• Title/Summary/Keyword: Energy Reduction Design

Search Result 798, Processing Time 0.027 seconds

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Study on PCM Applied Thermal Storage Wall System to Reduce Cooling Energy (냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구)

  • Lee, Kyuyoung;Ryu, Ri;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.247-256
    • /
    • 2014
  • The regulations to reduce energy consumption and carbon dioxide emission in building sectors are being developed and promoted all over the world. However, in Korea, as balcony extension of the apartments has been legally allowed, it became prevalent and resulted in excessive energy consumption. This study derived the possibility of PCM application to the thermal storage wall system through theoretical consideration and investigated the problems occurring when the balcony space has been extended to the diverted space. In addition, this study aims at the possibility of verifying the installation and confirming the cooling energy reduction effect, by conducting measuring tests with the actual installation of PCM applied thermal storage wall system. As a result of theoretical consideration, it is determined that the disadvantages with the existing thermal storage wall system can be complemented by applying PCM, and this study suggests the PCM applied Thermal Storage Wall System. The study was conducted on 1/6 of a miniature inner room of a domestic apartment with 84 $m^2$ of exclusive area. From the results of actual measurements, it is confirmed that the balcony extension structure can gain 11.3% of more calories than the existing balcony structure, resulting in the increase in cooling energy usage. It is determined that the installation of the PCM applied Thermal Storage Wall System may gain 25.2% of less calories to reduce cooling energy usage.

Study on Improvement Measures of Green Standard for Energy and Environmental Design for Expansion of Applying Green Roof - Focused on LEED in the USA and BREEAM in the UK - (옥상녹화 적용확대를 위한 녹색건축인증제도 개선방안 연구 - 미국 LEED 및 영국 BREEAM의 비교·분석을 중심으로 -)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Lee, Bum-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2018
  • Green roof in Korea has been recognized as part of landscape area and local governments enacted municipal ordinance for supporting green roof thereby assisting part of expenses spent for green roof within a range of budget for buildings which are eligible for the green roof support of existing buildings. However, it is necessary to enforce a regulation of mandatory green roof for new buildings in order to expand green roof application and provide a variety of assistances such as subsidy payment, tax relief, and mitigation of floor area ratio-related regulation as done in other advanced nations. In particular, LEED(Leadership in Environmental and Energy Design) in the USA applies additional point directly for green roof in terms of the reduction in heat island effects. For example, the following items are beneficial to have additional points: habitat preservation or restoration, external space, rainwater management, reduction in outdoor water usage, minimum energy performance, and optimum energy performance. In addition, the BREEAM(Building Research Establishment Environmental Assessment Method) in the UK specifies green roof as one of assessment items to be complied in terms of diversity of species. As such, LEED and BREEAM reflect direct and indirect effects of green roof on assessment criteria, which suggest a direction to green building certification criteria in Korea where only additional points are given for green roof according to soil depth.

Radiation Power Control by Means of Absorptive Material Arrangement in an Enclosure (흡음재 배치를 통한 닫힌 공간에서의 소음원 방사 파워 제어)

  • 조성호;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.688-691
    • /
    • 2004
  • We have studied the possibility of global noise reduction by the sound power control through selection of distribution and impedance of absorptive materials. It is necessary to investigate the relation between the global sound energy in the field and the total sound power radiated by sources. In the previous work (1,2), the authors presented a useful design method to change boundary condition that can be useful to reduce noise in acoustically small enclosures. The possibility of total acoustic potential energy reduction by acoustic source power control is examined in an acoustically small cavity. Using acoustic energy balance equation, the relation between global noise control performance and absorptive material's arrangement/impedance is deduced. Numerical simulation is performed to interpret its physical meaning in terms of absorbent's distribution and impedance.

  • PDF

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

Development of a Method to Estimate the Seasonal Heating Load for Plastic Greenhouses (플라스틱 온실의 기간난방부하 산정 방법 개발)

  • Nam, Sang Woon;Shin, Hyun Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.37-42
    • /
    • 2015
  • In order to provide fundamental data for the creation of environmental design criteria for horticultural facilities, we developed a method to easily calculate the seasonal heating load applying heating degree-hour while taking into account heating load reductions due to solar radiation in the daytime, and reviewed through greenhouse heating experiments. Heating experiments and measuring meteorological environments were carried out in three greenhouses located at Buyeo, Cheonan, and Buan, and we derived reduction factors of seasonal heating load according to hours of sunshine. Daily mean hours of sunshine during the experiment period in each of the greenhouse was 4.0 to 8.3 hours, and the reduction factor of seasonal heating load was 0.64 to 0.85, has been shown to decrease linearly with the increase in hours of sunshine. A method to estimate the seasonal heating load for greenhouses was developed using the reduction factor of seasonal heating load derived from the greenhouse heating experiment, including the adjustment factor of seasonal heating load according to hours of sunshine. The developed method was validated through heating experiments in a greenhouse located at Cheonan. Greenhouse seasonal heating loads calculated by the method developed in this study were analyzed to show the estimate error of 1.2 to 5.0%. It showed that the accuracy increased 2.3 times more than when using the heating load reduction factor of 0.75 applied uniformly in previous studies. Thus, the calculation method of seasonal heating load for greenhouses considering hours of sunshine developed in this study could be utilized for energy estimation, management planning, and economic evaluation in greenhouse design.

