• Title/Summary/Keyword: Energy Ratio Factor

Search Result 548, Processing Time 0.03 seconds

Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring (침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구)

  • Shin, Dong-Hwan;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.948-954
    • /
    • 2008
  • Membrane bioreactor(MBR) processes have been widely applied to wastewater treatment for last decades due to its excellent capability of solid-liquid separation. However, membrane fouling was considered as a limiting factor in wide application of the MBR process. Excess aeration into membrane surface is a common way to control membrane fouling in most MBR. However, the excessively supplied air is easily dissipated in the reactor, which results in consuming energy and thus, it should be modified for effective control of membrane fouling. In this study, cylindrical tube was introduced to MBR in order to use the supplied air effectively. Membrane fibers were immersed into the cylindrical tube. This makes the supplied air non-dissipated in the reactor so that membrane fouling could be controlled economically. Two different air supplying method was employed and compared each other; nozzle and porous diffuser which were located just beneath the membrane module. Transmembrane pressure(TMP) was monitored as a function of airflow rate, flux, and ratio of the tube area and cross-sectioned area of membrane fibers(A$_m$/A$_t$). Flow rate of air and liquid was regulated to obtain slug flow in the cylindrical tube. With the same flow of air supply, nozzle was more effective for controlling membrane fouling than porous diffuser. Accumulation of sludge was observed in the tube with the nozzle, if the air was not suppled sufficiently. Reduction of membrane fouling was dependent upon the ratio, A$_m$/A$_t$. For diffuser, membrane fouling was minimized when A$_m$/A$_t$ was 0.27, but 0.55 for nozzle.

Extraction and Complement of Hexagonal Borders in Corneal Endothelial Cell Images (각막 내피 세포 영상내 육각형 경계의 검출과 보완법)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.102-112
    • /
    • 2013
  • In this paper, two step processing method of contour extraction and complement which contain hexagonal shape for low contrast and noisy images is proposed. This method is based on the combination of Laplacian-Gaussian filter and an idea of filters which are dependent on the shape. At the first step, an algorithm which has six masks as its extractors to extract the hexagonal edges especially in the corners is used. Here, two tricorn filters are used to detect the tricorn joints of hexagons and other four masks are used to enhance the line segments of hexagonal edges. As a natural image, a corneal endothelial cell image which usually has regular hexagonal form is selected. The edge extraction of hexagonal shapes in corneal endothelial cell is important for clinical diagnosis. The proposed algorithm and other conventional methods are applied to noisy hexagonal images to evaluate each efficiency. As a result, this proposed algorithm shows a robustness against noises and better detection ability in the aspects of the output signal to noise ratio, the edge coincidence ratio and the extraction accuracy factor as compared with other conventional methods. At the second step, the lacking part of the thinned image by an energy minimum algorithm is complemented, and then the area and distribution of cells which give necessary information for medical diagnosis are computed.

Stress Intensity Factor of Cracked Plates with Bonded Composite Patch by p-Convergence Based Laminated Plate Theory (p-수렴 적층 평판이론에 의한 균열판의 팻취보강후 응력확대계수 산정)

  • Woo, Kwang-Sung;Han, Sang-Hyun;Yang, Seung-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.649-656
    • /
    • 2008
  • The enhancement of the service life of damaged or cracked structures is a major issue for researchers and engineers. The hierarchic void element based on the integrals of Legendre polynomials is used to characterize the fracture behaviour of unpatched crack as well as repaired crack with bonded composite patches by computing the stress intensity factors and stress contours at the crack tip. Since the equivalent single layer approach is adopted in this study, the proposed element is necessary to represent a discontinuous crack part as a continuum body with zero stiffness. Thus the aspect ratio of this element to represent the crack should be extremely slender. The sensitivity of numerical solution with respect to energy release rate, displacement and stress has been tested to show the robustness of zero stiffness element as the aspect ratio is increased up to 2000. The stiffness derivative method and displacement extrapolation method have been applied to calculate the stress intensity factors of Mode I problem. It is noted that the proposed hierarchical void element can be one of alternatives to analyze the patched crack problems.

