• Title/Summary/Keyword: Energy Standard

Search Result 3,170, Processing Time 0.027 seconds

A NOTE ON ENERGY MINIMIZING MAP ON MANIFOLD WITH ISOLATED PEAKS

  • SHIN, HEAYONG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.6 no.1
    • /
    • pp.59-65
    • /
    • 2002
  • In this paper, we consider some homogeneous maps from a cone over 2-spheres and determines whether they become energy minimizing maps or not. In fact, any homogeneous map from a standard cone over 2-sphere of radius smaller than 1 can not be a minimizing harmonic map.

  • PDF

Improving Assessment of External Environment for Green Standard for Energy & Environmental Design Certification according to Climate Change (기후변화에 따른 녹색건축인증제도의 외부환경 평가항목 개선방향 연구)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Song, Ok-Hee
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.171-180
    • /
    • 2017
  • In 1990s, as the extreme weather events according to the global warming climate change are occurred frequently all around the world and the scale of the damage increases, the developed countries are promoting various policies for reducing greenhouse gas emissions setting the goal of greenhouse gas reduction with the level of State and local government. Especially for the greenhouse gas reduction of buildings and the inducement of eco-friendly design, the green certification system is strengthened with the assessment of energy and greenhouse management, and recently, according to the policy change of climate and energy, the certification system expanded from the buildings to the level of city and district is piloted. So this research is to understand the main contents and the assessment system of domestic green building certification system implemented in March 2013 in response to the policy change of climate and energy and to suggest the basic data for the improvement of present domestic greenhouse certification standard through the analysis of actual certification and the main case analysis of international green certification system. Recently in developed countries, in 1990s, for the reduction of building's greenhouse gas emission and the inducement of eco-friendly design, from the building of LEED, BREEAM, DGNB to the level of city and district such as LEED Neighborhood Development, BREEAM Communities, DGNB Stadtquartiere, the system is expanded and piloted. On the contrary, as for the domestic standard of green building certification system, the distribution ratio according to the assessment items in each category consists of the assessment system based on the buildings, and just the simple adjustment of some items and the improvement of weighted value are performed. Actually, as a result of selecting the 30 districts of apartment housing with the most certification performance by use among the 49 buildings certified by Institute of Land & Housing from December 2014 to July 2016 and analyzing the assessment score, the certification level is determined by the sectors of high distribution like indoor environment and energy not by the ineffective sector of external environment with low distribution so this system has a limitation to perform the practical means for the policy change of climate and energy. Thus for the national green building certification standards, the assessment system in the sector of external environment is to complemented and furthermore, reflecting domestic reality, through the introduction of certification system and the assessment system with the level of city and district, this system should be improved to meet the international certification standard.

Study on Adsorption Kinetic of Amaranth Dye on Activated Carbon (활성탄에 의한 아마란스 염료의 흡착동력학에 관한 연구)

  • Lee, Jong-Jib
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • The adsorption characteristics of amatanth dye by granular activated carbon were experimently investigated in the batch adsorption. Kinetic studies of adsorption of amaranth dye were carried out at 298, 308 and 318 K, using aqueous solutions with 100, 200 and 300 mg/L initial concentration of amatanth. It was established that the adsorption equilibrium of amaranth dye on granular activated carbon was successfully fitted by Langmuir isotherm equation at 298 K. The pseudo first order and pseudo second order models were used to evaluate the kinetic data and the pseudo second order kinetic model was the best with good correlation. Values of the rate constant ($k_2$) have been calculated as 0.1076, 0.0531, and 0.0309 g/mg h at 100, 200 and 300 mg/L initial concentration of amatanth, respectively. Thermodynamic parameter such as activation energy, standard enthalpy, standard entropy and standard free energy were evaluated. The estimated values for standard free energy were -5.08 - -8.10 kJ/mol over activated carbon at 200 mg/L, indicated toward a spontaneous process. The positive value for enthalpy, 38.89 kJ/mol indicates that adsorption interaction of amatanth dye on activated carbon is an endothermic process.

Standard Transfer Free Energy of Sodium and Cupric Ions in Water-Acetylacetone Solvent System (물-아세틸아세톤 용매계에서 나트륨이온과 구리이온의 표준이동 자유에너지)

  • Lee Heung Lark;Park Jong-Taek
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.632-637
    • /
    • 1992
  • Standard transfer free energies of sodium and cupric perchlorates in water-acetylacetone solvent system have been determined by electromotive force measurements of galvanic cell and these energies of sodium and cupric ions in this solvent system have been evaluated by the tetrabutylammonium tetraphenylborate assumption as the extrathermodynamic procedure. Standard transfer free energy values of sodium and cupric ions from water to acetylacetone solvent were 5.09 and 4.16 kcal/mol at 25${\circ}C$, respectively. These values mean that acetylacetone is much weaker donor solvent to sodium and cupric ions than water. The standard transfer free energy value of cupric ion from water to mixture solvents which contain small amount of acetylacetone is changed by an unusual form. This is because of the chelate formation effect of acetylacetone to cupric ion.

