서울지역 사무소 건물의 환경부하에 관한 연구 (A study on the environmental load of office buildings in Seoul)

  • 이상형;이윤규;양관섭;안태경;이승언;박효순
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.244-249
    • /
    • 1999
  • This study is to examine the emission rate of $CO_2$gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$emission rate of 34 office buildings surveyed is 22.4kg-$c/m^2$.year, which consists of 17.5kg-$c/m^2$.year by consuming electricity, and 4.9kg-$c/m^2$.year by consuming natural gas. And the $CO_2$emission rate of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by heating load. It is also proposed that the $CO_2$emission rate of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

가정에서의 열에너지 관리 현황조사 연구 -서울 지역을 중심으로- (An Exploratory Study of Energy Consumption and Management in the Home)

  • 윤복자
    • 대한가정학회지
    • /
    • 제18권1호
    • /
    • pp.67-82
    • /
    • 1980
  • The objectives of the study were to determine 1) energy uses for residential requirements, 2) if energy consumption and adoption of energy conservation attitudes and practices vary with independent variables family size, stage of family life cycle, homemaker's level of education, income, heating system, and number of electrical household items, and 3) if there is a correlation between energy conservation attitudes and practices. Questionnaires were given to the randomly selected homemakers I Seoul in the summer (September, 1979) and the winter (February, 1980). Analysis of variance and correlation were used to analyzed the data which consisted of 537 usable responses of 895 returned in the summer and 554 responses of 794 returned in the winter. The results are as follows: 1) The order of consumption rate of the direct energy uses for residential requirements was found to be heating and air conditioning, cooking, refrigeration, T.V., lighting, and miscellaneous. 2) Energy consumption and adoption of energy conservation attitudes and practices were significantly related to family size, homemaker's level of education, and the stage of family life cycle. (1) Families of five members revealed higher scores in attitudes and practices than families less than five or more than six. (2) The higher the homemaker's level of education, the more energy consumption and the higher scores I attitudes and practices were found. (3) Families in the middle stage of family life cycle tend to use more energy than younger or older families, but their scores in attitudes and practices were high. 3) There was a significant correlation between energy conservation attitudes and practices. However, the scores of the conservation practices were not as good as the attitudes. It may be attributed to either a lack of knowledge and/or financial difficulties, or a dissonance between the concept and implementation of energy conservation. 4) Recommendations for the energy-saving and energy-related public policies are: (1) to use such human resources as attitudes, values, feelings of agreement, and cooperation, as well as nonhuman resources for the energy conservation, (2) to develop a educational program and a creative system I order to implement energy conservation programs, and (3) to consider direct as well as indirect energy uses I selecting goods and services.

  • PDF

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

A Novel WBAN MAC protocol with Improved Energy Consumption and Data Rate

  • Rezvani, Sanaz;Ghorashi, S. Ali
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권9호
    • /
    • pp.2302-2322
    • /
    • 2012
  • Wireless Body Area Networks (WBANs) are introduced as an enabling technology in tele-health for patient monitoring. Designing an efficient Medium Access Control (MAC) protocol is the main challenge in WBANs because of their various applications and strict requirements such as low level of energy consumption, low transmission delay, the wide range of data rates and prioritizing emergency data. In this paper, we propose a new MAC protocol to provide different requirements of WBANs targeted for medical applications. The proposed MAC provides an efficient emergency response mechanism by considering the correlation between medical signals. It also reduces the power consumption of nodes by minimizing contention access, reducing the probability of the collision and using an efficient synchronization algorithm. In addition, the proposed MAC protocol increases the data rate of the nodes by allocating the resources according to the condition of the network. Analytical and simulation results show that the proposed MAC protocol outperforms IEEE 802.15.4 MAC protocol in terms of power consumption level as well as the average response delay. Also, the comparison results of the proposed MAC with IEEE 802.15.6 MAC protocol show a tradeoff between average response delay and medical data rate.

실시간 운영체제를 위한 저전력 GUI 설계 및 구현 (Design and Implementation of Low-Power GUI for Real-Time Operating System)

  • 정재엽;이철훈
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.817-821
    • /
    • 2007
  • 제한된 배터리를 가지고 있는 내장형 시스템에서 전력을 최소화하여 제한된 전력을 오랫동안 사용하는 기술은 중요한 문제로 인식되어 왔다. 최근 내장형 시스템은 대형 TFT-LCD와 터치스크린을 장착하면서 그에 따른 전력소비가 더 증가하고 있다. 본 논문에서는 GUI에서 전력소모를 감소할 수 있는 방안인 프레임버퍼 모니터링을 연구하였다. 프레임버퍼 모니터링 기법은 화면의 퀄리티(Quality)를 보장하는 범위 내에서 Refresh-rate과 Backlight을 조절하여 LCD에서 전력 소모를 줄이는 방법이다.

  • PDF

에너지 성능지표 기계부문 항목에 따른 업무용 건물의 에너지 절감율 분석 (Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part)

  • 이호진;김서훈;정재욱;장철용;송규동
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.49-54
    • /
    • 2013
  • released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.

