• 제목/요약/키워드: Energy Consumption Unit

검색결과 354건 처리시간 0.034초

Water Footprint 개념을 이용한 가전제품의 수자원 사용량 산정 (세탁기를 중심으로) (A Study on the Evaluation of Water Consumption in Electric Appliances using Water Footprint - Focusing on Washing Machine -)

  • 조현정;김우람;박지형;황용우
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, by using the Water footprint technique, the water consumption by washing machines, which holds higher ranks in using water than any other electric appliances, was analyzed during their life cycle. The life cycle is defined as raw materials production step, manufacturing step, and using step. In raw materials production step, Input materials were researched by using LCI DB(Life Cycle Inventory Database) and the water consumption was calculated with consideration of approximately 65% Input materials which were based weight. In manufacturing step, the water consumption was calculated by the amount of energy used in assembly factories and components subcontractors and emission factor of energy. In using step, referring to guidelines on carbon footprint labeling, the life cycle is applied as 5 years for a washing machine and 218 cycles for annual bounds of usage. The water and power consumption for operating was calculated by referring to posted materials on the manufacture's websites. The water consumption by nation unit was calculated with the result of water consumption by a unit of washing machine. As a result, it shows that water consumption per life cycle s 110,105 kg/unit. The water consumption of each step is 90,495 kg/unit for using, 18,603 kg for raw materials production and 1,006 kg/unit for manufacturing, which apparently shows that the using step consume the most water resource. The water consumption by nation unit is 371,269,584tons in total based on 2006, 83,385,649 tons in both steps of raw material production and manufacturing, and 287,883,935 tons in using step.

The Evaluation of Energy Efficiency of Apartment Units after Conversion of Balconies into an Integrated Part of Interior Living Space by Computing with ECO2 Software

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.11-16
    • /
    • 2016
  • Purpose: International efforts to save Earth's environment against global warming and environmental pollution have been made in many countries. Energy consumption of buildings has been continuously increasing, and it has been over 40% of total energy consumption in the world. Energy consumption of buildings in Korea reaches 24% of total energy consumption. So, Korea government has executed building energy rating systems to control energy consumption of buildings. Method: This study was carried out to evaluate the energy performance of apartment unit plans according to converting balconies into living areas. For the study, six types of input models were made. Two input models(SP1 and SP 2) were the standard units that balcony areas were not converted into living areas, and four ones(EP 1, EP 2, EP 3 and EP 4) were the extended unit plans that balcony areas were turned into living areas. All of them were simulated with ECO2 software to assess building energy efficiency. Result: According to the results, the energy performance of the EP 2 and EP 4 models were 21. 8% higher than SP 1 model and 9.2% higher than SP 2 model.

서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석 (A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul)

  • 김성범;오병칠;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석 (Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption)

  • 한방우;강지수;김학준;김용진;원효식
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

철골조와 벽식조 공동주택의 환경영향 비교 연구 (A Comparison of Embodied Energy and Environmental Impacts between the Steel-Structured and Wall-typed Apartment Housing)

  • 이강희
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.83-91
    • /
    • 2004
  • In a planning stage, the assessment system is required to select the proper alternative, reflected the environmental affects such as energy, $CO_2$ and $SO_x$. Unit of energy consumption, $CO_2$ emission and $SO_x$ emission among various assessment systems could be effectively utilized to select the better alternative among various building types. But researches for these areas has not been conducted systematically, but limitedly and sporadically. In this paper, it aimed at providing the unit of energy consumption, $CO_2$ emission and $SO_x$ emission to evaluate the environmental affects between the steel-structured apartment building and wall-typed apartment building. For this, the input-output analysis could be utilized in the construction stage with two-type apartment housing. This approach can be utilized to compare the various alternatives in aspect of the energy consumption and the environment affect, and to select the relatively better alternative. This study found that the unit of energy, $CO_2$ and $SO_x$ of the steel-structured apartment building is lower than that of the wall-typed building

철도와 도로 수송부문의 에너지 소비 및 온실가스 배출 원단위 분석 (An Analysis of Energy Consumption and GHG Emission per Unit of Rail and Road Transportation)