New fabrication of CIGS crystals growth by a HVT method (새로운 HVT 성장방법을 이용한 CIGS 결정성장)

  • Lee, Gang-Seok;Jeon, Hun-Soo;Lee, Ah-Reum;Jung, Se-Gyo;Bae, Seon-Min;Jo, Dong-Wan;Ok, Jin-Eun;Kim, Kyung-Hwa;Yang, Min;Yi, Sam-Nyeong;Ahn, Hyung-Soo;Bae, Jong-Seong;Ha, Hong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.3
    • /
    • pp.107-112
    • /
    • 2010
  • The Cu$(In_{1-x}Ga_x)Se_2$ is the absorber material for thin film solar cell with high absorption coefficient of $1{\times}10^5cm^{-1}$. In the case of CIGS, the movable energy band gap from $CuInSe_2$ (1.00 eV) to $CuGaSe_2$ (1.68 eV) can be acquired while controlling Ga contain ratio. Generally, the co-evaporator method have used for development and fabrication of the CIGS absorption layer. However, this method should need many steps and lengthy deposition time with high temperature. For these reasons, in this paper, a new growth method of CIGS layer was attempted to hydride vapor transport (HVT) method. The CIGS mixed-source material reacted for HCl gas in the source zone was deposited on the substrate after transporting to growth zone. c-plane $Al_2O_3$ and undoped GaN were used as substrates for growth. The characteristics of grown samples were measured from SEM and EDS.

Associations between dietary patterns and hypertension among Korean adults: the Korean National Health and Nutrition Examination Survey (2008-2010)

  • Shin, Ji-Ye;Kim, Ji-Myung;Kim, Yuri
    • Nutrition Research and Practice
    • /
    • v.7 no.3
    • /
    • pp.224-232
    • /
    • 2013
  • The objective of this study is to identify the dietary patterns associated with the risk of hypertensions among Korean adults using data from the Korean National Health and Nutrition Examination Survey (KNHANES, 2008-2010). This study analyzes data from 11,883 subjects who participated in the health and nutrition survey, aging from 20 to 64 years. We performed factor analysis based on the weekly mean intake frequencies of 36 food groups to identify major dietary patterns. We identified three major dietary patterns in both sexes, namely "traditional", "western" and "dairy and carbohydrate" patterns. Participants in the highest quartile of western pattern scores had significantly higher blood pressure, serum total cholesterol, and triglyceride levels than those in the lowest quartile. Although not statistically significant, a trend (P for trend = 0.0732) toward a positive association between the western dietary pattern and hypertension risk was observed after adjustments for age, sex, education, income, body mass index (BMI), smoking, physical activity, and energy intake. The dairy and carbohydrate pattern was inversely related with BMI and blood pressures and positively associated with serum high-density lipoprotein (HDL)-cholesterol. After adjusting the age, sex, education, income, BMI, smoking, physical activity and energy intake, the dairy and carbohydrate pattern showed inverse associations with hypertension prevalence (OR = 0.64, 95% CI = 0.55-0.75; P for trend < 0.0001). Intakes of fiber, sodium, and antioxidant vitamins were significantly higher in the top quartile for the traditional pattern than in the lowest quartile for the traditional pattern (P for trend < 0.0001). Intakes of fiber (P for trend < 0.0001), calcium (P for trend < 0.0001), retinol (P for trend = 0.0164), vitamin $B_1$ (P for trend = 0.001), vitamin $B_2$ (P for trend < 0.0001), niacin (P for trend = 0.0025), and vitamin C (P for trend < 0.0001) were significantly increased across quartiles for the dairy and carbohydrate pattern whereas sodium (P for trend < 0.0001) intake was decreased for this pattern. In conclusion, the dairy and carbohydrate pattern may be associated with a reduced risk of hypertension whereas the western pattern may be associated with an increased risk of hypertension among Korean adults.

