• 제목/요약/키워드: Energy Matching

검색결과 308건 처리시간 0.027초

Structure-property relations for polymer melts: comparison of linear low-density polyethylene and isotactic polypropylene

  • Drozdov, A.D.;Al-Mulla, A.;Gupta, R.K.
    • Advances in materials Research
    • /
    • 제1권4호
    • /
    • pp.245-268
    • /
    • 2012
  • Results of isothermal torsional oscillation tests are reported on melts of linear low density polyethylene and isotactic polypropylene. Prior to rheological tests, specimens were annealed at various temperatures ranging from $T_a$ = 180 to $310^{\circ}C$ for various amounts of time (from 30 to 120 min). Thermal treatment induced degradation of the melts and caused pronounced decreases in their molecular weights. With reference to the concept of transient networks, constitutive equations are developed for the viscoelastic response of polymer melts. A melt is treated as an equivalent network of strands bridged by junctions (entanglements and physical cross-links). The time-dependent response of the network is modelled as separation of active strands from and merging of dangling strands with temporary nodes. The stress-strain relations involve three adjustable parameters (the instantaneous shear modulus, the average activation energy for detachment of active strands, and the standard deviation of activation energies) that are determined by matching the dependencies of storage and loss moduli on frequency of oscillations. Good agreement is demonstrated between the experimental data and the results of numerical simulation. The study focuses on the effect of molecular weight of polymer melts on the material constants in the constitutive equations.

Steady- and Transient-State Analyses of Fully Ceramic Microencapsulated Fuel with Randomly Dispersed Tristructural Isotropic Particles via Two-Temperature Homogenized Model-I: Theory and Method

  • Lee, Yoonhee;Cho, Bumhee;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.650-659
    • /
    • 2016
  • As a type of accident-tolerant fuel, fully ceramic microencapsulated (FCM) fuel was proposed after the Fukushima accident in Japan. The FCM fuel consists of tristructural isotropic particles randomly dispersed in a silicon carbide (SiC) matrix. For a fuel element with such high heterogeneity, we have proposed a two-temperature homogenized model using the particle transport Monte Carlo method for the heat conduction problem. This model distinguishes between fuel-kernel and SiC matrix temperatures. Moreover, the obtained temperature profiles are more realistic than those of other models. In Part I of the paper, homogenized parameters for the FCM fuel in which tristructural isotropic particles are randomly dispersed in the fine lattice stochastic structure are obtained by (1) matching steady-state analytic solutions of the model with the results of particle transport Monte Carlo method for heat conduction problems, and (2) preserving total enthalpies in fuel kernels and SiC matrix. The homogenized parameters have two desirable properties: (1) they are insensitive to boundary conditions such as coolant bulk temperatures and thickness of cladding, and (2) they are independent of operating power density. By performing the Monte Carlo calculations with the temperature-dependent thermal properties of the constituent materials of the FCM fuel, temperature-dependent homogenized parameters are obtained.

Analysis of system dynamic influences in robotic actuators with variable stiffness

  • Beckerle, Philipp;Wojtusch, Janis;Rinderknecht, Stephan;von Stryk, Oskar
    • Smart Structures and Systems
    • /
    • 제13권4호
    • /
    • pp.711-730
    • /
    • 2014
  • In this paper the system dynamic influences in actuators with variable stiffness as contemporary used in robotics for safety and efficiency reasons are investigated. Therefore, different configurations of serial and parallel elasticities are modeled by dynamic equations and linearized transfer functions. The latter ones are used to identify the characteristic behavior of the different systems and to study the effect of the different elasticities. As such actuation concepts are often used to reach energy-efficient operation, a power consumption analysis of the configurations is performed. From the comparison of this with the system dynamics, strategies to select and control stiffness are derived. Those are based on matching the natural frequencies or antiresonance modes of the actuation system to the frequency of the trajectory. Results show that exclusive serial and parallel elasticity can minimize power consumption when tuning the system to the natural frequencies. Antiresonance modes are an additional possibility for stiffness control in the series elastic setup. Configurations combining both types of elasticities do not provide further advantages regarding power reduction but an input parallel elasticity might enable for more versatile stiffness selection. Yet, design and control effort increase in such solutions. Topologies incorporating output parallel elasticity showed not to be beneficial in the chosen example but might do so in specific applications.

