Browse > Article
http://dx.doi.org/10.6110/KJACR.2012.24.2.196

Heating and Cooling Performance of a Ground Coupled Heat Pump System with Energy-Slab  

Choi, Jong-Min (Department of Mechanical Engineering, Hanbat National University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.24, no.2, 2012 , pp. 196-203 More about this Journal
Abstract
Energy foundations and other thermo-active ground structure, energy wells, energy-slab, and pavement heating and cooling represent an innovative technology that contributes to environmental protection and provides substantial long-term cost savings and minimized maintenance. This paper focuses on earth-contact concrete elements that are already required for structural reasons, but which simultaneously work as heat exchangers. Pipes, energy slabs, filled with a heat carrier fluid are installed under conventional structural elements, forming the primary circuit of a geothermal energy system. The natural ground temperature is used as a heat source in winter and a heat sink in summer. The geothermal heat pump system with energy-slab represented very high heating and cooling performance due to the stability of EWT from energy slab. However, the performance of it seemed to be affected by the atmospheric air temperature.
Keywords
GCHP; Energy-slab; GLHX; COP; Building structure;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yu, H. K., 2008, Development and performance evaluation of ground heat exchanger utilizing PHC pile foundation of building, Journal of the Korean Solar Energy Society, Vol. 5, pp. 56-64.   과학기술학회마을
2 NexGeo Co., 2010, Aquifer thermal energy storage heating and cooling systems development, Final Report of Ministry of Knowledge Economy, 2007-N-GE01-P-01-0-000.
3 Geo-Tech Co., 2006, Research of two-well type ground water heat pump system, Final Report of Ministry of Knowledge Economy, 2004-NGE11- P-02.
4 www.enercret.com.
5 Ministry of Knowledge Economy, 2009, Standards of support, installation, and management for new and renewable energy system, Ministry of Knowledge Enconmy Announcement, 2009-332.
6 KEMCO, 2010, New and renewable energy statistics 2010, Report of Korea Energy Management Corporation, KEMCO, Yongin, Korea.
7 Gao, Q., Li, M., Yu, M., Spitler, J. D., and Yan, Y. Y., 2009, Review of development from GSHP to UTES in China and other countries, Renewable and Sustainable Energy Reviews, Vol. 13, No. 6, pp. 1383-1394.   DOI
8 Lee, J. Y., 2009, Current status of ground source heat pumps in Korea, Renewable and Sustainable Energy Reviews, Vol. 13, No. 6/7, pp. 1560-1568.   DOI
9 Paksoy, H. O., Gürbüz, Z., Turgut, B., Dikici, D., and Evliya, H., 2004, Aquifer thermal storage( ATES) for air-conditioning of a supermarket in Turkey, Renewable Energy, Vol. 29, pp. 1991-1996.   DOI   ScienceOn
10 Tarnawski, V. R., Leong, W. H., Momose, T., and Hamada, Y., 2009, Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan, Renewable Energy, Vol. 34, pp. 127-134.   DOI   ScienceOn