  • 김병관;이진선;김현구;이재영
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.216-222
    • /
    • 2014
  • 일반적으로 철도는 환경적 측면에서 대단히 우수한 수단이며 도로보다 환경적으로 우위성을 갖고 있다고 인식되어왔다. 하지만 아직 우리나라에서는 철도의 환경적 우위성에 대하여 대부분 외국 사례를 인용하여 온 것이 대부분이며 우리의 자료를 바탕으로 정량적으로 분석한 연구가 부족한 것이 현실이다. 이에 본 연구에서는 철도는 철도통계연보와 한국철도공사의 전기업무자료를, 도로는 에너지 총조사보고서를 활동도 자료로 이용하여 여객과 화물의 에너지 소비량을 산정하고 IPCC 2006 가이드라인을 적용하여 Tier1 수준의 온실가스 배출량을 산정하였다. 최종적으로 환경적 영향을 파악하기 위한 차종별로 여객과 화물의 에너지 소비 및 온실가스 배출 원단위를 산정하여 보았다. 또한 철도와 도로 여객수송의 대표적인 수단으로 고속철도와 승용차의 산정결과를 비교하여 보았다.

농촌지역 농가 에너지소비 모델 개발 (Developing an Energy Consumption Model of Household Unit in Rural Area)

  • 리신호;왕군;윤성수
    • 한국농공학회논문집
    • /
    • 제50권4호
    • /
    • pp.99-109
    • /
    • 2008
  • As the price of traditional fossil fuels continue to increase, more people attach importance to the pollution of the environment caused by fossil fuel's burning, developing and using renewable energy resources has become a very important project all over the world. Also, the rural energy planning which is another method to improve energy utilization ratio and reduce environment pollution, is also regarded as a very effective way to reduce the energy consumption. There is a quantity of renewable energy resources and natural tribes in rural area, which is both feasible to develop the renewable energy and the regional energy planning. To carry out this, it is needs to know the area's quantity of renewable energy resources and the total energy consumption. This paper is to find out the relationship between rural energy consumption and rural conditions, and to found a energy consumption model which can conjecture the energy consumption in rural family. and the cost of rural family's energy consumption was founded to conjecture how much money dose it cost in rural family's energy consumption. The energy consumption model was concluded using the surveys of 76 families in 14 villages at the area of Chungcheongbuk-Do(province). The main factors to energy consumption was selected out which were number of family members, acreage of house, acreage of farmland and family's annual income.

공동주택 에너지 소비 경향 분석에 관한 연구 (The Analysis of Energy Consumption Characteristics of the Apartment)

  • 이현정;박선효;배상환;이병석;김양섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.305-310
    • /
    • 2012
  • In 2009, The Ministry of Land, Transport and Maritime Affairs, Korea opens apartment maintenance fee to public in "Apartment Management Info System". The high energy consumption component of apartment, which is hot water, water, electricity and heating, is released to public on this system. Through this system, apartment energy consumption and greenhouse gas emissions data can be compiled and expected to be accurately analyzed. Energy consumption and greenhouse gas emissions statistics of the apartment are collected being made to reduce energy and gas emissions. However, The accurate survey of energy consumption trends have not been accomplished. The energy consumption and greenhouse gas emissions survey in Apartment should be made first in order to reduce energy consumption. and then the correlation factors analysis which is affecting energy consumption is required. The purpose of this study is to analyze energy consumption characteristics of apartment in Bundann-gu, Seongnam, Korea in monthly, unit area and building built year basis. And then the research can be used as the basis of policy to Reduce energy consumption and greenhouse gas emissions.

  • PDF

대구시 공공건축물의 에너지 소비 원단위에 관한 연구 (An Analysis on the Energy Consumption Unit of the Public buildings in Daegu)

  • 최정희;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

고등학교 시설의 에너지 소비량특성에 관한 사례분석 (A Case Study of Characteristics of Energy Consumption of a High School Education Facilities)

  • 김강식;박재완;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.99-104
    • /
    • 2011
  • It has to take quantitative energy usage of high school education facilities in nations to set goals of their energy reduction. Therefore, The purpose of this study is to present various analysis result of energy consumption that is a statistic alanalysis of high school education facilities in Korea to set the goal of energy saving. This study has enforced analysis and has provided used energy for the year 2008 and general information from 2022 high school education facilities in 16 cities in South Korea by the relevant agency. Used energy sources in high school education facilities are electricity, gas for heating, oil, coal, water, and this study has changed the various used energy sources as unit 'kWh' only for comparison and analysis them.