• 제목/요약/키워드: Energy Standard

검색결과 3,170건 처리시간 0.024초

Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber

  • Yu, Jili;Wu, Jinjie;Liao, Zhenyu;Zhou, Zhenjie
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1466-1472
    • /
    • 2018
  • A key comparison has been made between the air-kerma standards of the National Institute of Metrology (NIM), China, and other Asia Pacific Metrology Programme (APMP) members in the medium-energy X-ray. This paper reviews the primary standard Free-air ionization chamber correction factor experimental method and Monte Carlo simulation method in the NIM. The experimental method and the Monte Carlo simulation method are adopted to obtain the correction factor for the medium-energy X-ray primary standard free-air ionization chamber at 100 kV, 135 kV, 180 kV, 250 kV four CCRI reference qualities. The correction factor has already been submitted to the APMP as key comparison data and the results are in good agreement with those obtained in previous studies. This study shows that the experimental method and the EGSnrc simulation method are usually used in the measurement of the correction factor. In particular, the application of the simulation methods is more common.

Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

  • Nam, Uk-Won;Lim, Chang Hwy;Lee, Jae Jin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Park, Youngsik;Kim, Hyun Ok;Moon, Myungkook;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.107-112
    • /
    • 2013
  • Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS). The prototype TEPC which can simulate a 2 ${\mu}m$ of the site diameter for micro-dosimetry has been tested with a standard alpha source ($^{241}Am$, 5.5 MeV). Also, the calibration of the TEPC was performed by the $^{252}Cf$ neutron standard source in Korea Research Institute of Standards and Science (KRISS). The determined calibration factor was $k_f=3.59{\times}10^{-7}$ mSv/R.

업무용 건축물의 녹색건축 인증등급별 평가항목 득점에 관한 연구 (A Study on the Score of Issues by Certification Grade in the G-SEED for Office Buildings)

  • 황선영;태춘섭;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.9-18
    • /
    • 2016
  • G-SEED(Green Standard for Energy and Environmental Design) is the certification system to evaluate environmental friendliness of buildings for the purpose of reducing environmental burden generated from the entire process of buildings, which is classified into 4 grades according to the evaluated score. Green building certification rule regulate to get over green 2nd grade for the public office buildings of $3000m^2$ or more. However, detailed measures on the applied level of each issue to obtain targeted certification grade have not been prepared yet. For each issue, the score distribution and the ratio of score in proportion to credit were analyzed by certification grade for office buildings which get the G-SEED certification. And applied level of issues were presented for each certification grade.

바이오부탄올, 바이오에탄올 혼합비율에 따른 연료적 특성 연구 (Study on Fuel Characteristics Depending on Mixing Ratio of Bio-Butanol and Bio-Ethanol)

  • 김신;김재곤;박천규;하종한
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.704-711
    • /
    • 2017
  • Korea, which has a high dependency on energy imports, is greatly affected by fluctuations in international oil prices. In order to offset these effects, various policies such as 'diversification of energy sources' and 'energy mix' are being pursued. Renewable Fuel Standard (RFS) is a policy promoted for this purpose, and a compulsory mixing system is applied only to the diesel. In order to reduce dependence on fossil fuels in various countries, they are concentrating on the dissemination of bio-alcohol as well as bio-diesel, and commercialization through various verification. In this study, evaluation of domestic materials and vehicles was carried out to promote domestic bio alcohol fuel. We analyzed the fuel characteristics of domestic quality standard items by mixing them with gasoline of automobile at a certain mixing ratio (0%, 3%, 6%, and 10%).

PV모듈 발전성능 비교시험과 계측편차 요인 분석 (Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module)

  • 강기환;김경수;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

IEC 61400 풍력표준을 적용한 제주도 김녕 난류강도 특성분석 (Analysis on Turbulence Intensity Characteristics at Gimnyeong, Jejudo by Applying IEC 61400 Wind Turbine Standards)

  • 김현구;정태윤;장문석
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.59-65
    • /
    • 2010
  • Analysis on turbulence intensity profile depending on wind speed is an important process to set up design condition of wind turbine in terms of fatigue load. This paper tests goodness of fit of turbulence intensity empirical equations suggested by the IEC 61400 Standards with Jejudo Gimnyeong met-tower measurement, which is erected at a seashore. Therefore sea breeze and land breeze coexist. Sea breeze case showed apparent increasing trend of turbulence intensity in a high wind speed regime due to increase of sea surface roughness. However, neither inland wind turbine standard IEC 61400-1 nor offshore wind turbine standard IEC 61400-3 fit such a trend adequately. On the other hand, the modified empirical equation of turbulence intensity of IEC 61400-3 derived from Germany FINO1 application study by considering turbulence intensity behavior in a high wind speed regime showed good agreement with the measurement. Therefore, we can reconfirm and conclude that IEC 61400-3 Ed.1 legislated in 2009 needs to be modified.