The Characteristic of Long Term Variation of the Water Quality from Hansan-Geoje bay, Korea (한산거제만 해역의 수질 장기변동 특성)

  • Kwon, Jung-No;Park, Young-Chul;Eom, Ki-Hyuk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.3
    • /
    • pp.189-201
    • /
    • 2013
  • To study characteristics of the water quality in the Hansan-Geoje bay, we analyzed the long term monitoring data collected at the two sites during the period of 1987~2010. The trophic state of the waters in Hansan-Geoje bay was the mesotrophic level by the classification of Wasmud et al.[2001]. The water nutrients increased steadily from a wet season (Aug.), it reached the maximum concentration peak in a dry season (Nov.), and then decreased steadily to the winter, it reached at the minimum value in May in the next year. The result of factor analysis divided the waters of Hansan-Geoje bay into the five factors (nutrient, season, inflow land water, pollution, internal production) and the factors represented the 76.82% on the status of the waters. According to time series analysis, temperature, DO and bottom DIP were increased, and pH and COD were decreased during the period of 1987~2010. In particular, the fluctuation trend of DIN has been turned from oversupply to shortage by the N/P ratio since before and after 1990's. The water quality of the Hansan-Geoje bay has been recovered except DIP since 1987, despite of its geographical characteristic which is a general semi-closesd bay and a massive aqua-culture ground. To preserve the waters in Hansan-Geoje bay, we need to know on the cause of the increase or accumulation of DIP, and we should continue to study on the interrelation between the aqua-culture and water environment.

Comparison of Radiofrequency Ablation and Cryoablation for the Recovery of Atrial Contractility and Survival

  • Kim, Kang Min;Chung, Suryeun;Kim, Sang Yoon;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.266-272
    • /
    • 2018
  • Background: Limited comparative data are available on the efficacy of cryoablation versus radiofrequency ablation in patients with atrial fibrillation. This study aimed to compare radiofrequency ablation and cryoablation with regard to clinical outcomes and the restoration of sinus rhythm or atrial contractility. Methods: A total of 239 patients who underwent surgical ablation between August 2003 and December 2016 at our institution were included. The patients were divided into 2 groups according to the energy device that was used (group A: n=140, radiofrequency ablator; group B: n=99, cryoablator). Echocardiographic data, overall survival, and major cardiovascular and cerebrovascular event (MACCE)-free survival were compared between the 2 groups. Results: At 1 year of follow-up, the atrial contractility recovery rate was 32.2% (19 of 59) in group A and 48.8% (21 of 44) in group B. In addition, cryoablation was found to be a predictive factor for the recovery of atrial contractility (cryoablation vs. radiofrequency ablation: odds ratio, 2.540; 95% confidence interval, 1.063-6.071; p=0.036). The left ventricular ejection fraction was significantly higher in group B ($53.1%{\pm}11.5%$ vs. $59.1%{\pm}6.3%$, p=0.001). The median follow-up duration was 36 months. The 5-year overall survival rate was $80.1%{\pm}3.6%$ in group A and $92.1%{\pm}2.9%$ in group B (p=0.400). The 5-year MACCE-free survival rate was $70.3%{\pm}4.0%$ in group A and $70.9%{\pm}5.6%$ in group B (p=0.818). Conclusion: Cryoablation was associated with a higher atrial contractility restoration rate and better left ventricular function than radiofrequency ablation. However, no significant relationship was observed between the energy source and overall or MACCE-free survival.

