• 제목/요약/키워드: Energy Consumption Rate

검색결과 1,027건 처리시간 0.024초

건물의 열성능 평가 지표에 관한 연구 (A Study of Thermal Performance Evaluation Index for Building)

  • 김미현;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.67-75
    • /
    • 2007
  • This study intends to the adequacy inspection of the room temperature variation rate that is available in the building heat performance evaluation index, so we performed the sensitivity analysis about the room temperature variation rate and the energy consumption in the room. For these purpose, we supposed the models which are composed of the various window area, insulation thickness and ventilation rate. Then we analyzed the simulation using the ESP-r and Seoul weather data. In this research, the pattern of the increasing & decreasing rate of annual load according to the change of the various design factors is similar to the pattern of increasing & decreasing rate of not the K-values but the room temperature variation rate. Also we derive the optimum value of the various design factors and the room temperature variation rate in this analysis model. Further study is to be required the development of convenient tool to use in the real design.

차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가 (The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio)

  • 장철용;한혜심;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

트위스트 운동 시 성별에 따른 심박수와 에너지 소모량의 비교 (The Comparison of Heart Rate and Energy Expenditure between Male and Female During Twist Exercise)

  • 전병환
    • 수산해양교육연구
    • /
    • 제27권1호
    • /
    • pp.243-252
    • /
    • 2015
  • The present study, to examine the effect of the exercise for weight control, compares the difference of the heart rate and energy expenditure by sex during Twist exercise. Twenty eight adults (male 14, female 14) were carried out Twist exercise for 7 minutes and 14 minutes. During performing the exercise program, to perform HR and related variables were measured for 7 minutes and 14 minutes. Through a twist exercise treatment and the following results were obtained. 1. Females had slightly higher, without statistical significance, number of heart beat, minimum heart rate, maximum heart rate, and average heart rate than male had for both 7 minutes and 14 minutes of Twist exercise. 2. In the case of energy consumption, significant differences did not appear until 7 minutes to perform Twist exercise. On the other hand, the energy consumption for 14 minutes of performance was significantly higher in male than in female (p<.05). However, energy expenditure for the period per minute per unit weight (kcal/min/kg) showed no difference. 3. If more than 30 minutes duration were preformed the Twist exercise, males were expected to consume significantly higher than females (p<.05). To consume calories for the 10,000 step walk of, it would be required about 76 minutes for Twist exercise time without distinction of sex. Through the above findings, twist exercise is a form of aerobic exercise for obesity prevention and weight control, as well as it might be beneficial to practice and maintain the health and physical fitness with offering a variety of exercise opportunities in the public.

VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어 (Effective Control of Indoor Air Pollutant using VAV/BPFS)

  • 최성우
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

가압탱크를 이용한 급수시스템의 해석 및 최적화 연구 (An Analysis of the Water Supply System with Pressurizing Tank)

  • 이태원;김태형;최도혁;김세동;김종필
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

무선랜에서 에너지 효율적인 전송 대역폭 결정 기법 (Energy-Efficient Transmission Bandwidth Adaptation in IEEE 802.11 WLANs)

  • 황환웅;윤지훈
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.651-657
    • /
    • 2018
  • IEEE 802.11 무선랜은 20MHz부터 160MHz의 전송 대역폭을 지원한다. 일반적으로 전송 시 대역폭이 증가함에 따라 전송속도가 증가하지만, 동시에 단위 주파수당 전송파워가 낮아져 오류율이 증가하고 재전송을 유발할 수 있다. 본 논문에서는 이러한 현상이 전송 에너지 소비에 미치는 영향을 분석하기 위한 수학적 모델링을 수행한다. 그리고, 이를 바탕으로 전송 대역폭을 결정하는 기법을 제시한다. 제시된 기법은 기존 전송 결과를 기반으로 대역폭별 오류율을 추정하고 이를 바탕으로 대역폭별 에너지 소비 테이블을 업데이트 후 이들 간의 비교를 통해 최적 대역폭을 결정한다. VoIP 트래픽을 가정한 시뮬레이션을 통해 다양한 환경에서 제안한 기법의 에너지 소비 성능을 평가한다.

