• Title/Summary/Keyword: Energy Storage System, ESS

Search Result 401, Processing Time 0.036 seconds

Integrated Operation of DC Distribution System for Building Application (빌딩에 적용되는 DC 배전 시스템의 통합 운전)

  • Han, Dong-Woo;Shin, Soo-Cheol;Lee, Hee-Jun;Won, Chung-Yuen;Lee, Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.57-58
    • /
    • 2013
  • 본 논문에서는 빌딩과 같은 건축물에 적용될 DC 배전 시스템의 통합 운전에 대하여 제안 및 분석을 하였다. 제안하는 DC 배전 시스템은 AC/DC 전력 변환 모듈 2개와 하나의 ESS (Energy Storage System) 모듈이 병렬로 연결 되어있으며, ESS와 부하의 상태에 따라 적합한 운전 모드로 동작 하게 된다. ESS와 부하의 상태는 시뮬레이션을 통해 모의하였으며, 제안된 시스템은 각 상황에 대응하는 제어가 원활히 이루어지는 것을 검증하였다.

  • PDF

Online State-of-health(SOH) estimation for a LiMn2O4 cell based on fuzzy-logic

  • Kim, Jonghoon;Nikitenkov, Dmitry;Park, Jungpil
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.447-448
    • /
    • 2013
  • This paper investigates a new approach based on the fuzzy-logic controlled methodology that is suitable for analyzing and evaluating large format $LiMn_2O_4$ cell performance via online state-of-health (SOH) estimation for energy storage system (ESS) applications. First of all, the values of the cell resistance R and maximum cell capacity $Q_{max}$ are calculated from three factors such as voltage, current, and time that were measured by discharging/charging sequence. Then, using two values R and $Q_{max}$ previously calculated, present SOH of an arbitrary $LiMn_2O_4$ cell can be estimated using the defined fuzzy-logic inference system. The main advantage of this approach is wide parameters tuning possibility for good correspondence of SOH decay with other accurate estimation method and the possibility to perform suitable online SOH estimation.

  • PDF

The Study of Grid Fault Detection for Sag, Swell (Sag와 Swell에 따른 계통 이상 검출에 관한 연구)

  • Kim, Min-Gi;Noh, Yong-Su;Kim, Jun-Gu;Jung, Yong-Chae;Won, Chun-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

1MW EV Fast Charging System based on SST Technologies (SST 기술 기반 1MW 전기차 급속충전 시스템)

  • Cho, Hyoung Yeon;Seo, Haewon;Byen, Byeng Joo;Kim, Jae Hyuk;Kim, Sung Joo;Jeong, Byung Hwang;Kim, Ho-Sung;Baek, Ju-Won
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.278-279
    • /
    • 2020
  • 최근 전기차 배터리는 일 주행거리 증대를 위해서 50~100 kWh 급으로 대용량화 되고 있다. 그와 동시에 충전시간 단축을 위해서 배터리 전압은 400V에서 800V로 높아지고 급속충전기 용량은 50kW에서 350kW 급으로 대용량화 되고 있다. 본 논문에서는 전기차 증가 추세에 따라 기존 주유소를 대체하는 MW급 전기차 급속충전소를 위한 에너지 저장 장치(Energy Storage System, ESS) 연계 지능형 반도체 변압기(Solid State Transformer, SST) 기술 기반의 전력변환 시스템 모델을 제안하고자 한다. 이 모델은 배전계통에 직접 연계가 가능하기 때문에 대용량 전기차 급속충전소뿐만 아니라 DC Grid 구축에 응용 가능하다.

  • PDF

SIMMER extension for multigroup energy structure search using genetic algorithm with different fitness functions

  • Massone, Mattia;Gabrielli, Fabrizio;Rineiski, Andrei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1250-1258
    • /
    • 2017
  • The multigroup transport theory is the basis for many neutronics modules. A significant point of the cross-section (XS) generation procedure is the choice of the energy groups' boundaries in the XS libraries, which must be carefully selected as an unsuitable energy meshing can easily lead to inaccurate results. This decision can require considerable effort and is particularly difficult for the common user, especially if not well-versed in reactor physics. This work investigates a genetic algorithm-based tool which selects an appropriate XS energy structure (ES) specific for the considered problem, to be used for the condensation of a fine multigroup library. The procedure is accelerated by results storage and fitness calculation speedup and can be easily parallelized. The extension is applied to the coupled code SIMMER and tested on the European Sustainable Nuclear Industrial Initiative (ESNII+) Advanced Sodium Technological Reactor for Industrial Demonstration (ASTRID)-like reactor system with different fitness functions. The results show that, when the libraries are condensed based on the ESs suggested by the algorithm, the code actually returns the correct multiplication factor, in both reference and voided conditions. The computational effort reduction obtained by using the condensed library rather than the fine one is assessed and is much higher than the time required for the ES search.

