동일 체적의 건물 형상에 따른 에너지 소비량 패턴에 대한 분석 연구 (A Study on the Analysis of Energy Consumption Patterns According to the Building Shapes with the Same Volume)

  • 최원기;김헌중;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.103-109
    • /
    • 2007
  • This study was focused on the establishment of a fundamental DB(database) that is available in the building design process, so we performed the simulation analysis about the energy consumption on the various same volume buildings. Because energy consumption in building is affected by the exterior surface area, the ratio of long/short length in surface and the adjacent internal surface area etc.. For these purpose, we assumed the unit module and made a constructable 16 model buildings which are composed of the 16 unit modules. Then we analyzed the simulation using the TRNSYS 16 and the Seoul weather data. In results, energy consumption in building is more reduced that in case of the smaller exterior surface area, the lower stories building and the larger adjacent surface area etc.. Further study is to be required the sensitivity analysis on the various weather conditions, building shapes and window area etc..

도시계획단계의 에너지 수요예측 방안에 관한 연구 (A Study on Urban Energy Consumption Estimation on the Urban Planning Stage)

  • 여인애;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2012
  • This study suggested an improved algorithm of urban energy consumption estimation on the urban planning stage which concerns calculation accuracy. The results are as follows. (1) Urban energy consumption was estimated and managed per unit space using E-GIS DB which contains facility information per mesh. (2) Urban energy consumption was reflected by the urban facility classified and standardized by the characteristics of energy use. (3) Calculation accuracy of energy consumption was approached by separately suggested as summer algorithm reflecting urban heat island on summer energy use and winter algorithm reflecting heating system normally used in Korea.

  • PDF

연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석 (Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building)

  • 김성실;김영일
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

종합대학의 전력에너지 부하 특성에 관한 연구 (A Study on the Characteristics of Electric Power Consumption of University)

  • 이춘미;김주영;홍원화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.336-341
    • /
    • 2008
  • For the last half a century, Korea has been experienced rapid economic growth and industrialization development, however they cause serious problems that environment pollution and energy shortage are appeared, and the biggest problem that we are now confronted are required solutions through all over the world. Now, Korea's energy consumption is the 10th in the whole world. Among them, energy for buildings, about 25% in the whole Energy which spend in Korea, is very serious. Especially, the energy consumption of school buildings which have heating & cooling system according to improvements of educational environment are rapidly increasing. These features are explicit in the University, Because it has lots of colleges and facilities for lecture, experiment, and research. Especially, electric power consumption account for 75 percent of energy consumption in educational institutions. Accordingly, it is important to understand and analyze the pattern of electricity energy consumption which is used. This study attempts to appoint the place which is one of university and to investigate the characteristics of energy consumption like electricity, gas, oil.

  • PDF

인공지능 기반 에너지 효율화 방안 연구: 혼합적 연구방법론 중심으로 (A Study on Energy Efficiency Plan based on Artificial Intelligence: Focusing on Mixed Research Methodology)

  • 이문범;마태영
    • 한국IT서비스학회지
    • /
    • 제21권5호
    • /
    • pp.81-94
    • /
    • 2022
  • This study sets the research goal of reducing energy consumption which 'H' University Industry-University Cooperation Foundation and resident companies are concerned with, as well as conducting policy research and data analysis. We tried to present a solution to the problem using the technique. The algorithm showing the greatest reliability in the power of the model for the analysis algorithm of this paper was selected, and the power consumption trend curves per minute and hour were confirmed through predictive analysis while applying the algorithm, as well as confirming the singularity of excessive energy consumption. Through an additional sub-sensor analysis, the singularity of energy consumption of the unit was identified more precisely in the facility rather than in the building unit. Through this, this paper presents a system building model for real-time monitoring of campus power usage, and expands the data center and model for implementation. Furthermore, by presenting the possibility of expanding the field through research on the integration of mobile applications and IoT hardware, this study will provide school authorities and resident companies with specific solutions necessary to continuously solve data-based field problems.

