Design of Step-down DC-DC Converter using Switched-capacitor for Small-sized Electronics Equipment (소형 전자기기를 위한 스위치드 커패시터 방식의 강압형 DC-DC 변환기 설계)

  • Kwon, Bo-Min;Heo, Yun-Seok;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4984-4990
    • /
    • 2010
  • In this paper, a Step-down CMOS DC-DC Converter using low power switched capacitor method is designed in a 0.5 ${\mu}m$ technology for the integration of devices. Conventional DC-DC converter is used inductor that can store energy in a magnetic field but have low efficiency because power consumption is caused by magnetic flux. And there were problems with size, weight and price to integrate chip. In this paper, a proposed Inductorless step-down CMOS DC-DC converter of low power using SC method is designed in a 0.5um technology to solve these problems. Designed DC-DC converter have 96% power efficiency with 200kHz frequency by using cadence simulation.

Key Management Framework based on Double Hash Chain for Secure Smart Grid Environments (안전한 스마트 그리드 환경을 위한 이중 해쉬 체인 기반 키 관리 프레임워크)

  • Lee, Young-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2063-2072
    • /
    • 2013
  • Smart Grid is the next-generation intelligent power grid that maximizes energy efficiency with the convergence of IT technologies and the existing power grid. It enables consumers to check power rates in real time for active power consumption. It also enables suppliers to measure their expected power generation load, which stabilizes the operation of the power system. However, there are high possibility that various kinds of security threats such as data exposure, data theft, and privacy invasion may occur in interactive communication with intelligent devices. Therefore, to establish a secure environment for responding to such security threat with the smart grid, the key management technique, which is the core of the development of a security mechanism, is required. Using a hash chain, this paper suggests a group key management mechanism that is efficiently applicable to the smart grid environment with its hierarchical structure, and analyzes the security and efficiency of the suggested group key management framework.

Analysis Process based on Modify K-means for Efficiency Improvement of Electric Power Data Pattern Detection (전력데이터 패턴 추출의 효율성 향상을 위한 변형된 K-means 기반의 분석 프로세스)

  • Jung, Se Hoon;Shin, Chang Sun;Cho, Yong Yun;Park, Jang Woo;Park, Myung Hye;Kim, Young Hyun;Lee, Seung Bae;Sim, Chun Bo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.12
    • /
    • pp.1960-1969
    • /
    • 2017
  • There have been ongoing researches to identify and analyze the patterns of electric power IoT data inside sensor nodes to supplement the stable supply of power and the efficiency of energy consumption. This study set out to propose an analysis process for electric power IoT data with the K-means algorithm, which is an unsupervised learning technique rather than a supervised one. There are a couple of problems with the old K-means algorithm, and one of them is the selection of cluster number K in a heuristic or random method. That approach is proper for the age of standardized data. The investigator proposed an analysis process of selecting an automated cluster number K through principal component analysis and the space division of normal distribution and incorporated it into electric power IoT data. The performance evaluation results show that it recorded a higher level of performance than the old algorithm in the cluster classification and analysis of pitches and rolls included in the communication bodies of utility poles.

A Study on the Accumulation Phenomena of Oxidized Starch in White Water in Closed Fine Papermaking Process (Part 1) -Effect of Papermaking system closure- (백상지 공정 폐쇄화에 따른 백수 내 산화전분의 축적 현상에 관한 연구 (제1보) -공정 폐쇄화의 영향-)

  • Ahn, Hyun-Kyun;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.3
    • /
    • pp.15-34
    • /
    • 2004
  • Diverse benefits such as reduction of fresh water consumption and effluent discharge, efficient use of raw materials and energy savings can be obtained by papermaking system closure. Closure of papermaking processes, however, causes many problems including reduction of the efficiency of additives, decrease of retention and dewatering, felt plugging, poor Paper quality, generation of slime and odor, poor vacuum efficiency, etc, and it has been recognized that accumulation of Inorganic and organic substances in the process white water is the prime cause of these problems. Therefore, technological developments for preventing accumulation of these detrimental substances are urgently required for Implementing papermaking system closure. Understanding of the accumulation phenomena of the inorganic and organic substances in the papermaking process white water is prerequisite for papermaking system closure. In this study a process simulation method was used to analyze the accumulation phenomena of anionic starch In the process white water as the closure level of a fine paper making process is increased. A pilot paper machine was used as a model process. Starch adsorption and desorption models were developed based on the concept of starch adsorption ratio, which was not considered in previous studies. Steady state simulation studies were carried out based on this model using a commercial simulator. In steady state simulation, the variation of dissolved starch concentration in each process unit was monitored as a function of white water usage for wire shower. The result of the steady state simulation showed that dissolved starch concentration and its increase ratio in Process units increased as white water usage ratio for wire shower increased.