Performance Prediction of an OWC Wave Power Plant with 3-D Characteristics in Regular Waves

  • Hong, Do-Chun;Hong, Keyyong
    • 한국항해항만학회지
    • /
    • 제36권9호
    • /
    • pp.729-735
    • /
    • 2012
  • The primary wave energy conversion by a three-dimensional bottom-mounted oscillating water column (OWC) wave power device in regular waves has been studied. The linear potential boundary value problem has been solved following the boundary matching method. The optimum shape parameters such as the chamber length and the depth of the front skirt of the OWC chamber obtained through two-dimensional numerical tests in the frequency domain have been applied in the design of the present OWC chamber. Time-mean wave power converted by the OWC device and the time-mean second-order wave forces on the OWC chamber structure have been presented for different wave incidence angles in the frequency-domain. It has been shown that the peak period of $P_m$ for the optimum damping parameter coincides with the peak period of the time.mean wave drift force when ${\gamma}=0$.

반도체 Ash 공정용 PWM 제어 Plasma 발생방법 (Plasma Generation Method using PWM Control for Ash Process)

  • 이정호;최대규;최상돈;이병국;원충연;김수석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.470-474
    • /
    • 2006
  • This dissertation discuses about a ferrite core plasma source using low operating frequency without sputtering problem by the stored electric field. Compared with the conventional RF power system with 13.56MHz switching frequency, the proposed plasma power system is only separated at 400kHz, so that it makes possible to use of low cost switching elements, PWM control and soft switching. Moreover, it could improve the coupling efficiency for plasma and antenna by using the ferrite core in order to transfer the energy of the load This dissertation tried to analyze new plasma generation method for the plasma generation system by modeling the plasma load and grafting the concept of impedance matching in order to interpret it with the formula This dissertation verified the ferrite core inductive coupling plasma source authorized for 400kHz of low frequency power by applying to the semi-conductor ash process thru the measurement of ash capacity and uniformed plasma distribution on the actual wafer.

  • PDF

Preparation and Electromagnetic Properties of an Electromagnetic Wave Absorber

  • Sun, Chang;Sun, Kangning;Pang, Laixue;Liu, Jian
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.61-64
    • /
    • 2016
  • In this study, we report the as-prepared MgO-doped $BaFe_{12}O_{19}$, which was prepared by calcination technique and high-energy ball milling process, as an electromagnetic wave absorber. The phase analysis of $BaFe_{12}O_{19}$ and the as-prepared MgO-doped $BaFe_{12}O_{19}$ was detected utilizing X-ray Diffractometer (XRD). The microstructure was characterized using Scanning Electron Microscope (SEM). By means of the transmission/reflection coaxial line method, the electromagnetic properties and microwave absorbing properties of the as-prepared electromagnetic wave absorber were studied. It is found that the electromagnetic wave absorber has a minimum reflection loss value of -41 dB at 4.27 GHz with a matching thickness of 2.6 mm. The experiment results revealed that the as-prepared electromagnetic wave absorber could find potential applications in many military as well as commercial industries.