대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석 (The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings)

  • 김병수;길영욱;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • 대형병원의 에너지 소비패턴을 분석한 후 마이크로가스터빈을 적용할 경우 기존 시스템 대비 냉난방에너지 절감량 및 전기에너지 절감량과 경제성분석을 통해 대형병원의 에너지 소비량을 절감하기 위한 에너지성능평가 모의연구를 수행하였다. 0.5[MW]급 마이크로 가스터빈을 설치한 후 에너지 성능분석을 한 결과 터빈에서의 발전효율은 30[%]이며, 전기는 건물에서 사용되는 조명에너지 뿐만 아니라 전체 전기에너지의 40[%]을 절감할 수 있는 것으로 분석되었다. 또한 터빈에서 발전되는 전기량과 배열을 냉난방에너지원으로 이용할 경우 전체 시스템효율은 70[%]로 상승할 뿐만 아니라 난방에너지의 56[%], 냉방에너지의 67[%]를 절감할 수 있는 것으로 분석되었으며 현가등가법에 의한 시스템 투자회수 기간이 약 9년으로 분석되었다.

히트펌프에 연계된 공기-물 직접접촉식 열교환기의 성능 (Performance of Air-Water Direct Contact Heat Exchanger Linked to Heat Pump)

  • 김영화;금동혁;유영선;강연구;김종구;장재경;이형모
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.80.2-80.2
    • /
    • 2011
  • Fossil fuel was a major energy resource but the consumption of fossil fuel will decrease gradually because of limited deposits and non-environmental features. In contrast, because the renewable energy resources are infinite and sustainable, their consumption has increased annually. To promote the supply of these infinite natural energy we have to develop more efficient and inexpensive heat recovery system. In this study a simple device was designed as a heat exchanger, that is a direct contact heat exchanger. This heat exchanger was manufactured in cylindrical shape with height of 1,500 mm and diameter of 1,000 mm. To test the efficiency of this heat exchanger, it was connected to the evaporator of heat pump system. During the experimental tests, the humid air of $10{\sim}30^{\circ}C$ was supplied to this air-to-water heat exchanger and then the water flow rate was set to 2500~3500 L/h. Heat recovery rate of this heat exchanger increased in proportion to entering air temperature and water flow rate.

  • PDF

정량화 시뮬레이션 모델을 활용한 단계적인 건축물에너지효율등급 향상 방안 (Stepwise Technique for Improving Building Energy Efficiency Rating Utilizing Quantified Simulation Model)

  • 김기석;김유민;김종성;오세규
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.65-73
    • /
    • 2014
  • Due to the Climate change and resource shortage by global warming, various problems are rising and getting worse around the world. Many countries are doing the considerable efforts to reduce greenhouse gas emissions. The government of South Korea also plans to decrease greenhouse gas emission, the various pilot projects are underway, which includes obligation of energy efficiency 1st rating and greenhouse gas target management system of public buildings. In particular, luxurious government office buildings and energy-wasting public building have issued and emerged as a social problem. Energy efficiency improvement of the existing public office buildings are becoming an important issue recently. This study is proposed the step-by-step energy improvement model according to the building energy efficiency rate in order to reduce the energy consumption. To attain this end, I set up a base model by analyzing the current architectural conditions of the existing public office buildings and grasped the specific properties of building energy consumption through energy simulations. Furthermore, I suggested phased reduction prototypes for the reduction target of energy consumption by applying the methods of the zero energy building plan. This study is expecting that prototypes would give directions when it comes to planning the implementation policy of phased building plan factors, according the building energy consumption reduction goal in the existing public office buildings which are the subject of building energy target management system.