Evaluation on the Fuel Efficiency of Hi-Pass System (고속도로 하이패스 시스템의 연료감소효과 평가)

  • Lee, Seong-Kwan Mark;Lee, Ki-Young;Choi, Yoon-Hwan;Kwak, Jin-Ho;Sung, Ji-Na
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2010
  • Around a toll plaza, vehicles do such maneuvers as slow down, stop, and speed up to pay their tolls when they use ordinary toll gates. They can be expected more fuel consumptions compared to the vehicles which use the Hi-pass, a Korean type of Electronic Toll Collection System(ETCS). To measure the exact amount of difference between the two gas consumptions, we equipped a test vehicle with a measurement system and constructed a model toll gate on our test field. Through the field tests on fuel consumptions, we could confirm a 36.7 % of energy saving when the test car used the Hi-pass. Then we projected the result on the total traffic volumes which had used national expressway network for five months from January 2009. Projected to the whole traffic, potential cost savings reached 5.34 billion won. We expect this result be frequently mentioned of to prove the fuel efficiency of the Hi-pass system.

The Hybrid Road Lighting Control System Design using Solar-Light Generation (태양광 발전을 이용한 하이브리드 도로조명 점등제어 시스템 설계)

  • Hong, Sung-Il;Lin, Chi-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.109-120
    • /
    • 2013
  • In this paper we proposed the design of the hybrid road lighting control system using solar-light generation. The proposed hybrid road lighting control system be power offer through hybrid controller using Solar-Light Generation, and it is designed so that it can control lighting up. To control supply of continuous power when during power shortages. And the gateway be transmit control command using zigbee to road lighting to ensure that automatic lighting control on human sensing. In this case, the gateway is apply the lighting control algorithm that decisions to the status of the system by a pre-set time schedule and be able to operate. In this paper, the proposed efficiency analysis results of a hybrid road lighting control system was consumed power of 129.6W per day, 3.8KW per month, 47.3KW per annual. As a result, it were able to increase the energy efficiency than existing lighting control system by reduce power consumption of 76.2% and the electricity prices of 76.8%.

Effects of Retention Time on the Simultaneous of Odor Removal and Sludge Solubilization Using a Non-Thermal Plasma System (저온 플라즈마와 활성슬러지 복합 공정에서 체류시간 변화가 악취 저감 및 슬러지 가용화에 미치는 영향)

  • NamGung, Hyeong-Gyu;Hwang, Hyun-Jung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.815-824
    • /
    • 2011
  • In this study, a non-thermal plasma system was employed to simultaneously remove odorous compounds and organic sludge. The system consisted of two reactors; the first one was the non-thermal plasma reactor where ozone was produced by the plasma reaction and the ozone oxidized hydrogen sulfide, the model odorous compound, and then the ozone-laden gas stream was introduced to the second reactor where wasted sludge was disintegrated and solubilized by ozone oxidation. In this study, the gas retention time (GRT) and the hydraulic retention time (HRT) were changed in the two-reactor system, and the effects of GRT and HRT on reduction efficiencies of odor and sludge were determined. As the GRT increased, the ozone concentration increased resulting in an increasing efficiency of hydrogen sulfide removal. However, the overall ozone loading rate to the second sludge reactor was the same at any GRT, which resulted in an insignificant change in sludge reduction rate. When HRTs in the sludge reactor were 1, 2, 4 hours, the sludge reduction rates were approximately 30% during the four-hour operation, while the rate increased to 70% at the HRT of 6 hours. Nevertheless, at HRTs greater than 4 hours, the solubilization efficiency was not proportionally increased with increasing specific input energy, indicating that an appropriate sludge retention time needs to be applied to achieve effective solubilization efficiencies at a minimal power consumption for the non-thermal plasma reaction.

