• Title/Summary/Keyword: Energy Standard

Search Result 3,170, Processing Time 0.031 seconds

Power performance Testing of Small Wind Turbine Generator System (소형 풍력발전시스템의 출력성능검사)

  • Kim, Hyeon-Ki;Kim, Byeong-Min;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

Can the Energy Costs of Speech Movements be Measured\ulcorner A Preliminary Feasibility Study

  • Bjorn Lindblom;Moon, Seung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.3E
    • /
    • pp.25-32
    • /
    • 2000
  • The main question addressed in this research was whether an adaptation of a standard exercise Physiology Procedure would be sensitive enough to record excess oxygen uptake associated with speech activity. Oxygen consumption was recorded for a single subject during 7-minute rest periods and an automatic speech task, also 7-minutes long and performed at three different vocal efforts. The data show measurable and systematic speech-induced modifications of breathing and oxygen uptake patterns. The subject was found to use less power for normal than for soft and loud speech. This result is similar to findings reported by experimental biologists on the energetics of locomotion. However, more comprehensive feasibility studies need to be undertaken on a larger population before solid and detailed conclusions about speech energy costs are possible. However, it appears clear that, for experimental tasks like the present one, i.e., variations in vocal effort, standard exercise physiology methods may indeed offer a viable approach to recording excess oxygen uptake associated with speech movements.

  • PDF

Utilization and Quality Standard of Fast Pyrolysis Bio-Oil (급속 열분해 바이오 오일의 활용 및 품질기준)

  • PARK, JO YONG;DOE, JIN-WOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.2
    • /
    • pp.223-233
    • /
    • 2020
  • Fast pyrolysis is one of the most promising technologies for converting biomass to liquid fuels. Pyrolysis bio-oil can replace petroleum-based fuels used in various thermal conversion devices. However, pyrolysis bio-oil is completely different from petroleum fuels. Therefore, in order to successfully use pyrolysis bio-oil, it is necessary to understand the fuel characteristics of pyrolysis bio-oil. This paper focuses on fuel characteristics and upgrading methods of pyrolysis bio-oil and discusses how these fuel characteristics can be applied to the use of pyrolysis bio-oils. In addition, the fuel quality standards of fast pyrolysis bio-oil were examined.

A Consideration for a Protocol Supporting Tire Pressure Monitoring System (타이어 압력 모니터링 시스템의 호환성을 지원하는 프로토콜 고찰)

  • Bae, Byoung-Chul;Seo, Hae-Moon;Lee, In-Soo;Nam, Yoon-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.6
    • /
    • pp.335-344
    • /
    • 2011
  • The Tire Pressure Monitoring System(TPMS) is often used recently. However, the standards and functions are very different. Even though the regulation requires all vehicles install the TPMS, there is no a standard of a Physical and Media access control protocol which provides compatibility with other systems. In this paper, we propose a MAC protocol based on the international standard and an energy efficient hybrid RF system platform. The MAC protocol provides compatibility of the TPMS with other systems and the RF system platform reduces energy consumption significantly.

A Study on Explosive Hazardous Areas in Hydrogen Handling Facility (수소 취급설비의 폭발위험장소에 관한 연구)

  • PYO, DON-YOUNG;LIM, OCK-TAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Safety of hydrogen handling facilities is needed as supply of hydrogen cars has been expanded recently. In this study, the adequacy of safety regulations of hydrogen handling facilities and the risk of damage with hydrogen leakage were studied. The range of explosion hazard location of the hydrogen filling plant was investigated using the computational fluid dynamics (CFD) method, Explosive hazardous area is influenced by leakage type, hole size and sectional area. When the conditions of KS standard are applied, range explosive hazardous area is expanded 7.05 m, maximum. It is about 7 times larger than exceptional standard of hydrogen station. Meanwhile, distance from leakage point to 25% LEL of hydrogen is investigated 1.6 m. Considering the shape of charging hose, regulation of hydrogen station is appropriate.

Feasibility Study on Leveling Method of Electric Power Load by Applying Thermal Storage Air Conditioning System (축열식 열원시스템 적용에 의한 전력부하 평준화의 경제성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Reducing global warming potential has become important, and as one of those methods for reducing it, economic evaluation by applying ice thermal storage air conditioning system was performed. The floor area and height of the subject building was assumed $5,000m^2$ and 20 m. Absorption chillerheater system and air source heat pump system was used for comparing to the subject system, and payback period method was used to perform economic evaluation. Although the running cost of ice thermal storage system is reduced compared to two systems, the ratio is not significant compared to the increase of initial construction expenses, and payback period was calculated to be about 7.7 and 79.3 years. However, the heat storage system should be approached from the viewpoint of long term rather than the economic standard in the present standard.

Study on Standard Operating Conditions for Office Buildings (사무소 건물의 표준운전상태에 관한 연구)

  • Park Sang Dong;Oh Chang Sup;Won Joung Son;Tae Choon Seup
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.1
    • /
    • pp.48-63
    • /
    • 1984
  • Standard Building Operation Conditions(SBOC) is to describe typical conditions under which a building would operate during the coulee of a day In order to develop SBOC profiles for office building, we surveyed the operating conditions of randomly selected 20 existing office buildings in Seoul by means of enquetes, and made SBOC profiles. SBOC profiles consist of human occupancy profile, light ins usage profile, system schedule and domestic hot water profile etc. SBOC profiles will be used as input data of DOE-2 computer program to estimate DER(Design Energy Requirements) and to develop EBL (Energy Budget Level), SBOC profiles are not meant to be exact description of how a building will actually be used by its respective users. Rather they are intended to be reasonable typical project ions of how buildings might be used.

  • PDF

Trend of Industry and Standard related to Offshore Cable for Offshore Wind Farm (해상풍력용 해저케이블 산업 및 기술기준 동향)

  • Kim, Kyung-Hwa;Song, Yong-Un;Kim, Mi-Young;Kim, Mann-Eung
    • Journal of Wind Energy
    • /
    • v.3 no.2
    • /
    • pp.11-17
    • /
    • 2012
  • An offshore(submarine) cable has been used for more than a century, however it has been used mainly for communication or power supply to near-shore island. Therefore, offshore cable has not been got more attention than other types of cable and the related standards have also not been established well. However wind farms have been shifting from land to offshore because of better wind condition. Consequently, it has been pushing up demand for offshore cable. Hence, this paper introduces the trend of offshore cable industry and related standards or recommendations only focusing on offshore wind farm. In details, the installed offshore cables in offshore wind farms, the main offshore cable makers and up to date technologies are covered. In addition, the related standards or recommendations are also analyzed and compared each other.

Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings - (교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 -)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

Analysis of Power Supply Cost According to Nuclear and Renewable Energy Policies (원전 및 신재생에너지 정책에 따른 전력공급비용 분석)

  • Woo, Pil Sung;Kim, Kang-won;Hwang, Soon-hyun;Kim, Balho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.16-21
    • /
    • 2018
  • As a result of the Fukushima disaster and climate change due to excessive greenhouse gases, international energy affairs are currently focused on establishing safe and environment-friendly policies. To achieve this, Republic of Korea has established a plan for environment-friendly energy supplies. It is expected that policy enforcement will be accompanied by an increase in energy supply costs. An analysis of energy supply costs is necessary before the establishment of any national energy policy. This paper analyzes and compares the energy supply costs accompanying environmental and nuclear energy policies, based on the Korean National Energy Master Plan and the Basic Plan for Long-Term Electricity Supply and Demand, in order to understand the implications of these national energy policies.