• 제목/요약/키워드: Energy Savings

검색결과 574건 처리시간 0.031초

영구자석형 동기 전동기를 이용한 Compact Gearless 엘리베이터 시스템 (Compact Gearless Elevator System Using PMSM)

  • 안준선;김일종;배승형;강석주;이제필
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.1-3
    • /
    • 1999
  • The implementation of the compact gearless elevator system with Permanent Magnet Synchronous Motor is presented. For the purpose of the voltage suppression in the motor input side, the LRC filter is used. The automatic encoder alignment algorithm with rotor pole position is developed, and it is available in the full range of the load. The implemented system makes 11% energy savings comparing the system with the induction motor.

  • PDF

에너지절약을 위한 조도기준 설정에 관한 연구 (A Study on the Establishment of Stnadard Illumination Levels for Energy Savings)

  • 김수길;이진우;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.11-16
    • /
    • 1993
  • 쾌적한 환경을 제공하기 위한 조명은 보건 위생 및 작업 능률 등에 커다란 영향을 미친다. 그러나 적절하지 못한 조명은 전술한 내용을 약화시키며 에너지 낭비를 초래하게 된다. 그러므로 적절한 조도기준이 필요하다. 본 연구에서는 세계각국의 조도기준 자료를 수집 분석하고 우리나라 사람을 대상으로 한 실험결과를 적용하여 우리나라에 적합한 조도기준을 설정하였다. 본 연구의 결과는 조도설계 및 관리의 효율화 및 작업능률의 극대화를 이룰수 있으며, 조명 에너지 관리의 효율화를 통한 에너지 절감의 효과를 얻을 것이라 기대된다.

  • PDF

Robust Polymeric Membranes for the Separation of Petrochemicals using Pervaporation

  • Nam, Sang-Yong
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.51-54
    • /
    • 2004
  • Utilization of membranes offers the promise of extraordinary energy savings if successfully applied to hydrocarbon-hydrocarbon and other organic separations. Membranes are bound to enter into refining and petrochemical operations involving liquid separations once appropriate materials and modules are developed. Hybrid processes such as utilizing membrane modules to break azeotropes formed during distillation are particularly attractive because they offer less process complexity and reduced capital investment[1,2].(omitted)

  • PDF

Developing an Integrated Evaluation Technology for Energy- and Cost-Efficient Building Design Based on BIM in the Real-time Manner

  • Park, Jae Wan;Lee, Yun Gil
    • Architectural research
    • /
    • 제16권3호
    • /
    • pp.93-100
    • /
    • 2014
  • Existing BIM(Building Information Modeling) based energy evaluation tools cannot be utilized enough for the potential performance of BIM because most of them have not provided the integrated model for energy evaluation, assessment of the material, cost of the construction, and so on. This research aims to propose and develop a new application, EcoBIM, to support an integrated evaluation of the energy and cost efficiencies of the design alternatives within the design process. The proposed application functions as a BIM-based evaluation system that calculates energy-savings performance as well as the construction cost of the alternatives at the design stage. This study mainly focuses on the possibilities of developing the proposed technology. We also suggest an advanced design process using the proposed system, corresponding to changes of national regulations in Korea. This study deduce that EcoBIM can allow architects to make suitable decisions regarding energy- and cost-efficient designs. The proposed design process will allow architects not only to check the eco-friendly performance of design alternatives but also predict the operation cost in a certain period in the future. EcoBIM can prevent large-scale design changes required to obtain environmental certification and enable the owner to make an informed decision about the initial investment of construction according to the result of the analysis of the energy requirement at the design stage.

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석 (Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window)

  • 이장만;조수;임상훈;송규동
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

Biologically Inspired Node Scheduling Control for Wireless Sensor Networks

  • Byun, Heejung;Son, Sugook;Yang, Soomi
    • Journal of Communications and Networks
    • /
    • 제17권5호
    • /
    • pp.506-516
    • /
    • 2015
  • Wireless sensor networks (WSNs) are generally comprised of densely deployed sensor nodes, which results in highly redundant sensor data transmissions and energy waste. Since the sensor nodes depend on batteries for energy, previous studies have focused on designing energy-efficient medium access control (MAC) protocols to extend the network lifetime. However, the energy-efficient protocols induce an extra end-to-end delay, and therefore recent increase in focus on WSNs has led to timely and reliable communication protocols for mission-critical applications. In this paper, we propose an energy efficient and delay guaranteeing node scheduling scheme inspired by biological systems, which have gained considerable attention as a computing and problem solving technique.With the identification of analogies between cellular signaling systems and WSN systems, we formulate a new mathematical model that considers the networking challenges of WSNs. The proposed bio-inspired algorithm determines the state of the sensor node, as required by each application and as determined by the local environmental conditions and the states of the adjacent nodes. A control analysis shows that the proposed bio-inspired scheme guarantees the system stability by controlling the parameters of each node. Simulation results also indicate that the proposed scheme provides significant energy savings, as well as reliable delay guarantees by controlling the states of the sensor nodes.