  • PDF

A Generating Cost Evaluation of APR+ Standard Design (APR+ 표준설계 발전원가 분석)

  • Ha, Gag-Hyeon;Kim, Sung-Hwan;Lee, Jae-Ho
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.236-239
    • /
    • 2014
  • KHNP CRI has been developing APR+ nuclear power plant since 2007, which is GEN III+ model with 1500 MWe capacity. To develop safer and more economical nuclear power plant than APR1400, we investigated advanced design features of ALWR(advanced light water reactor) being constructed in Korea and being developed/constructed in foreign countries. We applied the advanced design features and lessons learned from Fukushima accident to develop APR+ standard design suitable for both domestic construction and overseas construction business. Three economic assessments have performed during standard design phase of APR+. The result of the 3th(final) economic analysis for APR+ standard design showed that APR+ N-th plant was about 23% more economical than coal-fired 1,000MW power plant.

Development of KEPCO e-IoT Standard Type oneM2M Gateway for Efficient Management of Energy Facilities (에너지 설비의 효율적 관리를 위한 한전 e-IoT 표준형 oneM2M Gateway 개발)

  • Sim, Hyun;Kim, Yo-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1213-1222
    • /
    • 2021
  • This study is a digitalization study based on ICT technology as part of the development of innovative technologies in the new energy industry as a 2050 carbon-neutral policy. It is the development of an oneM2M-based IoT server platform that can be integrated and managed in conjunction with the external interface of each energy facility. It analyzes KEPCO's e-IoT standard specifications through the Power Research Institute's 'SPIN' and develops representative standards, LWM2M and oneM gateway platforms. OneM2M secures and analyzes the recently announced standard for Release 2 instead of the existing Release 1. In addition, the e-IoT standard oneM2M platform is developed based on R2. In addition, it selects the specifications for e-IoT gateway devices that can sufficiently implement KEPCO's e-IoT standards. In addition, a technology and system for developing a high-performance gateway device that considers future scalability were proposed.

Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction

  • Kyungsoo Bae;Dong Yul Oh;Il Dong Yun;Kyung Nyeo Jeon
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.139-149
    • /
    • 2022
  • Objective: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists' performance for pulmonary nodule detection on chest radiographs (CXRs). Materials and Methods: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed. Results: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules. Conclusion: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists' performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required.

A study on the effect of discharge in a multiple spark ignition engine (다회수 스파크 점화기관의 방전효과에 관한 연구)

  • 이성열;한병호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.55-64
    • /
    • 1989
  • The effect of discharge have been investigated for condition of spark in a multiple spark ignition engine, as the spark duration, capacitive and inductive discharge energy were calculated for condition of spark by ignition wave and energy formula. The useful portion of spark discharge is divided into capacitance portion and inductance portion. It was found that capacitive discharge energy and spark duration were increased according to increasing number of spark, and inductive discharge energy was increased according to increasing spark interval. Therefore engine torque was increase and lean misfire limit was extended comparing with the standard ignition system. It found that spark energy was discharged within ignition delay period availability acted on the formation and growth of flame kernel, and total spark energy was increased according to increasing number of spark times, but discharged spark energy after ignition delay became unavailable energy. And the capacitive discharge energy has the dominant effect for stoichiomeric or not very rich air-fuel mixture but inductive discharge energy has the dominant effect for lean air-fuel mixture.

  • PDF

A Suitability Analysis on the legal standards of the Rural Housing Standard Plans (농촌주택 표준설계도의 관련 법적 기준에의 적합성 분석 연구)

  • Jeon, Young-Hoon;Shin, Doo-Sik
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • The Rural Housing Standard Plans for improving the quality of life and housing stability in rural areas has been developed 87 types from 1994 to 2012. However, some types of Plans do not satisfy the current legal standard in accordance with social and legal changes. Standard plans has the same effect as a building permit, and replace it, so legal suitability of Plans is an important. Therefore, it is required the suitability analysis on the legal standards of Rural Housing Standard Plans. The Purpose of this study is to derive improper types and items of the Rural Housing Standard Plans on the legal standards. In this study, we analyzed its suitability on the legal standards(law on fire-fighting system installation and safety management, energy saving design criteria for buildings, structural checklist for small buildings, the types of drawing for building permit) in accordance with "rules for the operation of standard plans". And we analyzed the utilization of the Rural Housing Standard Plans through downloads from welchon portal.

Comparative Analysis of Accumulated Temperature for Seasonal Heating Load Calculation in Greenhouses (온실의 기간난방부하 산정을 위한 난방적산온도 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.192-198
    • /
    • 2014
  • To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather data are required. However, they are being provided only at seven regions in Korea. So, instead of using standard weather data, in order to find the method to build design weather data for seasonal heating load calculation, heating degree-hour and heating degree-day were analyzed and compared by methods of fundamental equation, Mihara's equation and modified Mihara's equation using normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equation using thirty years hourly weather data showed a good agreement with them using standard weather data. The 24 times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heating load. And to conclude, in regions which are not available standard weather data, we suggest that design weather data should be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data for energy estimation.