A Study on Shape Design of Motorcycle Disk using Thermal and Stress Analysis (모터싸이클 디스크 브레이크의 열 및 응력 해석을 통한 형상 설계)

  • 강석현;박시형;이성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.363-368
    • /
    • 2001
  • Studies on brake system recently are focused on braking performance, especially the consideration on safety of braking system in an extreme situation and reduction of vibration and noise during braking operation. The thermal crack and Judder from the friction between brake disc and pad can bring the threaten of passengers' safety in the end. Braking force comes from the change of kinetic energy to friction energy. Since heat energy is developed from here, the analysis on thermal stress and thermal strain can be the good data when selecting the material of brake pad and designing heat radiation holes on the disc and it will also be the data when designing the thickness of the disc. This paper is intended to show a creative design method by suggesting the thermal analysis data through FEM study and using shape design parameters.

  • PDF

Study about the Design of Special Blade and Simulation for Wind Generation system (풍력발전 시스템의 특수 블레이드 설계 및 시뮬레이션에 관한 연구)

  • Yoon, Jeong-Phil;Lee, Gi-Je;Yoon, Hyung-Sang;Yoon, Seok-Am;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.192-195
    • /
    • 2004
  • Into investment expense that wind generation system that is one of clean energy is less than existent energy in narrow shipfitter maximum effect to source of energy that have Eoteulsu evaluate. There is shortcoming that Blade structure of existent aerogenerator faces at problem of safety accident in overpopulated area and noise and have additional expense of supply of electric power equipment. In this paper, We wish to supplement problem that is such through design of special Blade structure that have noise reduction and stability. Wish to achieve design and simulation of blade to use CATIA for this, and analyze adaptedness of system.

  • PDF

Housing Archetype Characterization for Developing the Energy-Efficient Retrofit Strategy in the Great Lakes Region (미국 오대호 지역내 단독주택의 에너지 효율적인 재생 방안의 수립을 위한 건축적 유형 분석)

  • Kim, Suk-Kyung;Mrozowski, Tim
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.89-96
    • /
    • 2015
  • This project was conducted as part of the Building America program that proposed the overall mission to achieve 30-50% reduction in existing building energy use. The purposes of this project were to analyze architectural styles and features named as archetypes of existing homes within the Great Lakes regions that include Michigan and identify the dominant type that would offer significant potential for energy-efficient retrofit. Housing archetypes were analyzed according to vintage, style, and construction characteristics in two target cities within the region. The findings from an intensive case study targeting the City of Ann Arbor established a fundamental framework for characterizing local housing archetypes and determined the dominant housing archetype that needed energy-efficient retrofit. An extended case study then conducted in Grand Rapids additionally refined this framework for the future application. This paper explained the process and data collection method to develop the framework that can be utilized by other researchers to determine the target housing types for energy-retrofit research.

Reaction Characteristics and Kinetics of Ni-bsed Oxygen Carrier for Chemical Looping Combustion (매체순환연소를 위한 Ni계열 산소전달입자의 반응 특성 및 반응 모델)

  • PARK, JI HYE;HWANG, RA HYUN;BAEK, JEOM-IN;RYU, HO-JUNG;YI, KWANG BOK
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.1
    • /
    • pp.90-96
    • /
    • 2018
  • Reaction characteristics and kinetics of a oxygen carrier (OCN717-R1SU) for chemical looping combustion (CLC) have been investigated using TGA by changing gas concentration (10-30 vol.% $CH_4$) and reaction temperature ($825-900^{\circ}C$). Reaction rate of OCN717-R1SU increased as temperature increased and it was found that reaction is delayed at the initial reaction regime. Johnson-Mehl-Avrami (JMA) model was adopted to explain the reaction phenomenon. The activation energy (E) determined by JMA model in reduction reaction of OCN717-R1SU is $151.7{\pm}2.03kJ/mol$ and pre-exponential factor and JMA exponent were also obtained. The parameters calculated in this study will be applied in design of the reactor and operation conditions for CLC process.