• 제목/요약/키워드: Energy Block

검색결과 793건 처리시간 0.033초

고무 블록의 마찰 거동 해석 (Analysis of the Frictional Behavior of Rubber Block)

  • 김두만;유현승
    • 한국항공운항학회지
    • /
    • 제14권3호
    • /
    • pp.16-22
    • /
    • 2006
  • The friction and wear of tire determined by frictional behavior of tire tread that translate driving force, cornering force and braking force between automobile and road as a result of frictional behavior of each tread block. The tire tread block is representative case of rubber block doing frictional behavior. In this paper, frictional behavior of rubber block under compressive force and shear force was analytically obtained by using slip starting position parameter instead of friction coefficient which is uncertain to express exact value between rubber and other surfaces yet. And local coefficients of friction were calculated as a function of compressive force, shear force, shear modulus of rubber, shape factor and slip starting position.

  • PDF

모형실험을 통한 콘크리트 블록 및 시공이음부의 기밀성 측정 (Measurement of Air Tightness of Concrete Block and its Construction Joint from a Model Experiment)

  • 김형목;류동우;신중호;송원경
    • 터널과지하공간
    • /
    • 제20권6호
    • /
    • pp.434-445
    • /
    • 2010
  • 대용량 전력에너지저장시설로서의 복공식 압축공기 지하저장시설의 기밀시스템을 구성하는 콘크리트 라이닝 및 현장 타설 과정에서 발생하는 시공이음부의 투기특성을 파악하고자 콘크리트 블록시료를 이용한 모형실험을 수행하였다. 시공이음부의 투과계수는 콘크리트 블록보다 약 $10^1{\sim}10^4$ 배 정도의 투과성이 큰 것으로 파악되어, 현장 타설과정에서 시공이음부의 품질관리가 저장시설의 기밀성능 확보 관점에서 매우 중요함을 확인하였다. 또한, 접합면에 아크릴계 접착제를 타설함으로써 시공이음부의 투과계수를 콘크리트 블록 수준까지 감소시킬 수 있었으며 콘크리트 블록의 초기 수분함량이 높을수록 투과계수가 감소하여 기밀성능을 향상시킬 수 있음을 확인하였다.

폴리(에틸렌 테레프탈레이트)/폴리(에틸렌 나프탈레이트) 공중합체의 유연기판 특성 (Characteristics of PET-PEN Copolymer as a Material for Flexible Substrate)

  • 염주선;김재현;강호종
    • 폴리머
    • /
    • 제35권6호
    • /
    • pp.599-604
    • /
    • 2011
  • 폴리에스테르 유연기판 제조를 위하여 PET-PEN 공중합체를 합성하고 이들의 형태학적 변화가 유연기판 특성에 미치는 영향을 살펴보았다. 합성된 PET-PEN 공중합체는 DMT/NDC의 조성비에 따라 공중합체 block sequence가 달라짐을 확인하였다. 공중합체에 PET-PEN과 PEN의 block sequence가 증가할수록 유리전이온도가 증가하며 이에 따라 유연기판의 치수안정성이 증가됨을 확인하였으며 DMT/NDC의 조성비가 50/50인 경우, 열팽창계수(CTE)가 최소가 됨을 확인하였다. 합성된 PET-PEN 공중합체는 광투과 특성이 80% 이상을 유지하며 1시간 동안 $280^{\circ}C$에서의 열안정성도 0.4 wt% 이내를 유지하여 유연기판으로 적용이 가능함을 알 수 있었다.

