• 제목/요약/키워드: Energy Efficiency Factor

검색결과 740건 처리시간 0.03초

신재생에너지 발전(태양광, 풍력, 소수력, 바이오가스)의 경제성 분석 연구 (A study on economic analysis of new renewable energy power(photovoltaic, wind power, small hydro, biogas))

  • 김종민;김기영
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study evaluates a feasibility and economical efficiency of new renewable energy. According as weather change is serious problem now days, every people make attention to the reduction of greenhouse gas. The revitalization of new renewable energy creates the variety of energy source, stability of energy supply and reduction of greenhouse gas. In this study evaluates a feasibility and economical efficiency from new renewable energy of various photo voltaics, wind power, small hydro and biogas. Feasibility does in standard of technical characteristic, politic support, marketability, establishment present condition and development aim. Economical efficiency does in standard of developmental unit cost, utilization factor, equipment life, politic support cost, interest ratio. The results of this study were as follows photo voltaics, wind, small hydropower, biogas in order feasibility is high. Developmental unit cost, utilization factor, equipment life, politic support cost and analyzed the relationship of interest ratio fluctuation and economical efficiency. From all new renewable energy the utilization factor most is important in economical efficiency but necessary utilization factor is difficult because environmental problem.

자본회수계수를 고려한 고효율 생산설비의 경제성분석 (Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor)

  • 박형준;정찬수
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.117-123
    • /
    • 2007
  • 제조업에서 생산설비에 사용되는 중요한 에너지원 중 하나는 전력에너지이며, 에너지 다소비 업종의 생산설비 즉, 플랜트에서는 사용하는 에너지의 절감과 효율 운전은 매우 중요한 관심사항이다. 본 논문에서는 생산 플랜트의 한 공정에서 가장 빈번히 사용되는 유도전동기를 모델로 하여 실제 진단, 계측을 통하여 측정값을 얻고, 기존의 운전 중인 설비들을 고효율 기기로 교체하였을 경우의 경제성을 분석하였다. 이를 위해서 현재 운전 중인 설비와 고효율설비로 교체하였을 경우에 대하여 각각 설비들의 연간 운전비용과 자본회수계수에 의한 연간 투자비용을 계산하였고, 이를 합산한 연간 총 운용비용을 비교하여 고효율설비의 경제적 타당성을 입증하였다.

심벌형 압전 에너지 하베스터 에너지 수율 향상 연구 (Research on the Efficiency Improvement of the Cymbal-type Piezoelectric Energy Harvester)

  • 나영민;박종규
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2017
  • The pollution problem of fossil energy sources has caused the development of green energy harvesting systems. Piezoelectric energy harvesting technology has been developed under those external environmental factors. A piezoelectric energy harvester can be defined as a device which transforms mechanical vibration or impact energy into electrical energy. Most researches have focused on bender structures. However, these have a limitation on energy efficiency because of the small effective electromechanical coupling factor, around 10%. Therefore, we should look for a new design for energy harvesting. A cymbal energy harvester can be a good candidate for the high-power energy harvester because it uses a high amplification mechanism using endcaps while keeping a higher electromechanical coupling factor. In this research, we focused on energy efficiency improvements of the cymbal energy harvester by changing the polarization direction, because the electromechanical coupling factor of the k33 mode and the k15 mode is larger than that of the k31 mode. Theoretically, we checked the cymbal harvester with radial polarization and it could obtain 6 times larger energy than that with the k31 direction polarization. Furthermore, we verified the theoretical expectation using the finite element method program. Consequently, we could expect a more efficient cymbal harvester with the radial polarization by comparing two polarization directions.

결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터 (New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권10호
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구 (Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio)

  • 이나은;안병립;정학근;김종훈;장철용
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

생산설비에서 에너지효율 산정 (Energy Efficiency Calculations of the Production Facilities)

  • 박형준;정찬수
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2007
  • 원유가의 급등과 더불어 에너지자원에 대한 관심이 크게 증가 되었는데, 다양한 에너지관련 분야 중에서 먼저 선행되어야 하는 것은 기존의 설비에서 사용하고 있는 에너지가 효과적으로 사용되고 있는가를 판단하는 것이며, 이를 에너지 효율의 산정이라고 한다. 따라서 본 논문에서는 에너지의 주요 수요처중 하나인 제지 생산 플랜트의 한 공정에서 전력에너지와 열에너지에 대한 에너지효율을 계산하였다. 이때 전력에너지는 운전 중인 전동기의 부하에 따른 효율을 중심으로, 열에너지는 공정에서 입출력되는 열량을 중심으로 계산하였다. 즉 운전 중인 생산설비의 한 공정의 전력과 열에너지에 대해 각각 에너지효율을 산정하였으며 일부 에너지절감에 대한 방안도 제시하였다.

에너지 흡수효율에 의한 철근콘크리트 구조물의 감쇠비 수정계수 결정 (Determination of Damping Modification Factor in RC Structures Due to Energy Absorption Efficiency)

  • 김장훈;좌동훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.161-166
    • /
    • 2002
  • The modification factor( k-factor) of equivalent damping ratio utilized in the current state-of-the-practice to account for the imperfection of reinforced concrete structures in hysteresis loop is investigated. From this, it is found that the current modification factor does not include the effect of cyclic loading, one of the important characteristic properties of earthquake loading. This could be taken into account by considering the energy absorption efficiency based on the cummulative plastic deformation. From the study, it is suggested that the current approach for the modification factor for the equivalent damping ratio should be reformed.

  • PDF

인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향 (The effect on the seasonal performance of an inverter compressor with higher and lower operating range)

  • 박윤철;하도용;민만기
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

우리나라 16개 시·도의 제조업부문 총요소 에너지 효율성 및 결정요인 분석 (Regional Total Factor Energy Efficiency and its Determinants of the Korean Manufacturing Sector)

  • 박창수;서윤석
    • 지역연구
    • /
    • 제33권1호
    • /
    • pp.3-16
    • /
    • 2017
  • 본 논문은 에너지 효율성 지표로써 투입물로 에너지뿐만 아니라 노동과 자본 등을 동시에 고려한 총요소 에너지 효율성을 DEA에 기초하여 2005-2013년 기간 동안 우리나라 16개 시 도의 제조업 부문에 대하여 추정하였다. 추정결과에 의하면, 단일요소 에너지 효율성과 총요소 에너지 효율성 간에 차이가 존재하여 두 지표를서로 보완적으로 사용할 필요성이 있는 것으로 나타났다. 한편, 총요소 에너지 효율성 지표는 대부분의 시 도들에서 높게 나타났는데 서울, 광주, 울산, 경북 등은 프런티어에 위치하지만, 강원, 부산, 대구, 인천 등은 상대적으로 매우 비효율적인 것으로 나타났다. 또한 패널 토빗 모형을 통해 총요소 에너지 효율성의 결정 요인을 추정한 결과에 의하면, 대기업의 생산액 비중이 클수록, 에너지 다소비업종의 생산액 비중이 작을수록, 그리고 전력 사용 비중이 클수록, 총요소 에너지 효율성에 긍정적인 영향을 주는 것으로 추정되었다.

TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석 (Analysis of TV Standby Power for Development of Energy Efficiency Standard)

  • 김익표;노경수
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.