• Title/Summary/Keyword: Energy Efficiency Factor

Search Result 740, Processing Time 0.025 seconds

A study on economic analysis of new renewable energy power(photovoltaic, wind power, small hydro, biogas) (신재생에너지 발전(태양광, 풍력, 소수력, 바이오가스)의 경제성 분석 연구)

  • Kim, Chong-Min;Kim, Ki-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study evaluates a feasibility and economical efficiency of new renewable energy. According as weather change is serious problem now days, every people make attention to the reduction of greenhouse gas. The revitalization of new renewable energy creates the variety of energy source, stability of energy supply and reduction of greenhouse gas. In this study evaluates a feasibility and economical efficiency from new renewable energy of various photo voltaics, wind power, small hydro and biogas. Feasibility does in standard of technical characteristic, politic support, marketability, establishment present condition and development aim. Economical efficiency does in standard of developmental unit cost, utilization factor, equipment life, politic support cost, interest ratio. The results of this study were as follows photo voltaics, wind, small hydropower, biogas in order feasibility is high. Developmental unit cost, utilization factor, equipment life, politic support cost and analyzed the relationship of interest ratio fluctuation and economical efficiency. From all new renewable energy the utilization factor most is important in economical efficiency but necessary utilization factor is difficult because environmental problem.

Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor (자본회수계수를 고려한 고효율 생산설비의 경제성분석)

  • Park, Hyung-Joon;Chung, Chcn-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.117-123
    • /
    • 2007
  • This paper is about the economic analysis of the replacement of electric facilities in the production facilities. As the interest of energy is increasing, the efficiency of facilities become more important. So, in this paper, we diagnosed facilities, especially electric motors, in the plant and calculated the operating efficiency, power loss with the load factor. And when we replace these facilities into high-efficiency motors, we also calculated new energy efficiency, energy loss and economic analysis through capital recovery factor. As a result, we economically proved that using high-efficiency motor is more beneficial than using non-high-efficiency motors in the model process.

Research on the Efficiency Improvement of the Cymbal-type Piezoelectric Energy Harvester (심벌형 압전 에너지 하베스터 에너지 수율 향상 연구)

  • Na, Yeong-Min;Park, Jong-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.70-76
    • /
    • 2017
  • The pollution problem of fossil energy sources has caused the development of green energy harvesting systems. Piezoelectric energy harvesting technology has been developed under those external environmental factors. A piezoelectric energy harvester can be defined as a device which transforms mechanical vibration or impact energy into electrical energy. Most researches have focused on bender structures. However, these have a limitation on energy efficiency because of the small effective electromechanical coupling factor, around 10%. Therefore, we should look for a new design for energy harvesting. A cymbal energy harvester can be a good candidate for the high-power energy harvester because it uses a high amplification mechanism using endcaps while keeping a higher electromechanical coupling factor. In this research, we focused on energy efficiency improvements of the cymbal energy harvester by changing the polarization direction, because the electromechanical coupling factor of the k33 mode and the k15 mode is larger than that of the k31 mode. Theoretically, we checked the cymbal harvester with radial polarization and it could obtain 6 times larger energy than that with the k31 direction polarization. Furthermore, we verified the theoretical expectation using the finite element method program. Consequently, we could expect a more efficient cymbal harvester with the radial polarization by comparing two polarization directions.

New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit (결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio (창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jeong, Hak-Geun;Kim, Jong-Hun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

Energy Efficiency Calculations of the Production Facilities (생산설비에서 에너지효율 산정)

  • Park, Hyung-Joon;Chung, Chan-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2007
  • This paper is about the energy efficiency calculation of the production facilities. In the paper-manufacturing industry, for example, the production facility needs much energy including electric and heat energy. So, in this paper, we chose a process in the model plant to calculate energy efficiency. To the Electric facilities, We calculated the energy efficiency of electric facilities by means of load factor and voltage unbalance of the motors. And to the heat energy, we calculated the heat energy efficiency by comparing necessary calorie and supplied calorie for the process. We performed all these energy efficiency calculations by using the measured data of a process in an operating plant.

Determination of Damping Modification Factor in RC Structures Due to Energy Absorption Efficiency (에너지 흡수효율에 의한 철근콘크리트 구조물의 감쇠비 수정계수 결정)

  • 김장훈;좌동훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.161-166
    • /
    • 2002
  • The modification factor( k-factor) of equivalent damping ratio utilized in the current state-of-the-practice to account for the imperfection of reinforced concrete structures in hysteresis loop is investigated. From this, it is found that the current modification factor does not include the effect of cyclic loading, one of the important characteristic properties of earthquake loading. This could be taken into account by considering the energy absorption efficiency based on the cummulative plastic deformation. From the study, it is suggested that the current approach for the modification factor for the equivalent damping ratio should be reformed.

  • PDF

The effect on the seasonal performance of an inverter compressor with higher and lower operating range (인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향)

  • 박윤철;하도용;민만기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

Regional Total Factor Energy Efficiency and its Determinants of the Korean Manufacturing Sector (우리나라 16개 시·도의 제조업부문 총요소 에너지 효율성 및 결정요인 분석)

  • Park, Changsuh;Seo, Yun Seok
    • Journal of the Korean Regional Science Association
    • /
    • v.33 no.1
    • /
    • pp.3-16
    • /
    • 2017
  • This paper analyzed 16 regional total factor energy efficiency (TFEE) of the Korean manufacturing sector using data envelopment analysis method for the period of 2005-2013. According to the empirical results, it is necessary to use TFEE as well as partial energy efficiency defined by the ratio of energy usage to output (energy intensity) when we compare energy efficiency. Secondly, TFEE in the Korean manufacturing sector is quite different across 16 regions. For example, Gangwon province should improve energy efficiency by 55% compared to Seoul, Gwangju, Ulsan, and Gyeongbuk which are located on production frontier. Furthermore, the estimation of panel tobit regression model showed that the higher non fossil fuel using, the higher production share of large-sized firms, the lower energy intensity, and the lower capital-labor ratio could have positive effect on TFEE.

Analysis of TV Standby Power for Development of Energy Efficiency Standard (TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석)

  • Kim, Ik-Pyo;Ro, Kyoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.