A Numerical Study of the Effects of Heat Transfer and Fluid Flow on Tube Insertion Length in Computer-Cooling Radiators (컴퓨터 CPU 냉각용 방열기 튜브 삽입길이에 따른 열유동 해석)

  • Choi, Jin-Tae;Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • The performance of flat-tube radiators with louvered fins was numerically investigated for different tube insertion lengths. The results of numerical analysis using CFX-11 were compared with experimental results. In this study, three types of flat-tube radiators with louvered fins were considered. An experiment was conducted to validate the numerical results. Flow rate ratio (FR) and Stotal were introduced to understand the uniformity of flow distribution easily. The results of numerical analysis revealed that the heat transfer rate and pressure drop increased as the mass flow rate increased. Further, the results showed that the heat transfer rate of sample 3 with h/D = 0.5 was higher than that of the other samples. The pressure drop increased as the insertion length toward the header part increased, and the pressure drop in the case of sample 3 appeared to be the highest. The factor Stotal showed that the uniformity of the flow distribution in the case of sample 1 with h/D = 0 was higher than that in the case of the other samples.

Synthesis and Photovoltaic Properties of New π-conjugated Polymers Based on Benzo[1,2,5]thiadiazole (Benzo[1,2,5]thiadiazole을 기본 골격으로 한 공액고분자의 합성 및 광전변환특성 연구)

  • Bea, Jun Huei;Lim, Gyeong Eun;Kim, Joo Hyun
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.396-401
    • /
    • 2013
  • Alternating copolymers, poly[9-(2-octyl-dodecyl)-9H-carbazole-alt-4,7-di-thiophen-2-yl-benzo[1,2,5]thiadiazole] (PCD20TBT) and poly[9,10-bis-(2-octyl-dodecyloxy)-phenanthrene-alt-4,7-di-thiophen-2-yl-benzo[1,2,5]thiadiazole] (PN40TBT), were synthesized by the Suzuki coupling reaction. The copolymers were soluble in common organic solvents such as chloroform, chlorobenzene, 1,2-dichlorobenzene, tetrahydrofuran and toluene. The maximum absorption wavelength and the band gap of PCD20TBT were 535 nm and 1.75 eV, respectively. The maximum absorption wavelength and the band gap of PN40TBT were 560 nm and 1.97 eV, respectively. The HOMO and the LUMO energy level of PCD20TBT were -5.11 eV and -3.36 eV, respectively. As for PN40TBT, the HOMO and the LUMO energy level of PCD20TBT were -5.31 eV and -3.34 eV, respectively. The polymer solar cells (PSCs) based on the blend of copolymer and PCBM (1 : 2 by weight ratio) were fabricated. The power conversion efficiencies of PSCs based on PCD20TBT and PN40TBT were 0.52% and 0.60%, respectively. The short circuit current density ($J_{SC}$), fill factor (FF) and open circuit voltage ($V_{OC}$) of the device with PCD20TBT were $-1.97mA/cm^2$, 38.2% and 0.69 V. For PN40TBT, the $J_{SC}$, FF, and $V_{OC}$ were $-1.77mA/cm^2$, 42.9%, and 0.79 V, respectively.

Quasi-Static Test for Seismic Performance of Circular Hollow RC Bridge Pier (원형 중공 콘크리트 교각의 내진성능에 대한 준정적 실험)

  • 정영수;한기훈;이강균;이대형
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.41-54
    • /
    • 1999
  • Because of relatively heavy dead weight of concrete itself and unavoidable heat of massive concrete in bridge piers, circular hollow columns are widely used in Korean highway bridges. Since the occurrence of 1995 Kobe earthquake, there have been much concerns about seismic design for various infrastructures, inclusive of bridge structures. It is, however, understood that there are not much research works for nonlinear behavior of circular hollow columns subjected to eqrthquake motions. The objective of this experimental research is to investigate nonlinear behavior of circular hollow reinforced concrete bridge piers under the quasi-static cyclic load, and then to enhance their ductility by strengthening the plastic hinge region with glassfiber sheets. Particularly for this test, constant 10 cyclic loads have been repeatedly actuated to investigate the magnitude of strength degradation for the displacement ductility factor. Important test parameters are seismic design, confinement steel ratio, axial force and load pattern. It is observed from quasi-static tests for 7 bridge piers that the seismically designed columns and the retrofitted columns show better performance than the nonseismically designed colums, i.e. about 20% higher for energy dissipation capacity and about 70% higher for curvatures.

  • PDF