PDF

Analytical simulation of reversed cyclic lateral behaviors of an RC shear wall sub-assemblage

  • Lee, Han Seon;Jeong, Da Hun;Hwang, Kyung Ran
    • Computers and Concrete
    • /
    • 제10권2호
    • /
    • pp.173-196
    • /
    • 2012
  • Experimental results of cyclic reversed lateral force test on a two-story reinforced concrete shear wall sub-assemblage are simulated analytically by using the PERFORM-3D program. A comparison of experimental and analytical results leads to the following conclusions: (1) "Shear Wall" and "General Wall" models with "Concrete shear" cannot simulate the pinching phenomena due to shear and show larger amounts of inelastic energy absorption than those in the experiment. (2) Modeling a story-height wall by using two or more "General Wall" elements with "Diagonal shear" in the vertical direction induces the phenomenon of swelling-out at the belly, leading to the erroneous simulation of shear behaviors. In application to tall building structures, it is recommended to use one element of "General Wall" with "Diagonal shear" for the full height of a story. (3) In the plastic hinge area, concrete deformations of analytical models overestimate elongation and underestimate shortening when compared with experimental results.

Single Nanoparticle Photoluminescence Studies of Visible Light-Sensitive TiO2 and ZnO Nanostructures

  • Yoon, Minjoong
    • Rapid Communication in Photoscience
    • /
    • 제2권1호
    • /
    • pp.9-17
    • /
    • 2013
  • Visible light-sensitive $TiO_2$ and ZnO nanostructure materials have attracted great attention as the promising material for solar energy conversion systems such as photocatalysts for water splitting and environmental purification as well as nano-biosensors. Success of their applications relies on how to control their surface state behaviors related to the exciton dynamics and optoelectronic properties. In this paper, we briefly review some recent works on single nanoparticle photoluminescence (PL) technique and its application to observation of their surface state behaviors which are raveled by the conventional ensemble-averaged spectroscopic techniques. This review provides an opportunity to understand the temporal and spatial heterogeneities within an individual nanostructure, allowing for the potential use of single-nanoparticle approaches in studies of their photoenergy conversion and nano-scale optical biosensing.

선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

A routing protocol based on Context-Awareness for Energy Conserving in MANET

  • Chen, Yun;Lee, Kang-Whan
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.104-108
    • /
    • 2007
  • Ad hoc networks are a type of mobile network that function without any fixed infrastructure. One of the weaknesses of ad hoc network is that a route used between a source and a destination is to break during communication. To solve this problem, one approach consists of selecting routes whose nodes have the most stable link cost. This paper proposes a method for improving the low power distributed MAC. This method is based on the context awareness of the each nodes energy in clustering. We propose to select a new scheme to optimize energy conserving between the clustering nodes in MANET. And this architecture scheme would use context-aware considering the energy related information such as energy, RF strength, relative distances between each node in mobile ad hoc networks. The proposed networks scheme could get better improve the awareness for data to achieve and performance on their clustering establishment and messages transmission. Also, by using the context aware computing, according to the condition and the rules defined, the sensor nodes could adjust their behaviors correspondingly to improve the network routing.

고낙하추 충격시험기를 이용한 스티칭된 샌드위치 복합재의 저에너지 충격거동 연구 (Impact Behaviors of Stitched Sandwich Composites Under Low Energy Impact Using Drop Weight Impact Tester)

  • 윤성호;이상진;조세현
    • Composites Research
    • /
    • 제12권5호
    • /
    • pp.54-64
    • /
    • 1999
  • 본 연구에서는 낙하추 방식의 충격시험기를 이용하여 스티칭된 샌드위치 복합재의 저에너지 충격거동을 조사하였다. 스티칭된 샌드위치 복합재는 유리섬유직물의 면재와 우레탄 폼의 코아로 구성되어 있으며 위쪽 면재와 아래쪽 면재는 폴리에스터 보강섬유로 코아의 두께방향을 따라 스티칭하여 일체형으로 결합되어 있다. 이때 코아의 두께가 충격거동에 미치는 영향을 조사하기 위해 코아의 두께를 달리한 네 종류의 스티칭된 샌드위치 복합재를 고려하였다. 스티칭된 샌드위치 복합재에 작용되는 충격조건은 낙하추의 질량과 낙하추의 낙하높이를 조절함으로써 변화시켰다. 연구결과에 따르면 코아의 두께, 낙하추의 낙하높이, 그리고 낙하추의 질량 등의 변화는 스티칭된 샌드위치 복합재에서의 충격하중, 충격체와의 접촉시간, 면재에 형성된 변형율 등에 영향을 미침을 알 수 있었다. 또한 스티칭된 샌드위치 복합재는 스티칭부의 보강효과로 인해 손상을 억제시킬 분 아니라 손상이 발생한 경우에도 구조물로서 역할을 담당할 수 있다. 그러나 스티칭된 샌드위치 복합재를 효율적으로 기존의 구조물에 적용하기 위해서는 스티칭부에서의 수지함침성을 개선할 수 있는 제작공법의 연구가 필요하다.

  • PDF

Bargaining-Based Smart Grid Pricing Model for Demand Side Management Scheduling

  • Park, Youngjae;Kim, Sungwook
    • ETRI Journal
    • /
    • 제37권1호
    • /
    • pp.197-202
    • /
    • 2015
  • A smart grid is a modernized electrical grid that uses information about the behaviors of suppliers and consumers in an automated fashion to improve the efficiency, reliability, economics, and sustainability of the production and distribution of electricity. In the operation of a smart grid, demand side management (DSM) plays an important role in allowing customers to make informed decisions regarding their energy consumption. In addition, it helps energy providers reduce peak load demand and reshapes the load profile. In this paper, we propose a new DSM scheduling scheme that makes use of the day-ahead pricing strategy. Based on the Rubinstein-Stahl bargaining model, our pricing strategy allows consumers to make informed decisions regarding their power consumption, while reducing the peak-to-average ratio. With a simulation study, it is demonstrated that the proposed scheme can increase the sustainability of a smart grid and reduce overall operational costs.