• Title/Summary/Keyword: Energy Ratio Factor

Search Result 550, Processing Time 0.029 seconds

A Study on Hammer Performance Evaluation (항타장비의 성능평가 연구)

  • 홍헌성;이명환;조천환;김성회;전영석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.405-412
    • /
    • 2002
  • The performance of a hammer/driving systems is a major factor which affects bearing capacity and integrity of installed piles. Hammer performance can be evaluated from the results of dynamic pile testing using Pile Driving Analyzer(PDA). By comparing the rated energy with measured maximum transferred energy(EMX), the energy transfer ratio(ETR) can be calculated. This paper based on the dynamic measurements of 442 cases in 130 piling projects and evaluated ETR according to the hammer types(hydraulic and drop hammers) and pile types(steel and concrete piles).

  • PDF

A study on condensation heat transfer performance in microchannel tube (마이크로 채널 관에서의 응축 열전달 성능에 관한 연구)

  • Lee, Jeong-Kun
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.22-29
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer by using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat transfer coefficient. The condensation heat transfer coefficient showed an increase as the vapor quality and mass flux increased. However, each tube shows little differences compared to 400kg/m2s or identical in case the mass flux are 200kg/m2s and 100kg/m2s. The major reason for these factors is increase-decrease of heat transfer area that the flux type of refrigerant is exposed to the coolant's vapor with the effect of channel aspect ratio or micro-fin. In addition, the heat transfer coefficient was unrelated to the heat flux, and shows a rise as the saturation temperature gets lower, an effect that occurs from enhanced density. The physical factor of heat transfer coefficient increased as the channel's aspect ratio decreased. Additionally, the micro pin at the multi-channel type tube is decided as a disadvantageous factor to condensation heat enhancement factor. That is, due to the effect of aspect ratio or micro-fin, the increase-decrease of heat transfer area that the flux type of a refrigerant is exposed to the vapor is an important factor.

Q-factor Estimation of Seismic Trace Including Random Noise using Peak Frequency-Shift Method (무작위 잡음이 포함된 탄성파 트레이스로부터 Peak Frequency-Shift 방법을 이용한 Q-factor 추정)

  • Kwon, Junseok;Chung, Wookeen;Ha, Jiho;Shin, Sungryul
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.54-60
    • /
    • 2018
  • The data acquired from seismic exploration can be used to detect the existence of oil and gas resources through appropriate processing and interpretation. The seismic attributes indicating the existence of resources are extracted from amplitude information, where the Q-factor representing intrinsic attenuation plays an useful role of hydrocarbon indicator. So, the accuracy of Q-factor estimation is very important to investigate the existence of resources. In this study, we calculated the Q-factor and analyzed the error rate through a numerical example. To mimic real data, random noise was added to the synthetic data. With the noise-added data, the Q-factor was estimated and the error rate was analyzed by using the spectral ratio method (SRM) and peak frequency shift method (PFSM). Both methods provided a relatively accurate Q-factor when the signal-to-noise ratio was 90 dB. However, the peak frequency shift method (PFSM) produced better results than the spectral ratio method (SRM) as the level of random noise increased.

An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions (부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구)

  • Choi, Sungkyung;Lee, Sang Hun;Kim, Sunjae;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

The Numerical Analysis for the Surface Crack Behavior in the Planar Solid Oxide Fuel Cell (평판형 고체산화물 연료전지 표면균열거동에 관한 수치해석)

  • Park, Cheol Jun;Kwon, Oh Heon;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.1-8
    • /
    • 2018
  • A fuel cell is an energy conversion device that converts a chemical energy directly into an electrical energy and has higher energy efficiency than an internal combustion engine, but solid oxide fuel cell (SOFC) consisting of brittle ceramic material remains as a major issue regarding the mechanical properties as the crack formation and propagation. In this study, the stress distribution and crack behavior around the crack tip were evaluated, due to investigated the effects of the surface crack at the operating condition of high temperature. As a result, the difference of the generated stress was insignificant at operating conditions of high temperature according to the surface crack length changes. This is because, the high stiffness interconnect has a closed structure to suppress cell deformation about thermal expansion. The stress intensity factor ratio $K_{II}/K_I$ increased as the crack depth increased, at that time the effect of $K_{II}$ is larger than that of $K_I$. Also the maximum stress intensity factor increased as the crack depth increased, but the location of crack was generated at the electrolyte/anode interface, not at the crack tip.

Minimum Safety Factor for Evaluation of Critical Buckling Pressure of Zirconium Alloy Tube (지르코늄 합금 관의 임계좌굴 압력 산정을 위한 최소안전율)

  • Kim, Hyung-Kyu;Kim, Jae-Yong;Yoon, Kyung-Ho;Lee, Young-Ho;Lee, Kang-Hee;Kang, Heung-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.281-287
    • /
    • 2011
  • We consider the uncertainty in the elastic buckling formula for a thin tube. We take into account the measurement uncertainty of Young's modulus and Poisson's ratio and the tolerance of the tube thickness and diameter. Elastic buckling must be prohibited for a thin tube such as a nuclear fuel rod that must satisfy a self-stand criterion. Since the predicted critical buckling pressure overestimated that found in the experiment, the determination of the minimum safety factor is crucial. The uncertainty in each parameter (i.e., Young's modulus, Poisson's ratio, thickness, and diameter) is mutually independent, so the safety factor is evaluated as the sum of the inverse of each uncertainty. We found that the thickness variation greatly affects the uncertainty. The minimum safety factor of a thin tube of Zirconium alloy is evaluated as 1.547 for a thickness of 0.87 mm and 3.487 for a thickness of 0.254 mm.