3차원 레이저 각인으로 블록형 섬광체의 픽셀형화를 통한 민감도 향상 검출기 개발 (Development of Sensitivity-Enhanced Detector using Pixelization of Block Scintillator with 3D Laser Engraving)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.313-318
    • /
    • 2019
  • 민감도 향상을 위해 블록형 섬광체를 사용한 검출기를 개발하였다. 픽셀형 섬광체는 섬광체에서 발생된 빛을 최대한 광센서로 이동시키기 위해 픽셀 사이에 반사체가 위치하며, 반사체 부분으로 민감도 손실이 발생한다. 민감도를 향상시키고 픽셀형 섬광체의 특징을 가지게 하기 위해 블록형 섬광체를 레이저 각인을 통해 픽셀 형태의 섬광체로 가공하였다. 본 섬광체를 위치민감형 광전증배관과 결합하여 평면 영상을 획득하였고, 각 픽셀별 에너지 스펙트럼과, 에너지 분해능을 측정하였으며, GATE 시뮬레이션을 통해 블록형 섬광체와 픽셀 섬광체의 민감도 분석을 수행하였다. 측정된 전체 에너지 분해능은 20.7%를 보였으며, 민감도는 픽셀 섬광체에 비해 18.5% 높은 결과를 나타내었다. 본 검출기를 감마카메라 및 양전자방출단층촬영기기 등의 영상화 기기에 활용할 경우 높은 민감도 향상을 통해 촬영시간의 단축 및 적은 방사선원 사용으로 환자의 피폭선량 감소를 이룰 수 있을 것이다.

블럭이 부착된 수평 유로에서의 강제대류 열전달 해석 (Forced Convection Cooling Across Rectangular Blocks in a Parallel Channel)

  • 조한승;유재석
    • 에너지공학
    • /
    • 제2권3호
    • /
    • pp.251-257
    • /
    • 1993
  • 유한체적법(Finite Volume Method)을 이용하여 블럭이 부착된 수평 유로의 강제 대류 열전달 현상을 해석하였다. 블럭의 갯수, Reynolds 수 그리고 블럭 간의 간격을 변화시키면서 해석하였고 블럭이 부착된 수평판은 전도벽면 (conducting plate)으로 해석하였다. 블럭내에서는 1/2 체적과 전체적에서 열원이 있다고 가정하였으며, 유동은 2차원 정상상태 비압축성 유동이라고 하였다. 전체적에서 열원이 있는 경우보다 1/2 체적에서 열원이 있는 경우가 전체 온도값이 높게 나타났으며, Reynolds 수와 블럭 사이의 간격이 커질수록 온도값이 낮아진다. 수평판이 단열되어 있는 경우보다 전도벽면으로 해석한 경우가 온도값이 낮게 나타나며 수평판이 단옅되어 있다고 가정한 경우에는 최고온도 값의 위치가 단열면 근처이나 전도벽면의 경우에는 블럭내의 중심에서 우측으로 치우쳐 있다. 그리고, 블럭의 1/2 체적에서 열원이 있는 경우의 최고 온도 위치는 블럭의 전체적에서 열원이 있는 경우의 위치보다 더 상단에 치우침을 알 수 있다. Nusselt 수는 블럭 윗면의 좌측 부분에서 다른 부분보다 높은 수치를 나타내고 있으며 Reynolds 수가 커질수록 Nusselt 수의 값이 증가한다. 그리고, 블럭내의 최고 온도값은 이러한 무차원 변수들과의 상관 함수를 이용하여 예측하였다.

  • PDF

사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가 (Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer)

  • 박수진;정선영;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

Lifetime Evaluation of Digital Engineered Safety Features Actuation System Using Reliability Block Diagram

  • Park, Joo-Hyun;Lee, Dong-Young;Park, Jong-Gyun;Han, Jae-Bok;Jun Lyou
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2002년도 정기학술대회
    • /
    • pp.387-401
    • /
    • 2002
  • The Digital Engineered Safety Feature Actuation System (DESFAS) of nuclear power plants actuates safety systems to mitigate severe accidents occurred in nuclear power plants. The reliability of the system should be evaluated in order to meet the reliability criteria of nuclear power plants. In this work, we have calculated and evaluated the lifetime of DESFAS by using Reliability Block Diagram (RBD) and failure rates of digital control components. Surveillance test is assumed in the evaluation. The result shows that the digital control component can be used in DESFAS system.