PRODUCTION PERFORMANCE AND MILK PRODUCING EFFICIENCY IN DIFFERENT FILIAL GROUPS OF H. FRIESIAN × SAHIWAL HALFBREDS

  • Chaudhry, M.Z.;Tahir, M.J.;Rafique, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.3
    • /
    • pp.383-387
    • /
    • 1994
  • Six heifers each of $F_1$, $F_2$, $F_3$, $F_4$ H. Friesian $\times$ Sahjwal halfbreds and pure Sahiwal with overall average initial age and live weight of $315.6{\pm}134.8 days$ and $143.8{\pm}48.5kg$, respectively were used for this study. The under trial animals were fed according to N.R.C. (1978). The overall average age at maturity, first conception and first calving was $563.8{\pm}116.8$, $675.8{\pm}135.6$ and $956.8{\pm}149.8days$ with live weights as $302.2{\pm}58.6$, $342.6{\pm}41.5$ and $433.9{\pm}38.1kg$, respectively. The overall 305 days and total milk yield for 1st lactation was $2,729.0{\pm}669.3$ and $2,992.7{\pm}377.5litre$ while the FCM (at 4%) was $2,934.2{\pm}410.8litre$. The lactation length was $336.6{\pm}69.6days$. The fat and solids not fat contents were $4.5{\pm}0.2$ and $8.2{\pm}0.3percent$, respectively. The milk production in Sahiwal cows was significantly lower than crossbred cows. The services per conception were $2.5{\pm}1.3$. The overall per head per day consumption of DM, TCP and ME was $10.9{\pm}1.2kg$, $1,399{\pm}199gm$ and $22.6{\pm}2.4 M.Cal.$, respectively. The overall milk producing efficiency for the production of one litre of FCM was $1.12{\pm}0.15kg$ of DM, $142.2{\pm}17.76gm$ of TCP and $2.31{\pm}0.27M.Cal.$ of energy while the feeding cost was Rs. $1.46{\pm}0.22$ per litre of FCM produced. The feeding cost per litre FCM was significantly higher in Sahiwal and $F_2$ than in other genetic groups.

Effects of Volute Throat Enlargement and Fluid Viscosity on the Performance of an Over Hung Centrifugal Pump

  • Khoeini, Davood;Riasi, Alireza;Shahmoradi, Ali
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.30-39
    • /
    • 2017
  • In the current study, identifying regimes and behaviors of the various viscous fluids in a typical horizontal single-stage centrifugal pump and improving its performance by enhancing volute throat area have been surveyed numerically and experimentally. Indeed the initial pump had insufficient head at BEP (Best Efficient Point) in relevant applications. In order to solve this problem, the method of increasing the volute throat area on the prototype was used in steps and eventually the increased head values have been achieved. Then modified centrifugal pump, that has been constructed based on the modified control volume from numerical results, has been tested thoroughly. The maximum head and efficiency discrepancy between numerical and experimental results in BEP were 1.4 and 2.6% respectively. The effects of viscous fluids, from 1 cSt to 500 cSt, on the performance curves of centrifugal pump have been investigated as well and results showed that viscous fluids has significant effect on them. Indeed the highest head and efficiency in the same conditions at BEP has been obtained in viscosity 1 cst which was by 19.2% and 44% greater than the viscosity 500 cSt. It is also found that the highest viscous fluid had the highest energy consumption as the absorbed power of highest viscous fluid, 500 cSt, increased up to approximately 55% above the lowest viscous fluid, 1 cSt, values.

A Study of Extracting Appropriate Conditions for Efficient Desalination for the Underwater Archaeological Ceramics from Ma Island in Taean (태안 마도출토 도자기의 효율적 탈염처리를 위한 조건도출 연구)

  • Nam, Byeong-Jik;Park, Dae-Woo;Kang, Hyun-Mi;Jang, Sung-Yoon;Jung, Yong-Hwa
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.133-142
    • /
    • 2010
  • This paper focused on desalination method for the underwater archaeological ceramics. The desalination method applied in this study takes additional conditions such as the amount of desalting water, temperature, and agitation conditions and compares the effects of desalt process. The result of efficiency rate appears that the twenty-times of the object weight of desalting water is more effective than that of ten-times one, but shows less economic compared to the cost. In addition, the research shows that the efficiency rate has been improved around 20 to 30 %, yet such improvement is not taken into account as an effective result considering the risk of damage from the physical and chemical impact and the consumption of energy in applying additional method.