장주기 대용량 전력저장장치의 부하이전에 대한 실계통 적용 경제성 평가 연구 (An Economic Assessment of Large-scale Battery Energy Storage Systems in the Energy-Shift Application to Korea Power System)

  • 박종배;박용기;노재형;장병훈;윤용범
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.384-392
    • /
    • 2015
  • This paper presents an economic assessment of large-scale Li-ion battery energy storage systems applied to Korean power system. There are many applications of the battery energy storage systems (BESSs) and they can provide various benefits to power systems. We consider BESSs to the energy time-shift application to Korean power system and evaluate the benefits from the application of BESS in the social perspective. The mixed integer programming (MIP) algorithm is used to resolve the optimal operation schedule of the BESS. The social benefits can include the savings of the fuel cost from generating units, deferral effects of the generation capacity, delay of transmission and distribution infra construction, and incremental CO2 emission cost impacts, etc. The economic evaluation of the BESS is separately applied into Korean power systems of the Main-land and Jeju island to reflect the differences of the load and generation patterns.

Energy-saving Strategy Based on an Immunization Algorithm for Network Traffic

  • Zhao, Dongyan;Long, Keping;Wang, Dongxue;Zheng, Yichuan;Tu, Jiajing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권4호
    • /
    • pp.1392-1403
    • /
    • 2015
  • The rapid development of both communication traffic and increasing optical network sizes has increased energy consumption. Traditional algorithms and strategies don't apply to controlling the expanded network. Immunization algorithms originated from the complex system theory are feasible for large-scale systems based on a scale-free network model. This paper proposes the immunization strategy for complex systems which includes random and targeted immunizations to solve energy consumption issues and uses traffic to judge the energy savings from the node immunization. The simulation results verify the effectiveness of the proposed strategy. Furthermore, this paper provides a possibility for saving energy with optical transmission networks.

An Evaluation of Energy Saving Measures for Ocean Going Vessels

  • Kim, Yong-Wong;Kang, Dal-Won;Nam, Ki-Chan;Nam, Hyung-Sik
    • 한국항해항만학회지
    • /
    • 제39권2호
    • /
    • pp.107-113
    • /
    • 2015
  • This paper analyzes and evaluates the importance of energy saving measures based on qualitative survey. Through literature review and group interviews with specialists, 4 factors, 13 measures for energy savings, and 4 evaluation criteria were selected to carry out an Analytic Hierarchy Process (AHP) analysis. At the first stage of AHP analysis, the importance of factors was derived, and then the importance of 13 measures. Lastly, the cross examination of 4 factors was carried out in order to evaluate the best possible qualitative considerations. The result revealed that 'choosing the best course weather', is the most important factor with the highest value on applicability and operational complexity criteria. These results may imply that operational considerations are regarded as a main factor to be taken into account when considering appropriate energy saving measures.

중앙 냉방시스템에 대한 외기보상제어의 절약 성능에 관한 실험적 연구 (Experimental Study on Energy Saving Performance of Outdoor Temperature Reset Control Strategy for Central Cooling System)

  • 김동철;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.30-36
    • /
    • 2011
  • In this study, energy saving performance of outdoor temperature reset control strategy for central cooling system is researched by experiments. Outdoor temperature reset control is the control method to change indoor air set temperature according to outdoor air temperature change. The range of indoor air set temperature is represented by the comfort temperature range of indoor air temperature offered from ASHRAE and indoor air set temperature is programmed between $22^{\circ}C$ and $27^{\circ}C$ by outdoor air temperature $20^{\circ}C{\sim}32^{\circ}C$ in summer. As a result of applying outdoor temperature reset control to central cooling system, the suggested control method shows better performances of energy savings than the conventional method which indoor temperature maintains constantly.