  • PDF

모바일 사물인터넷 디바이스를 위한 에너지 효율적인 캐시 및 메모리 관리 기법 (Management Technique of Energy-Efficient Cache and Memory for Mobile IoT Devices)

  • 반효경
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.27-32
    • /
    • 2021
  • 본 논문은 차세대 사물인터넷 디바이스를 위한 에너지 효율적인 캐시 및 메모리 관리 기법을 제안한다. 제안하는 기법은 전력 소모가 적은 상변화 메모리를 사물인터넷 디바이스의 메인 메모리로 채택하고 캐시 메모리의 관리 시 쓰기 연산에 취약한 상변화 메모리의 쓰기량을 최소화하는 방향으로 설계한다. 구체적으로 살펴보면 최종단 캐시 메모리에서 캐시 블록이 삭제되어 메인 메모리로 반영될 때, 캐시 블록을 구성하는 캐시 라인별 수정 여부를 추적하여 상변화 메모리에 쓰기 발생량을 적게 발생시키는 캐시 블록을 우선적으로 교체한다. 또한, 최종단 캐시 메모리에서 캐시 블록의 참조 비트와 캐시 라인의 수정 비트를 함께 고려함으로써 메모리 시스템의 성능은 훼손하지 않으면서 에너지 소모를 줄이는 방식을 사용한다. 스펙 벤치마크를 이용한 시뮬레이션 실험을 통해 제안한 기법이 상변화 메모리에 발생하는 쓰기량을 평균 34.6% 줄이고 전력 소모를 28.9% 줄이면서 메모리의 성능 저하는 발생시키지 않음을 보인다.

연료전지용 양이온 전도성이 증가된 디페닐 단위를 갖는 블록공중합체 혼성막 제조 및 특성 (Preparation and Characterization of Hybrid Membrane for Block Copolymer Containing Diphenyl Unit Increasing Cationic Conductivity for Fuel Cells)

  • 김애란
    • 한국수소및신에너지학회논문집
    • /
    • 제28권5호
    • /
    • pp.465-470
    • /
    • 2017
  • Sulfonated fluorinated block copolymers having diphenyl units were mixed with the sulfonated cationic conductive polymers at an optimum mixing ratio to form hybrid membranes for fuel cells and their characteristics were studied. 2D and 3D AFM topology analysis confirmed that the number of hydrophilic units in the hybrid membrane was improved. Through the FE-SEM, the microstructure of the hybrid membrane implied hydrogen bonding and pi-pi interactions, and EDAX confirmed carbon, oxygen, sulfur, and fluorine. The thermogravimetric analysis showed that the hybrid membrane was thermally stable and the hydrophilicity of the hybrid membrane was increased by the contact angle of water droplets. As a result, it was confirmed that the cation conductivity increased by a factor of 1.8 times as the number of acidic domains in the hybrid film increased.

발열체가 있는 평행평판공간내의 대류열전달에 관한 수치해석 (A Study on Mixed Convection in Parallel Flat Plate with Heated Rectangular Block Arrays)

  • 정백영;이채문;임장순
    • 태양에너지
    • /
    • 제6권2호
    • /
    • pp.62-69
    • /
    • 1986
  • An analysis is made of the fully developed laminar flow and heat transfer in a parallel flat plate with heated rectangular block arrays to investigated the influence of bouyancy force. The shrouds is considered as adiabatic, while the heated block surface transmit a uniform rate of heat flux per unit axial length. The governing equations for velocity and temperature are solved by SIMPLE(Semi-Implicit Method Pressure Linked Equation) algorithm. Detailed velocity and temperature fields and overall heat transfer on wide range of Rayleigh number and various aspect ratios of heated rectangular blocks are computed. The result show that bouyancy leads to a significient enhancement in heat transfer along with a smaller increase in pressure drop, with the great enhancement found when the aspect ratio is 3.0.

  • PDF