호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 - (Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status -)

  • 이준수;구충완
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2022
  • The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

친환경 농촌마을계획을 위한 재생에너지 활용방안 연구 - 태양에너지 자원분석 - (A Study on Application of New & Renewable Energy for Environmental-friendly Planning of Rural Villages - Analysis of Solar Energy Resources -)

  • 남상운;김대식
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.105-112
    • /
    • 2008
  • Solar energy, which is one of renewable energy, would be the most useful resources that can be applied to making energy recycling villages without using fossil energy. This study analyzed energy potential on solar energy considering weather condition in three traditional villages and compared with energy consumption surveyed. A photovoltaic system having 3.0kWp capacity of unit module can generate 182.5%, 96.1% and 170.9% of the yearly mean consumption of electric power in Makhyun, Boojang, and Soso, respectively. A flat-plate solar collector having $2.64m^2$ area of unit module can generate warm water of $142{\ell}$/day, $89{\ell}$/day, and $173{\ell}$/day, respectively in three study villages. In Makhyun and Soso, photovoltaic power and warm water produced by solar energy were sufficient to supply required amount of electric power and warm water. However, both electric power and warm water produced by unit solar module were not sufficient in Boojang area, and so it is required to increase the module area by more than 50%. According to the results of this study, the appropriate combination of energy resources can be applied to rural green-village planning if the characteristic of energy potential for each local area is considered.

건축공사 주요자재별 에너지소비량 및 CO2 배출 원단위 값 산출에 산업연관표 적용 적정성 검토 연구 -2005년, 2007년 산업연관표를 중심으로- (Application of Input-Output Table to Estimate of Amount of Energy Consumption and CO2 Emission Intensity in the Construction Materials -Focusing on Input-Output Tables Published in 2005, 2007-)

  • 정영철;김성은;장영준;김태희;김광희
    • 한국건축시공학회지
    • /
    • 제11권3호
    • /
    • pp.247-255
    • /
    • 2011
  • 한국은행에서 2000년도에 발행된 산업연관표를 적용한 주요 건축자재의 에너지소비량과 $CO_2$ 배출에 대한 원단위 DB는 있지만 2005년, 2007년에 발행된 산업연관표를 이용한 원단위 DB는 없는 실정이다. 본 연구에서는 최근에 발행된 2005년, 2007년도 산업연관표를 이용하여 주요 건축자재에서 발생되는 에너지소비량 및 $CO_2$ 배출 원단위 값을 산정하고자 한다. 주요 건축자재의 에너지소비량 및 $CO_2$ 배출원단위 산출을 위한 방법은 산업연관표를 이용한 DB 구축 방식을 바탕으로 산출하였으며, 건설현장에서 주로 사용되는 16가지의 건설자재는 선별하여 적용하였다. 기존 연구결과에서 제시한 2000년도 산업연관표를 적용하여 산출된 원단위 DB 값과 비교한 결과 근소한 차이를 보이고 있어 본 연구의 산출방법이 적정한 것으로 판단하였다. 2005년, 2007년도 산업연관표를 이용하여 산출한 에너지소비량과 $CO_2$ 배출 원단위 값은 감소세를 보이고 있는 것으로 나타났으며, 시멘트와 철근을 주원료로 하는 자재에서 가장 많은 에너지소비량 및 $CO_2$ 배출 원단위 값을 나타났다. 본 연구의 결과를 통해 국내 실정에 적합한 건설자재 생산단계에서 발생되는 환경부하의 간접적인 예측이 가능할 것으로 사료된다.

자가용전기설비의 전력원단위 향상을 위한 전력관리 방안 (Recommended Practice for the Improvement of the Unit Cost of Power Consumption in Non-utility Electrical Installation)

  • 김세동
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.235-240
    • /
    • 2000
  • This paper presents the reasonable method for electric power management through efficient use of electricity. With a rapid of national economics and living standard, electrical energy consumption markedly increased. Especially it is increased electrical energy consumption in commercial buildings and thus an energy conservation through efficient use of electricity became more important.