역T형 옹벽의 지진시 거동특성 Part II : 입력 지진파의 영향 (Seismic Behavior of Inverted T-type Wall under Earthquake Part II : Effect of Input Earthquake Motion)

  • 이진선
    • 한국지진공학회논문집
    • /
    • 제20권1호
    • /
    • pp.9-19
    • /
    • 2016
  • Permanent deformation plays a key role in performance based earthquake resistant design. In order to estimate permanent deformation after earthquake, it is essential to secure reliable response history analysis(RHA) as well as earthquake scenario. This study focuses on permanent deformation of an inverted T-type wall under earthquake. The study is composed of two separate parts. The first one is on the verification of RHA and the second one is on an effect of input earthquake motion. The former is discussed in companion paper and the latter in this paper. In order to investigate the effect of an input earthquake motion on the permanent deformation, three bins of spectral matched real earthquake records with different magnitude, regions, epicentral distance are constructed. Parametric study was performed using the verified RHA through the companion paper for each earthquake records in the bins. The most influential parameter affecting permanent displacement is magnitude. The other parameters describing earthquake motion are not significant enough to increase permanent displacement of the inverted T-type wall except for energy related parameters(AI, CI, SEI).

형광램프 수명말기 표시기능 검측회로 개발 (A Indication Functional Inspection circuit development for Fluorescent ramp end of life (EOL))

  • 홍사근;최홍규;이근무;윤철구;최대원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2008
  • 형광등은 방전등의 일종으로 방전현상을 이용하여 전기에너지를 빛으로 변환하는 광원으로 램프의 점등 시에 나타나는 부저항 특성 때문에 반드시 점등회로를 필요로 한다. 방전등의 광원특성과 안정기의 변환특성은 밀접한 관련을 가지고 있다. 따라서 양 특성의 정합성립을 위하여 사용조건 및 경제성을 고려한 최적회로 설계지침을 내놓는 것은 매우 중요하다. 본 논문에서는 형광등용 전자안정기에 있어 부하인 형광램프의 수명말기에 나타나는 화재, 광효율 저감 등 여러 가지 문제점을 개선할 수 있는 수명말기 검측과 수명말기 표시기능 개발에 대하여 고찰해본다.

  • PDF

Location Error Analysis of an Active RFID-Based RTLS in Multipath and AWGN Environments

  • Myong, Seung-Il;Mo, Sang-Hyun;Yang, Hoe-Sung;Cha, Jong-Sub;Lee, Heyung-Sub;Seo, Dong-Sun
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.528-536
    • /
    • 2011
  • In this paper, we analyze the location accuracy of real-time locating systems (RTLSs) in multipath environments in which the RTLSs comply with the ISO/IEC 24730-2 international standard. To analyze the location error of RTLS in multipath environments, we consider a direct path and indirect path, in which time and phase are delayed, and also white Gaussian noise is added. The location error depends strongly on both the noise level and phase difference under a low signal-to-noise ratio (SNR) regime, but only on the noise level under a high SNR regime. The phase difference effect can be minimized by matching it to the time delay difference at a ratio of 180 degrees per 1 chip time delay (Tc). At a relatively high SNR of 10 dB, a location error of less than 3 m is expected at any phase and time delay value of an indirect signal. At a low SNR regime, the location error range increases to 8.1 m at a 0.5 Tc, and to 7.3 m at a 1.5 Tc. However, if the correlation energy is accumulated for an 8-bit period, the location error can be reduced to 3.9 m and 2.5 m, respectively.

Development of Analog Gauge Recognition System Using Morphological Operation and Periodic Measurement Function

  • Ryu, Jin-kyu;Kwak, Young-Tae
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권2호
    • /
    • pp.27-34
    • /
    • 2018
  • In this paper, we propose a new method to read the hand of analog gauges to prepare for the smart factory. In addition, we suggest a new and improved method that can apply, in general, diverse analog gauges even if their scale types and ranges are various. Many companies are making great efforts to build smart factories that increase energy efficiency and automation. Managers use a variety of equipment and tools to manage the production process at the factory. In this kind of factory, analog gauges have been often used with many equipment and tools. Analog gauges are mostly circular in shape, and most papers use circular hough transform to find the center and radius of a circle. However, when the object to be found is not of the correct circle type, it takes a long time to recognize the circle using the circular hough transform, and the center and radius of the circle can not be calculated accurately. The proposed method was tested on various circular analog gauges. As a result, we confirmed that our method is outstanding.