• Title/Summary/Keyword: Energy Management System

Search Result 2,234, Processing Time 0.032 seconds

A Study on the Establishing Good Quality System for Economic Quality Management (경제적(經濟的) 품질경영(品質經營)을 위한 Good Quality System 확보(確保) 방안(方案))

  • Kim, Young-Sea;Hong, Kyung-Sik
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.1
    • /
    • pp.115-126
    • /
    • 1995
  • This paper describes the method of establishing good quality system, developed to improve the effectiveness and efficiency of designing or revising quality system, based on the engineering approach. This is one approach, but with small modification, its method is applicable not only to the quality system, but to the entire management system in an organization. The best quality system is one's own system, and it must be kept simple, complete and economic.

  • PDF

Study of Bidirectional DC-DC Converter Interfacing Energy Storage for Vehicle Power Management Using Real Time Digital Simulator (RTDS)

  • Deng, Yuhang;Foo, Simon Y.;Li, Hui
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.479-489
    • /
    • 2011
  • The bidirectional dc-dc converter, being the interface between Energy Storage Element (ESE) and DC bus, is an essential component of the power management system for vehicle applications including electric vehicle (EV), hybrid electric vehicle (HEV), and fuel cell vehicle (FCV). In this paper, a novel multiphase bidirectional dc-dc converter interfacing with battery to supply and absorb the electric energy in the FCV system was studied with the help of real time digital simulator (RTDS). The mathematical models of fuel cell, battery and dc-dc converter were derived. A power management strategy was developed and first simulated in RTDS. A Power Hardware-In-the-Loop (PHIL) simulation using RTDS is then presented. The main challenge of this PHIL is the requirement for a highly dynamic bidirectional Simulation-Stimulation (Sim-Stim) interface. This paper describes three different interface algorithms. The closed-loop stability of the resulting PHIL system is analyzed in terms of time delay and sampling rate. A prototype bidirectional Sim-Stim interface is designed to implement the PHIL simulation.

A Study on the Residential Energy Management of Apartment in the District Heating Area (지역난방 아파트의 난방 관리 실태에 관한 연구)

  • 최남숙
    • Journal of Families and Better Life
    • /
    • v.7 no.1
    • /
    • pp.79-95
    • /
    • 1989
  • Household energy consumption had influenced on the ecological system's environment. Household's exceeding energy consumption requires the development of resources and the risk. Thus this study attempted to find the household heating management, The purpose of this study was to investigate the household's heating management in the area of district heating. The major finding were; 1) The district heating was accepted positively and the benefit of this system was utilized very well in the household. 2) Variances in heating energy consumption was explained by the family size at October, residential period at October and November and the temperature of living room at October, November and December. 3) Compaired to central heating apartment, the low heating expenditure was characterize in the household of 4-5 persons, nuclear family at October, moderated heating control, using extra heating facilities at November. An in the December, that household was that husband has graduated college, temperature of the living room was some cold, and house wives was the full-time homemaker.

  • PDF

Development of an Operator Aid System For The Nuclear Plant Severe Accident Training and Management

  • Kim Ko Ryu;Park Sun Hee;Kim Dong Ha
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2004
  • Recently KAERI has developed the severe accident management guidance to establish Korea standard severe accident management system. On the other hand the PC-based severe accident training simulator SATS has been developed, and the MELCOR code is used as the simulation engine. SATS graphically displays and simulates the severe accidents with interactive user commands. The control capability of SATS could make a severe accident training course more interesting and effective. In this paper the development and functions of the electrical hypertext guidance module HyperKAMG and the SATS-HyperKAMG linkage system for the severe accident management are described.

Development of Container House Equipped with Sensing and Environmental Monitoring System Based on Photovoltaic/Diesel Hybrid System (태양광/디젤 하이브리드 시스템 기반 센서 구동 및 환경 모니터링 컨테이너 하우스 개발)

  • Mi-Jeong Park;Jong-Yul Joo;Eung-Kon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • The mobile house of this article is provided with stand-alone power system that uses photovoltaic energy and enables sensing and environmental monitoring. Excess power generated is stored in lithium batteries, which enable smooth operation of the mobile house even in environment in which solar energy cannot be used. The house has been designed that its systems can be operated continuously by diesel power generation even when photovoltaic energy cannot be generated due to long rainy season or heavy snow. BMS (batter management system) has been constructed for photovoltaic and power management, and monitors the charge/discharge and usage amount of photovoltaic energy. Various sensing data are recorded and transmitted automatically, and the design allows for wireless monitoring by means of computer and smartphone app. The container house proposed in this study enables efficient energy management by performing optimal energy operation in remote areas, parks, event venues, and construction sites where there is no system power source.

