• Title/Summary/Keyword: Energy Saving Device

Search Result 199, Processing Time 0.025 seconds

An Offloading Decision Scheme Considering the Scheduling Latency of the Cloud in Real-time Applications (실시간 응용에서 클라우드의 스케줄링 지연 시간을 고려한 오프로딩 결정 기법)

  • Min, Hong;Jung, Jinman;Kim, Bongjae;Heo, Junyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.6
    • /
    • pp.392-396
    • /
    • 2017
  • Although mobile device-related technologies have developed rapidly, many problems arising from resource constraints have not been solved. Computation offloading that uses resources of cloud servers over the Internet was proposed to overcome physical limitations, and many studies have been conducted in terms of energy saving. However, completing tasks within their deadlines is more important than saving energy in real-time applications. In this paper, we proposed an offloading decision scheme considering the scheduling latency in the cloud to support real-time applications. The proposed scheme can improve the reliability of real-time tasks by comparing the estimated laxity of offloading a task with the estimated laxity of executing a task in a mobile device and selecting a more effective way to satisfy the task's deadline.

Implementation and application of remote control system using LACC(Local Area Control Center) (LACC를 이용한 원격제어 시스템 구현 및 적용)

  • Park Tae-Jin;Jang Myung-Kee;Chung Seung-Ryul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.15-22
    • /
    • 2006
  • Nowadays, there is called energy saving, that it is accomplished with a lot study and application development as according to demand of all around world. It is using to network device of wire or wireless such as internet, lan, plc, and zigbee and that we should be accomplished to study about method that spending a little cost to fatal error in control system that be expected of frequent occurrence on network, and that have method to do construction a little bit tried out. Also, in that such a embedded system with network function case, there is important thing that it is remote management to network node and control methods to trust because firmware upgrade have the advantage of more than the other device. In this paper, we have verified through a result of experiment for efficient remote management and control method as previously stated in this paper, that it is area of the PLC for sensor node and doing management to relay, and implementation of the LACC which is core part of the ESS, and in order to get a result to trust from doing analysis of capacity and test.

The research of Automatic Classification of Products Using Smart Plug by Artificial Intelligence Technique (인공지능 기법으로 스마트 플러그를 이용한 제품 자동분류에 관한 연구)

  • Son, Chang-Woo;Lee, Sang-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.842-848
    • /
    • 2018
  • The Smart plug is a device that connects between the outlet and the product at home, and it is an IoT type device that can drive energy saving and transmit information to the outside by power on / off control function and power measurement function. In this case, a smart plug that incorporates deep learning of intelligence technology that allows people to learn how to think about a computer, automatically classifies a product as it operates, and automatically tests the operating status of the washing machine by using input AC current pattern. Through this study, even if the product does not function as IoT, it can classify product type and operation state by smart plug connection alone, so we can draw a new paradigm of life pattern and energy saving in one family.

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.

Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane (분리막 제습공조시스템의 잠열부하 저감효과 예측)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.

Dynamic Power Management For Energy Efficient Wi-Fi Direct (에너지 효율적인 Wi-Fi Direct를 위한 동적 전력 관리 기법)

  • Seo, Youn;Ko, Young-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.8
    • /
    • pp.663-671
    • /
    • 2013
  • Recently, the Wi-Fi Direct standard based on WLAN is getting more attention as a new technology for enabling D2D(Devide-to-Device) communications on mobile devices. However, due to limited power resource of mobile devices and, an energy inefficiency problem can be an issue. In order to solve this problem, the Wi-Fi Direct defines two power management schemes: Opportunistic scheme and Notice of Absence(NoA) scheme. However, there is no concrete description of which power management scheme would be better for when. In this paper, via comprehensive simulation studies using ns-3, we show that each scheme presents obviously different performance and energy efficiency according to data traffic patterns. We then propose more energy efficient way of dynamically switching the two power management schemes.

Hierarchical Power Management Architecture and Optimal Local Control Policy for Energy Efficient Networks

  • Wei, Yifei;Wang, Xiaojun;Fialho, Leonardo;Bruschi, Roberto;Ormond, Olga;Collier, Martin
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.540-550
    • /
    • 2016
  • Since energy efficiency has become a significant concern for network infrastructure, next-generation network devices are expected to have embedded advanced power management capabilities. However, how to effectively exploit the green capabilities is still a big challenge, especially given the high heterogeneity of devices and their internal architectures. In this paper, we introduce a hierarchical power management architecture (HPMA) which represents physical components whose power can be monitored and controlled at various levels of a device as entities. We use energy aware state (EAS) as the power management setting mode of each device entity. The power policy controller is capable of getting information on how many EASes of the entity are manageable inside a device, and setting a certain EAS configuration for the entity. We propose the optimal local control policy which aims to minimize the router power consumption while meeting the performance constraints. A first-order Markov chain is used to model the statistical features of the network traffic load. The dynamic EAS configuration problem is formulated as a Markov decision process and solved using a dynamic programming algorithm. In addition, we demonstrate a reference implementation of the HPMA and EAS concept in a NetFPGA frequency scaled router which has the ability of toggling among five operating frequency options and/or turning off unused Ethernet ports.

A Study on Performance Evaluation of On-board Electric Device of TTX(Tilting Train Express) (틸팅열차(TTX)의 정장품 성능평가 연구)

  • Han, Seong-Ho;Lee, Su-Gil;Seo, Sung-Il
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.239-242
    • /
    • 2005
  • This paper introduced an approach of improvement of performance of Electric device for EMU type Train like as TTX. The electric equipments are characterized by insulation, Noise, cooling system etc. and Their weight arc decided by these factors. There are two kinds of power source in EMU train. First, DC voltage source, 1500 volt, 750 volt is used for subway system. Second, AC power source 25000 volt is applied to high speed train and existing main lines. Composite material has the protection of inrush current and high frequency noise. We can use this material to minimize weight of train. Additionally we can get energy saving when operator service TTX.

  • PDF

A Method for $\frac{dv}{dt}$ suppression during switching of inverter (인버터 스위칭시 $\frac{dv}{dt}$ 억제 방법)

  • Suh, Duk-Bae;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.156-158
    • /
    • 1994
  • In recent days, the various adjustable speed drives are widely employed at the industrial applications for the purpose of energy saving and speed control. In particular, for the machine control applications. the switching frequency is required to be increased for better dynamic performance of the drive. Moreover, this also leads to the reduction of the switching loss of the device. For IGBT (Insulated Gate Bipolar Transistor), the most widely used switching device in the inverters below the 100[kW] range, the falling and falling time is of the order about $200{\sim}300[ns]$. Therefore unexpected phenomena occurs such as voltage spikes due to high gradient of current at the switching instant, the weakening of motor insulation due to high gradient of voltage. In this paper, a new voltage gradient suppression technique is presented in both theoretically and experimentally.

  • PDF

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.