전기제품 에너지 소비효율의 통계적 양산 관리 방법에 대한 연구 (A Study on the Statistical Production Control of Energy Efficiency in Electric Product)

  • 전영호;김성돈
    • 한국경영공학회지
    • /
    • 제23권4호
    • /
    • pp.73-86
    • /
    • 2018
  • Most electric products produced during the manufacturing process are produced after design and mass production under a given control standard. In particular, the development phase should present the criteria for the production process by setting appropriate limits based on the performance being targeted. Even if the standard of performance is set considering the performance of the process, measuring the performance of the product after actual production results will cause nonconformities with the expected results. Among the performance of electrical products, Energy standards represented by energy consumption efficiency continue to be of importance, and are mandatory standards that correspond to national standards in most countries. Therefore, statistical quality control of these standards shall basically have a large number of test equipment for each product, ensure sufficient test time and continuous sampling of product samples. In the end, companies that produce and sell electric appliances are striving to control mass production at a great cost, but this is not acceptable. This study presents basic characteristics of the energy efficiency of electrical products and proposes and conducts a case study on statistical production control methods for performance variation across products under the standards about domestic and international regulations.

Recent Progress of the DUPIC Fuel Fabrication in Korea

  • Lee, J.W.;Kim, W.K.;Lee, Jae-W.;Park, G.I.;YANG, M.S.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.170-181
    • /
    • 2004
  • DUPIC powder and pellets were successfully fabricated in accordance with the quality assurance program described in the Quality Assurance Manual for DUPIC fuel fabrication, which was developed on the basis of the CAN3-Z299.2-85 standard. This manual describes the quality management system applicable to the activities performed for DUPIC fuel fabrication. It covers the work processes, policies and procedures used for planning, executing, and verifying the work carried out for DUPIC fuel fabrication. It is important that a Quality Program is in place before the fabrication of the fuel for irradiation testing. In order to qualify the DUPIC pellet manufacturing processes, 3 series of experiments for the pre-qualification and 3 series for the qualification were performed. In these experiments, the optimum process conditions were established. Then, under the control of the QA program, 8 series of production runs were performed to make the qualified DUPIC pellets in a batch size of 1 kg. In these production runs, DUPIC fuel pellets satisfying the standard CANDU fuel pellet specifications could be successfully produced.

  • PDF

표준관입 시험 해머의 에너지비와 동적효율 (Ratio of Hammer Energy and Dynamic Efficiency of Standard Penetration Test)

  • 이창호;이우진
    • 한국지반공학회논문집
    • /
    • 제21권9호
    • /
    • pp.5-12
    • /
    • 2005
  • 해머에 의해 발생한 에너지와 그의 전달은 표준관입시험의 N치에 영향을 주며 이러한 SPT해머에너지는 이론적 에너지, 속도 에너지, 롯드 에너지, 그리고 동적효율 등으로 나누어진다. 본 연구에서는 항타 분석기(Pile Driving Analyzer, PDA)와 디지털 라인-스캔카메라(Digital Line-Scan Camera)를 이용하여 국내에서 널리 사용 중인 시험 장비들에 대해 롯드 에너지와 속도에너지를 직접 측정하여 각 시험 장비의 동적효율(Dynamic efficiency)을 계산하였다. 시험 결과 FV 방법에 의해 산정된 각 장비의 평균 롯드 에너지 전달율은 도넛해머, 안전해머, 자동해머의 경우 각각 49.57, 61.60, $87.04\%$로 측정되었다. 해머의 타격직전의 박하 속도는 도넛해머, 안전해머, 자동해머의 경우 각각 $3.177{\pm}0.872$, $3.385{\pm}0.681$, $3.651{\pm}0.550$ m/s로 측정되었고 이에 따라 동적 효율은 각각 0.732, 0.801, 0.973으로 계산되었다.

Rod effects on transferred energy into SPT sampler using smart measurement system

  • Park, Geunwoo;Kim, Namsun;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.159-172
    • /
    • 2022
  • To improve the accuracy of the standard penetration test (SPT) results, smart measurement system, which considers the energy transfer ratio into the sampler (ETRSampler), is required. The objective of this study is to evaluate the effects of joints and rod length on the transferred energy into the sampler. The energy transfer ratios into the rod head (ETRHead) and ETRSampler, and the energy ratio from the head to the sampler (ERHS) were obtained using energy modules, which were installed at the rod head and above the SPT sampler. Linear regression analyses are conducted to correlate the ERHS with the number of joints, rod length, and SPT N-values. In addition, the dynamic resistances are calculated using both transferred energies into the rod head and into the sampler, and are compared with the corrected cone tip resistance measured from the cone penetration test (CPT). While the ETRHead are generally constant, but the ETRSampler and ERHS gradually decrease along the depth or the number of joints, except at certain depths with high SPT N-values. Thus, the ERHS can be estimated using the number of joints, rod length, and SPT N-values. The dynamic resistance evaluated by ESampler produces a better correlation with the corrected cone tip resistance than that by EHead. This study suggests that transferred energy into the SPT sampler may be effectively used for more accurate subsurface characterization.