Fan Case Design using Energy Conversion Ideal Function Based Taguchi Dynamic Characteristics (에너지 전환 이상기능 기반 다구찌 동특성을 활용한 Fan Case 설계)

  • Ji, Soo Yoon;Jang, Joong Soon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.1
    • /
    • pp.97-104
    • /
    • 2015
  • An electric-motor which uses electric energy to dry laundry in a dryer generates wind by rotating a fan. The roles of electric motor and fan are crucial for drying. To reduce the noises or vibration, their performances should be improved. However, it requires a relatively high cost to redesign them. In this case, redesigning the fan case rather than the motor or the fan would be easier and cheaper. This paper is to apply Taguchi dynamic characteristic concept with the ideal function of energy conversion to redesign the fan case. Not only the increase of the wind power but also the decrease of noise, vibration and the other side effects are resulted.

Exposed Reinforced Concrete-Filled Steel Tubular (RCFST) column-base joint with high-strength

  • Mou, Ben;Wang, Zian;Qiao, Qiyun;Zhou, Wanqiu
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • The weld quality has always been an important factor affecting the development of exposed CFT column-base joint. In this paper, a new type of exposed RCFST column-base joint is proposed, in which the high strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens, the varying axial force ratio (0, 0.25 and 0.5), were tested under cyclic loadings. In addition, the bending moment capacity, energy dissipation capacity and deformation capacity of column-base joints were clarified. The experimental results indicated that the axial force ratio increases the stiffness and the bending moment and improves the energy dissipation capacity of column-base joints. This is because a large axial force can limit the slip between steel tubular and infilled concrete effectively. The specimens show stable hysteresis behavior.

Nutrition survey of young children in a day care center in the low income area of seoul (서울 시내 변두리 저소득지역 유아원 어린이의 영양실태조사)

  • 이혜상
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.2
    • /
    • pp.37-50
    • /
    • 1986
  • A nutrition survey of 128 perschool children, 4 to 6 years old, in the Saemaul Youlgok day care center, located in one uplane, overpolulated, poor area of the city of Seoul, sponsered by the Korean Red Cross Society, was undertaken between August 21 and 31, 1984, to investigate dietary and nutritional status. RESULTS: Mean values of height, weight, arm circumference, girth of chest, and head circumference ranged from 95 to 100% of KIST mean. However, 4.8~14.2% of the subjects were assessed as undernourished in terms of 'weight for height'. Mean hemoglobin vcalue was 12.1±0.7gm%, and mean hematocrit value was 38.5±2.2%; 4.1% of the subjects were proven to be anemic according to the criterion of hemoglobin established by the ICNND. Mean urinary urea nitrogen/creatinine ratio was 11.4±3.8. Regarding mean energy and nutrient intake, the following percentages had intakes below two-thirds of the 1985 RDAs: 28.8% of children, for protein; 48.8% of children, for iron; and 28.8% of children, for calcium. About 25% of children had vitamin A intake below one-third of the recommended allowance. Carbohydrate provided 71% of total energy intake; protein accounted for 13%; fat provided 16%. Energy intake was divided among breakfast, lunch, dinner and snacks in a percentage ration of 19:26:21:34. The lunch, and snacks which were served at the day care center provided 36.5~79.1% of daily energy and nutrient intake. The survey clarified that the day care feding largely supplemented the inadequate dietary intakes of these young children at home. According to factor analysis of energy and nutrient intake, there were two factor groups : the first factor group, for energy, protein, carbohydrate, iron and niacin, mainly provided by grains; and the second factor group, for calcium, vitamin A, thamin, riboflavin and ascorbic acid, provided by vegetables, fruits, milk and milk products. The survey also revealed significant correlation coefficients between family factors such as family income, educational level of parents, and number of children; and dietary or nutritional status of the subjects.

  • PDF

Flow analysis of Buoyant Jets into Storage Tank through Variable Nozzles (각종 Nozzle을 통하여 저장조내로 유입되는 BUOYANT JETS의 유동해석)

  • Pak, Ee-Tong;Cho, Woon
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.42-50
    • /
    • 1989
  • The Buoyant Jets were analysed experimentally changing flow rate (0.0291/s, 0.0371/s, 0.0451/s), ratio of nozzle tip area to throat area (aspect ratio ${\beta}$=0.4, 1.0, 1.9), and also the temperature difference (${\Delta}T=Ti-T{\infty}$) between the temperature of the inflow water into the storage tank ($1m{\times}1m{\times}3m$) and the mean temperature of the water in the storage tank were changed as $25^{\circ}C,\;35^{\circ}C$ and $45^{\circ}C$. The more aspect ratio decreased, the more the trajectories of Buoyant Jets center-line were decreased and not the more the trajectories of Buoyant Jets centerline were influenced by the increment of the difference of the temperature. The more aspect ratio decreased, the more the half widths and dilution ratio of Buoyant Jets were increased and not the more the half widths and dilution ratio of Buoyant Jets were influenced by the increment of the difference of the temperature. Fr number is the factor that can predict the flow pattern over the whole flow field. And yet for the consideration the near field of Buoyant Jets flow pattern is dominated by magnitude of momentum and buoyancy force.

  • PDF