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.

Life Cycle Assessment (LCA) and Energy Efficiency Analysis of Fuel Cell Based Energy Storage System (ESS) (연료전지 기반 에너지저장 시스템의 환경 전과정평가 및 에너지 효율성 분석)

  • KIM, HYOUNGSEOK;HONG, SEOKJIN;HUR, TAK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.156-165
    • /
    • 2017
  • This study quantitatively assessed the environmental impacts of fuel cell (FC) systems by performing life cycle assessment (LCA) and analyzed their energy efficiencies based on energy return on investment (EROI) and electrical energy stored on investment (ESOI). Molten carbonate fuel cell (MCFC) system and polymer electrolyte membrane fuel cell (PEMFC) system were selected as the fuel cell systems. Five different paths to produce hydrogen ($H_2$) as fuel such as natural gas steam reforming (NGSR), centralized naptha SR (NSR(C)), NSR station (NSR(S)), liquified petroleum gas SR (LPGSR), water electrolysis (WE) were each applied to the FCs. The environmental impacts and the energy efficiencies of the FCs were compared with rechargeable batteries such as $LiFePO_4$ (LFP) and Nickel-metal hydride (Ni-MH). The LCA results show that MCFC_NSR(C) and PEMFC_NSR(C) have the lowest global warming potential (GWP) with 6.23E-02 kg $CO_2$ eq./MJ electricity and 6.84E-02 kg $CO_2$ eq./MJ electricity, respectively. For the impact category of abiotic resource depletion potential (ADP), MCFC_NGSR(S) and PEMFC_NGSR(S) show the lowest impacts of 7.42E-01 g Sb eq./MJ electricity and 7.19E-01 g Sb eq./MJ electricity, respectively. And, the energy efficiencies of the FCs are higher than those of the rechargeable batteries except for the case of hydrogen produced by WE.

Research on DC Power Simulator Considering the Battery Aging Characteristics (배터리 노화 특성을 고려한 DC전원 모의장치에 관한 연구)

  • Lee, Jong-Hak;In, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.409-410
    • /
    • 2016
  • 에너지 저장 시스템(ESS, Energy Storage System)은 태양광(PV), 풍력(WT) 등과 같은 신재생 에너지 출력안정화, 계통 전력품질 개선, 수용가 에너지효율화 등의 분야에 이용되고 있다. 에너지 저장 시스템은 전력변환장치와 에너지 저장장치로 구성되며, 에너지 저장 장치로 배터리를 많이 사용하고 있다. 전력변환장치 및 제어기의 설계 및 검증을 위해서는 배터리를 전력변환장치에 연계하여야 하지만 배터리의 경우 고가에 관리가 어렵기 때문에 일반적으로 DC전원 모의 장치를 이용한다. 또한 배터리를 사용함에 따라 노화가 진행되어 배터리 임피던스 특성이 변화해 에너지 저장 시스템의 성능에 영향을 미칠 수 있다. 본 논문에서는 에너지 저장 시스템용 전력 변환장치 및 제어기의 설계 및 현실적인 검증이 가능한 배터리 노화 특성을 고려한 DC전원 모의장치를 개발하기 위한 연구를 진행하였다.

  • PDF

The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter (계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계)

  • Koh, Kwang-Soo;Oh, Pil-Kyoung;Kim, Hee-Jung;Kim, Young-Min
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

PSIM based Modeling of a Series-Parallel Hybrid Electric Vehicle Powertrain Using Planetary Gear (PSIM기반의 유성기어를 사용한 직병렬 혼합형 하이브리드 자동차의 파워트레인 모델링)

  • Bae, Taesuk;Lim, Deokyoung;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.293-294
    • /
    • 2011
  • 본 논문에서는 유성기어를 사용한 직병렬 혼합형 하이브리드 자동차(SPHEV)의 파워트레인 모델링과 하이브리드 자동차의 모드(전기자동차 모드(EV), 엔진 모드, 하이브리드 모드(HEV) 등등)변화에 따른 파워 분배 및 동특성 해석에 대하여 기술한다. 내연기관, 전동기, Energy Storage System(ESS)과 같은 구성요소들의 정격은 에너지 개념과 Electrical Peaking Hybrid(ELPH)를 이용하여 설계하였으며, 동특성 분석을 위하여 전력전자 분야 에서 널리 사용되고 있는 시뮬레이션 툴인 PSIM을 이용하여 모델링 하였다.

  • PDF