Experimental Study on Four Cation Exchange Membranes in Electrosynthesis of Ammonium Persulfate

  • Wang, Chao;Zhou, Junbo;Gao, Liping
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권1호
    • /
    • pp.37-43
    • /
    • 2018
  • In order to improve current efficiency and decrease energy consumption in the electrosynthesis of ammonium persulfate, electrolytic properties of four cation exchange membranes, namely, the $JCM-II^{(R)}$ membrane, $Nafion^{(R)}$ 324 membrane CMI-$7000^{(R)}$ membrane and a self-made perfluorosulfonic ion exchange membrane (PGN membrane) were investigated using a sintered platinized titanium anode and a Pb-Sb-Sn alloy cathode in a self-made electrolytic cell. The effect of cell voltage and electrolyte flow rate on the current efficiency and the energy consumption were investigated. The results indicated that the PGN membrane could improve current efficiency to 94.85% and decrease energy consumption to $1119kWh\;t^{-1}$ (energy consumption per ton of the ammonium persulfate generated) under the optimal operating conditions and the highest current efficiency of the $JCM-II^{(R)}$ membrane, $Nafion^{(R)}$ 324 membrane and CMI-$7000^{(R)}$ membrane were 80.73%, 77.76% and 73.22% with their lowest energy consumption of $1323kWh\;t^{-1}$, $1539kWh\;t^{-1}$ and $2256kWh\;t^{-1}$, respectively. The PGN membrane has the advantages of high current efficiency and energy power consumption and has sufficient mechanical strength with the reinforced mesh. Therefore the PGN membrane will has good value in popularization in the industrial electrosynthesis of ammonium persulfate in the future.

Effects of endurance training for 4weeks on resting metabolic rate and excess post-exercise oxygen consumption in mouse

  • Jeon, Yerim;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • 운동영양학회지
    • /
    • 제16권2호
    • /
    • pp.113-122
    • /
    • 2012
  • This study assessed the amount of energy consumed and fat deposition after endurance training in order to review the effect of 4-week endurance exercise on resting metabolic rate of a mouse during and after exercise and the effect of exercise. A total of 19 seven-week-old ICR male mice were used as the study subject. Those mice were divided into sedentary group (Sed) and trained group (Tr) after a week of environment adaption. The Tr group was trained with endurance exercise five times a week for four weeks. Weight and the amount of food intake were daily weighed and resting metabolic rate and metabolic rate after exercise were assessed before starting exercise and on the fourth week after training. Metabolic rate during exercise were measured four weeks after training. At the end of breeding period, statistically significant difference was shown in weights of trained and sedentary groups (p < 0.05). During a resting period, no significant difference was shown in oxygen intake, respiratory exchange ratio, and the amount of carbohydrate and fat oxidized. Moreover, no significant difference was shown in excess post-exercise oxygen consumption (EPOC) of an hour period after training. In contrast, the maximal oxygen uptake (VO2 max) was approximately 11.1% higher in trained group after training compare to before. However, there was no significant difference in respiratory exchange ratio and carbohydrate and fat oxidization. During exercise, oxygen uptake, carbon dioxide production, and respiratory exchange ratio in energy metabolism during exercise showed no significant difference. However, significant difference was exhibited in the amount of fat oxidized in both groups. Summing up those results, endurance exercise could be concluded to be effective in weight control. However, weight loss is thought to be resulted from increase in fat oxidization during exercise unlike the conclusion made from previous studies where weight loss is prominently influenced by energy metabolism during a resting period and increased fat oxidation during post-exercise recovery. All experimental procedures were carried out at the Animal Experiment Research Center of Konkuk University. This study was conducted in accordance with the ethical guidelines of the Konkuk University Institutional Animal Care and Use Committee.

실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토 (Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value)

  • 정재훈
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

인력물자취급시의 인체심리학적 최대허용중량의 생리학적 고찰 (Physiological Assessment of the Psychophysical Maximum Acceptable Weight of Load for Manual Materials Handling Tasks)

  • 정성학;김홍기
    • 대한인간공학회지
    • /
    • 제18권1호
    • /
    • pp.1-12
    • /
    • 1999
  • The objective of this study was to investigate the metabolic energy consumption rate of the psychophysical Maximum Acceptable Weight of Loads (MAWLs) for different manual materials handling tasks. Lifting activities with four different lifting frequencies (2, 5, 8, 11 lifts/min) for a lifting range (from floor to 76cm height) were studied. The oxygen consumption rate and heart rate were measured or recorded while subjects were lifting their MAWLs. It was found that the relationship between MAWL and frequency can be described best by the exponential function with the R-sq value 0.9865 for this study. Psychophysical MAWL decreased from 22.38 to 7.48 kg, while the oxygen consumption rate with the MAWL increased from 717.8 to $1114.7m{\ell}-O_2/min$ as the frequency increased from 2 to 11 lifts/min. Heart rate also increased from 104.5 to 120.7 bpm. The ratio of oxygen consumption for the MAWL to the Physical Work Capacity (PWC) ranged from 28 to 43%. The MAWLs were greater than or equal to the Maximum Permissible Limits (MPLs) when the frequencies were higher than 8 lifts/min. It seems that the MAWLs by psychophysical approach when the frequencies were higher than 8 lifts/min tend to be overestimated from the viewpoint of the physiological criterion of the oxygen consumption rates. From these findings it is suggested that the NIOSH Guideline should not be directly applied to Korean without reasonable modifications.

  • PDF