• 제목/요약/키워드: Energy Save

검색결과 804건 처리시간 0.028초

화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션 (A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant)

  • 한규일
    • 수산해양기술연구
    • /
    • 제50권1호
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

전문가 설문조사를 통한 에너지 효율적인 병원시설을 위한 중요한 영향요소의 분석 (An Analysis of Important Factors for Energy Efficient Healthcare Facilities on Experts' Survey)

  • 최여진;최율
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: There have been more researches focused on eco-friendly construction practices in order to save energy consumed and these practices have been extensively applied for constructing buildings. However, researches on energy consumption saving and efficiency for hospital facilities have been still insufficient. This research aims to draw factors that affect energy efficiency of hospital buildings through literature reviews and perform an expert-survey using AHP(Analytical Hierarchy Process) method in order to analyze the importances and priorities of these energy efficient factors. Method: Using the AHP method, this paper suggests the importances and priorities of factors to affect energy efficiency in hospital buildings. The survey of experts at a architectural design and a construction management companies was conducted via e-mail and mail. Result: As a result, factors of window and door, insulation, ventilation, and natural lighting turned out relatively important as respectively 0.104, 0.102, 0.101, and 0.095 n the energy efficiency in hospital buildings, while factors of artificial lighting, geothermal, solar heat, and control did unimportant as 0.027, 0.033, 0.043, and 0.053.

Energy-Aware Virtual Data Center Embedding

  • Ma, Xiao;Zhang, Zhongbao;Su, Sen
    • Journal of Information Processing Systems
    • /
    • 제16권2호
    • /
    • pp.460-477
    • /
    • 2020
  • As one of the most significant challenges in the virtual data center, the virtual data center embedding has attracted extensive attention from researchers. The existing research works mainly focus on how to design algorithms to increase operating revenue. However, they ignore the energy consumption issue of the physical data center in virtual data center embedding. In this paper, we focus on studying the energy-aware virtual data center embedding problem. Specifically, we first propose an energy consumption model. It includes the energy consumption models of the virtual machine node and the virtual switch node, aiming to quantitatively measure the energy consumption in virtual data center embedding. Based on such a model, we propose two algorithms regarding virtual data center embedding: one is heuristic, and the other is based on particle swarm optimization. The second algorithm provides a better solution to virtual data center embedding by leveraging the evolution process of particle swarm optimization. Finally, experiment results show that our proposed algorithms can effectively save energy while guaranteeing the embedding success rate.

VAV 터미널 박스의 최소풍량 제어방식 비교 연구 (A Study on the Comparison Analysis of Minimum Airflow Control Logic of VAV Terminal Box)

  • 조영흠;강수현;성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.96-102
    • /
    • 2012
  • The minimum airflow of VAV terminal boxes is a key factor for comfort, indoor air quality(IAQ) and energy cost. If the minimum airflow is not reasonable, it would waste energy and make IAQ problems. There are two types of VAV terminal box control logic. One is the single maximum, another is the dual maximum control logic. Dual maximum control logic is more efficiency way to reduce the energy consumption. It has a minimum airflow set point and a heating maximum set point. It allows the minimum airflow set point to be much lower than single maximum control logic. A building simulation was conducted to evaluate the energy consumption and the IAQ according to the control logic of the V AV terminal box. In the simulation, dual maximum control logic can save the energy up to 6.5% compared to the single maximum control logic.

열교환기를 사용한 냉각/재가열 장치의 에너지 절감에 관한 연구 (A Study on the Energy Saving of Cooling/Reheating System Using Heat Exchanger)

  • 김진혁;유성연;최양규
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.482-491
    • /
    • 2010
  • In conventional air-handling units, when the circulated air from the air-conditioned space pass through the cooling coil, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to estimate the thermal performance and energy saving of the cooling/reheating system using heat exchanger which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. The energy balance equations to estimate the state of the air for each components were provided and the heat transfer rates and the energy saving rates for the system were calculated from the equations. The results showed that the energy saving was up to 40% under present conditions, and saving rates were significantly affected by the air velocity, inlet conditions and the effectiveness of heat exchanger.

IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구 (PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method)

  • 박진우;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

국내 종합병원의 에너지 사용량에 영향을 미치는 요인 도출 (Study on the elements affecting energy consumption of general hospitals in Korea)

  • 정다운;김선숙;김혜기;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.63-71
    • /
    • 2020
  • Purpose : The purpose of this study is to analyze the elements that affect the energy consumption of general hospitals in Korea. Methods : Factors affecting energy consumption in general hospitals include facility elements and operating elements. The effects of these elements on energy consumption of general hospitals were analyzed by statistical methods such as t-test, anova, correlation analysis, and regression analysis. Results : Total floor area, number of operating rooms, number of MRI, number of staffs, and number of outpatients can be said as useful variables that can explain energy consumption in general hospitals. Implication : It is possible to save energy consumption in general hospitals by adjusting major variables that affect the energy consumption of general hospitals.

빌딩 에너지 관리 최적화 알고리즘 설계 및 구현 (Design and Implementation of Optimal Control Algorithms for Building Energy Management)

  • 진중화;정선태
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Energy-efficient Low-delay TDMA Scheduling Algorithm for Industrial Wireless Mesh Networks

  • Zuo, Yun;Ling, Zhihao;Liu, Luming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권10호
    • /
    • pp.2509-2528
    • /
    • 2012
  • Time division multiple access (TDMA) is a widely used media access control (MAC) technique that can provide collision-free and reliable communications, save energy and bound the delay of packets. In TDMA, energy saving is usually achieved by switching the nodes' radio off when such nodes are not engaged. However, the frequent switching of the radio's state not only wastes energy, but also increases end-to-end delay. To achieve high energy efficiency and low delay, as well as to further minimize the number of time slots, a multi-objective TDMA scheduling problem for industrial wireless mesh networks is presented. A hybrid algorithm that combines genetic algorithm (GA) and simulated annealing (SA) algorithm is then proposed to solve the TDMA scheduling problem effectively. A number of critical techniques are also adopted to reduce energy consumption and to shorten end-to-end delay further. Simulation results with different kinds of networks demonstrate that the proposed algorithm outperforms traditional scheduling algorithms in terms of addressing the problems of energy consumption and end-to-end delay, thus satisfying the demands of industrial wireless mesh networks.

열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 - (Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF