• Title/Summary/Keyword: Energy Coefficient

Search Result 2,859, Processing Time 0.032 seconds

On the Transmission Loss Measurement System (전달손실계수 측정 시스템에 대하여)

  • Ryu, Yun-Seon;Kim, Yoon-Seok;Callec, Philippe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.166-171
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Parametric study on equivalent damping ratio of different composite structural building systems

  • Farghaly, Ahmed Abdelraheem
    • Steel and Composite Structures
    • /
    • v.14 no.4
    • /
    • pp.349-365
    • /
    • 2013
  • Structures consisting of concrete and steel parts, which are irregular in damping ratios are investigated. This investigation is a code-based seismic design of such structures. Several practical difficulties encountered, due to inherent differences in the nature of dynamic response of each part, and the different damping ratios of the two parts. These structures are irregular in damping ratios and have complex modes of vibration so that their analysis cannot be handled with the readily available commercial software. Therefore, this work aims to provide simple yet sufficiently accurate constant values of equivalent damping ratios applied to the whole structure for handling the damping irregularity of such structures. The results show that the equivalent damping ratio changes with the height of the building and the kind of the structural system, but it is constant for all accelerations values. Thus, available software SAP2000 applied for seismic analysis, design and the provisions of existing seismic codes. Finally, evaluation of different kinds of structural system used in this research to find the most energy dissipating one found by finding the best value of quality coefficient.

Note on the Two-Microphone Methods for the Measurement of Acoustic Impedance (음향 임피던스 측정을 위한 이중 마이크로폰 기법에 대한 고찰)

  • SEO, SEONGHYEON
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.2
    • /
    • pp.163-169
    • /
    • 2018
  • The present article discusses about the measurement techniques of acoustic impedance that becomes one of the important acoustic characteristics of various boundaries found inside of propulsion systems. Acoustic characteristics including acoustic impedance and reflection coefficient can be often assessed and estimated by use of the two-microphone method. Theoretical expressions of acoustic impedance and reflection coefficient measured in an impedance tube are presented for both cases with mean flow and without flow, and the practical application of the method through calibration is also provided. The acoustic impedance and the reflection coefficient are related with axial locations of microphones, thermodynamic characteristics of gas inside, and the transfer function between the pressure wave measurements at multiple locations.

On the Transmission Loss Measurement System (전달손실계수 측정시스템에 대하여)

  • Yunseon RYU;Yoon-Seok KIM;Philippe CALLEC
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.323.1-323
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system usiong 4-microphone impedance tube is proposed, based on the idea calculating the full transger matrix of the acoustical sample to test. The theoretical backgroung and measurement system are introduced, and finally the measurement results are verified.

  • PDF

On the Transmission Loss Measurement System(Part II) (전달손실계수 측정 시스템에 대하여(Part II))

  • 김윤석;류윤선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.658-661
    • /
    • 2003
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

The Measurement of Diffusion Coefficient of Fission Gases in Urania with Respect to O/M Ratio (화학당량에 따른 우라니아의 핵분열 기체 확산 계수 측정)

  • 김희문;박광헌;김봉구;주용선;김건식;송근우;홍권표;강영환
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.1
    • /
    • pp.99-107
    • /
    • 2003
  • The diffusion coefficient of Xe-133 was obtained from an annealing test. The specimens were made from a UO$_2$ single crystal powder with natural enrichment. Weight and grain size were 300mg and ($23\mu\textrm{m}$, respectively. Oxygen potentials were obtained from an oxygen sensor. Released fractions were obtained from both results of gamma scans and quantitative analysis with MCNP code, The annealing test was performed at three temperatures at once. Diffusion coefficients of Xe-133 were calculated using slope of Booth theory in each O/M ratios. Activation energy and the pre-exponential factor of the diffusion coefficient were obtained. The activation energy of near stoichiomeric $UO_2$ is 310 kJ/mol. The measured values of near stoichiometric $UO_2$ are very close to other data available. Diffusion coefficients increase with hyper-stoichiometry, due to higher concentration of cation vacancies.

Influence of structure coupling effect on damping coefficient of offshore wind turbine blades

  • Zhang, Jianping;Gong, Zhen;Li, Haolin;Wang, Mingqiang;Zhang, Zhiwei;Shi, Fengfeng
    • Wind and Structures
    • /
    • v.29 no.6
    • /
    • pp.431-440
    • /
    • 2019
  • The aim of this study was to explore the influence of structure coupling effect on structural damping of blade based on the blade vibration characteristic. For this purpose, the scaled blade model of NREL 5 MW offshore wind turbine was processed and employed in the wind tunnel test to validate the reliability of theoretical and numerical models. The attenuation curves of maximum displacement and the varying curves of equivalent damping coefficient of the blade under the rated condition were respectively compared and analyzed by constructing single blade model and whole machine model. The attenuation law of blade dynamic response was obtained and the structure coupling effect was proved to exert a significant influence on the equivalent damping coefficient. The results indicate that the attenuation trend of the maximum displacement response curve of the single blade varies more obviously with the increase of elastic modulus as compared to that under the structure coupling effect. In contrast to the single blade model, the varying curve of equivalent damping coefficient with the period is relatively steep for the whole machine model. The findings are of great significance to guide the structure design and material selection for wind turbine blades.

Assessment of Physical Activity Pattern, Activity Coefficient, Basal Metabolic Rate and Daily Energy Expenditure in Female University Students (일부 여대생의 활동에너지 소비패턴, 활동계수, 기초대사량 및 에너지 소비량 평가)

  • Park, Yoonji;Kim, Jung Hee
    • Korean Journal of Community Nutrition
    • /
    • v.18 no.1
    • /
    • pp.45-54
    • /
    • 2013
  • This study was conducted to investigate the physical activity pattern, activity coefficient, basal metabolic rate and energy expenditure of female university students. One-day activity diaries were collected from 95 female university students in Seoul. Body composition was measured by Inbody 720. Subjects spent 7 hr 8min on sleeping, 6 hr 31min on studying, 2 hr 50min on physiological activity, 2 hr 3min on leisure, 2 hr 2min on walking and jogging, 1 hr 58 min on commuting and 22min on house chores. The activity coefficient of these subjects was 1.58. The comparison of body composition of subjects according to PAL showed that body weight, body fat mass, arm circumference and arm muscle circumference of physically active group were significantly higher than those of the sedentary group. BMR calculated by Harris-Benedict (H-B) formula and DRI formula and BMR measured by Inbody 720 was 1375 kcal, 1306 kcal and 1209 kcal, respectively. Total energy expenditure (TEE) examined by one-day activity diaries and calculated by H-B formula and estimated energy requirement (EER) formula in DRI was 2102.1 kcal, 2184.4 kcal, and 2164.5 kcal, respectively. The Pearson correlation coefficient between TEE examined by one-day activity diaries and H-B TEE was 0.795 (p < 0.001) while that between TEE examined and DRI EER was 0.604 (p < 0.001). Overall data indicated that female university students seemed to be less active. Therefore it is recommended that universities develop good exercise programs for their students. Further studies are needed to generate more meaningful results with a larger sample size and using machine attached to the body, which are able to detect physical activity more accurately.

Long-term Energy Demand Forecast in Korea Using Functional Principal Component Analysis (함수 주성분 분석을 이용한 한국의 장기 에너지 수요예측)

  • Choi, Yongok;Yang, Hyunjin
    • Environmental and Resource Economics Review
    • /
    • v.28 no.3
    • /
    • pp.437-465
    • /
    • 2019
  • In this study, we propose a new method to forecast long-term energy demand in Korea. Based on Chang et al. (2016), which models the time varying long-run relationship between electricity demand and GDP with a function coefficient panel model, we design several schemes to retain objectivity of the forecasting model. First, we select the bandwidth parameters for the income coefficient based on the out-of-sample forecasting performance. Second, we extend the income coefficient using the functional principal component analysis method. Third, we proposed a method to reflect the elasticity change patterns inherent in Korea. In the empirical analysis part, we forecasts the long-term energy demand in Korea using the proposed method to show that the proposed method generates more stable long term forecasts than the existing methods.

Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient (타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향)

  • Yoon, Jaedong;Lee, Younghoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.