Design of a renewable energy system with battery and power-to-methanol unit

  • Andika, Riezqa;Kim, Young;Yun, Choa Mun;Yoon, Seok Ho;Lee, Moonyong
    • Korean Journal of Chemical Engineering
    • /
    • v.36 no.1
    • /
    • pp.12-20
    • /
    • 2019
  • An energy storage system consisting of a battery and a power-to-methanol (PtM) unit was investigated to develop an energy storage system for renewable energy systems. A nonlinear programming model was established to optimize the energy storage system. The optimal installation capacities of the battery and power-to-methanol units were determined to minimize the cost of the energy system. The cost from a renewable energy system was assessed for four configurations, with or without energy storage units, of the battery and the power-to-methanol unit. The proposed model was applied to the modified electricity supply and demand based on published data. The results show that value-adding units, such as PtM, need be included to build a stable renewable energy system. This work will significantly contribute to the advancement of electricity supply and demand management and to the establishment of a nationwide policy for renewable energy storage.

Distributed Dynamic Lighting Energy Management System based on Zigbee Mesh Network (지그비 메쉬망 기반 분산형 동적 에너지 관리 시스템)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.85-91
    • /
    • 2014
  • Nowadays, Dynamic lighting control and management skills are studied and used. If the system which is to manage multiple intelligent spot applied ubiquitous service technology is built with decision making and used in the complex intelligent space like a apartment then will improve energy efficiency and provide comfortability in optimal conditions. To solve this problem distributed autonomous control middleware and energy management system which process data gathering by zigbee mesh network and search proper services to save energy by the existing state of things is necessary. In paper we designed DDLEMS (Distributed Dynamic Lighting Energy Management System) that is to service duplex communication embedded by software based home server platform to provide mobile services in the smart place and support decision making about energy saving to the best use of wireless censor node and controled network, energy display devices.

RADIATION MONITORING SYSTEM FOR ADVANCED SPENT FUEL CONDITIONING PROCESS FACITLITY

  • Kook Dong-Hak;Choung Won-Myung;Lee Eun-Pyo;You Gil-Sung;Cho Il-Je;Kwon Kie-Chan;Lee Won-Kyoung;Ku Jeoung-Hoe
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.149-155
    • /
    • 2005
  • The $ACP^1$ is under development for effective management of spent fuel by converting $UO_2$ into U-metal. For demonstration of this process, $\alpha-\gamma$ type new hotcell was built in the $IMEF^2$ basement. To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hotcell and service area at back of it. This system consists of 7 parts; Area Monitor for $\gamma$-ray, Room Air Monitor for particulate and iodine in both area, Hotcell Monitor for hotcell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  • PDF

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

The Case Study on the Niche Experimentation in Offshore Wind Renewable Energy Transition (해상풍력 기술의 사회-기술시스템 전환과정에 관한 탐색적 사례연구)

  • Kim, Bonggyun;Kim, Dukyoung;Kim, Kyungnam;Kim, Donghwan
    • Journal of Korea Technology Innovation Society
    • /
    • v.17 no.2
    • /
    • pp.355-379
    • /
    • 2014
  • For the transition to the low carbon society, it is inevitable but difficult journey that the new energy technology spread co-exists with formal social system. The objective of offshore wind power plant that has been implemented by the government is to connect large capacity new renewable energy to the central electric power system. Therefore, for the successful introduction of offshore wind power system, the transition of the formal social technology system should be companied. This study analysis the energy system transition about niche strategy adjustment using Multiple Level Perspectives & Strategic Niche Management. It also multi level analyzes and structuralizes the process that new technology, as a research result, evolves through connecting and communicating with formal regime and landscape. Also, adjusting Strategic Niche Management, it diagnoses the obstructive factors in the initial stage of niche experiment and found the major reasons why offshore wind power test plant had been delayed. Through this study, it reaches to the practical implication that offshore niche technology could grow stably in the energy system and various policies.