• Title/Summary/Keyword: Energy Savings

Search Result 574, Processing Time 0.025 seconds

A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building (사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구)

  • Son, Chang-Hee;Yang, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

Heuristic Algorithms for Optimization of Energy Consumption in Wireless Access Networks

  • Lorincz, Josip;Capone, Antonio;Begusic, Dinko
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.4
    • /
    • pp.626-648
    • /
    • 2011
  • Energy consumption of wireless access networks is in permanent increase, which necessitates development of more energy-efficient network management approaches. Such management schemes must result with adaptation of network energy consumption in accordance with daily variations in user activity. In this paper, we consider possible energy savings of wireless local area networks (WLANs) through development of a few integer linear programming (ILP) models. Effectiveness of ILP models providing energy-efficient management of network resources have been tested on several WLAN instances of different sizes. To cope with the problem of high computational time characteristic for some ILP models, we further develop several heuristic algorithms that are based on greedy methods and local search. Although heuristics obtains somewhat higher results of energy consumption in comparison with the ones of corresponding ILP models, heuristic algorithms ensures minimization of network energy consumption in an amount of time that is acceptable for practical implementations. This confirms that network management algorithms will play a significant role in practical realization of future energy-efficient network management systems.

A Study on the Evaluation of Energy Performance According to Greenery Cover in Education Buildings (학교건물에서의 외피녹화에 따른 에너지성능 평가에 관한 연구)

  • Seok, Ho-Tae;Yang, Jeong-Hoon;Jung, Jae-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.40-47
    • /
    • 2008
  • The importance for energy consumptions has being emphasized because of problems of the energy and environment. Especially, education buildings among public buildings which have being emphasized the application of environment-friendly elements because of large energy consumptions. Accordingly, this study established parameters of green walls and green roofs which have ecological effects and energy savings. And then this study analyzed indoor thermal environments and energy consumptions due to green walls and green roofs through the energy simulation(Visual DOE 4.0) and the actual measurement.

Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence - (생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.911-919
    • /
    • 2003
  • When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

LCC Analysis of Residential Dehumidifying Air Conditioning System using Thin Separation Membrane (분리막을 이용한 주거용 제습공조시스템의 LCC 분석)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • The climate of summer in Korea is quite hot and humid. Many studies have been carried out to reduce the energy required for operating a dehumidifier. The dehumidifier is mainly connected to the cooling system since it operates in the summer. Conventional dehumidification methods often require additional cooling and energy for dehumidification. In this study, a system for increasing the efficiency by applying a membrane was analyzed. Its energy saving effect was analyzed when it was applied to residential buildings. Economic efficiency was also evaluated. As a result of this study, 9.0% energy savings were achieved for residential buildings. The investment recovery period was 28.9 years. Such long investment recovery period was because the initial investment cost was excessive and annual energy saving only appeared in the summer.

A Study on the Energy Saving Hydraulic Control System using Variable Displacement Hydraulic Pump/Motor (가변 유압 펌프/모터를 이용한 유압 제어 시스템의 에너지 절감에 관한 연구)

  • 조용래;안경관
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.100-108
    • /
    • 2003
  • This paper proposes a flywheel hybrid vehicle to solve the energy crisis problem by the exhaustion of a fossil fuel and air pollution for the conservation of environment. The proposed flywheel hybrid vehicle is composed of an accumulator and a flywheel as the energy generation and storage component and three variable displacement hydraulic pump/motors as the energy transfer devices. Flywheel has the characteristics of high energy density and easy energy absorption and consumption. The effectiveness of the energy-saving of the proposed flywheel hybrid vehicle is verified by simulation using Matlab/simulink. First of ail, analytical modeling for the flywheel hybrid vehicle is presented and simulations are performed based on the experimental efficiency data of a variable displacement pump/motor. The results of the simulation show that the effect of energy savings is realized by the proposed hybrid vehicle in 3 different city driving patterns.

Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal (오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.

Heating and Cooling Performance of a Ground Coupled Heat Pump System with Energy-Slab (에너지슬래브 적용 지열원 열펌프 시스템의 성능 특성에 관한 실증 연구)

  • Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.196-203
    • /
    • 2012
  • Energy foundations and other thermo-active ground structure, energy wells, energy-slab, and pavement heating and cooling represent an innovative technology that contributes to environmental protection and provides substantial long-term cost savings and minimized maintenance. This paper focuses on earth-contact concrete elements that are already required for structural reasons, but which simultaneously work as heat exchangers. Pipes, energy slabs, filled with a heat carrier fluid are installed under conventional structural elements, forming the primary circuit of a geothermal energy system. The natural ground temperature is used as a heat source in winter and a heat sink in summer. The geothermal heat pump system with energy-slab represented very high heating and cooling performance due to the stability of EWT from energy slab. However, the performance of it seemed to be affected by the atmospheric air temperature.

A Study for Predicting Building Energy Use with Regression Analysis (회귀분석에 의한 건물에너지 사용량 예측기법에 관한 연구)

  • 이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1090-1097
    • /
    • 2000
  • Predicting building energy use can be useful to evaluate its energy performance. This study proposed empirical approach for predicting building energy use with regression analysis. For the empirical analysis, simple regression models were developed based on the historical energy consumption data as a function of daily outside temperature, the predicting equations were derived for different operational modes and day types, then the equations were applied for predicting energy use in a building. BY selecting a real building as a case study, the feasibilities of the empirical approach for predicting building energy use were examined. The results showed that empirical approach with regression analysis was fairly reliable by demonstrating prediction accuracy of $pm10%$ compared with the actual energy consumption data. It was also verified that the prediction by regression models could be simple and fairly accurate. Thus, it is anticipated that the empirical approach will be useful and reliable tool for many purposes: retrofit savings analysis by estimating energy usage in an existing building or the diagnosis of the building operational problems with real time analysis.

  • PDF