• 제목/요약/키워드: Energy Block

검색결과 793건 처리시간 0.033초

블록 분류를 이용한 명함 영상에서의 블러링 판단 (Decision on Blurring for Business Card Images Using Block Classification)

  • 김종흔;장익훈;김남철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.1707-1710
    • /
    • 2003
  • In this paper, we propose a method of decision on blurring for business card images using block classification. In the proposed method, an input image is partitioned into 8${\times}$8 blocks and each block is classified into character block or background block using a block energy calculated in DCT domain. Whether the input image is blurring or non-blurring is determined using a ratio of low frequency energy and high frequency energy in DCT domain. Experimental results show that the proposed block classification classifies block well and the proposed decision on blurring decides well for various business card images.

  • PDF

하이브리드 에너지하베스팅 블록 개발 및 발전성능 평가 (Development of Hybrid Energy Harvesting Block and Evaluation on Power Generation Performance)

  • 김효진;박지영;진규남;노명현
    • 토지주택연구
    • /
    • 제5권2호
    • /
    • pp.99-106
    • /
    • 2014
  • 이 연구에서는 주택과 도시 시설물에 적용이 가능하고, 시설물의 수요특성에 적합한 맞춤형 하이브리드형 에너지블록을 압전과 전자기 유도방식을 동시에 활용하여 개발하고자 하였다. 이를 위하여 에너지하베스팅 블록의 종류별 특성과 요구조건을 분석하고 그에 따른 에너지블록의 개선방향 및 적용방안을 도출하였다. 이러한 방안에 따라 선행연구에서 개발된 프로토타입 에너지블록의 특성 및 성능과 이 연구에서 개발된 하이브리드 에너지블록과의 성능을 비교분석 하였다. 비교결과, 하이브리드 에너지 블록이 기존 프로토타입에 비하여 1회 가진 시 12.7배, 그리고 5회 연속가진 시 28.9배의 출력을 나타냈다. 이는 연구목적인 W급의 전기에너지 생산목적에 부합되는 것으로, 주택 및 도시시설물에 적용이 가능할 것으로 사료된다.

BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 - (Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories -)

  • 전재홍;박혜진;이권형;추승연
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

도시·주택 적용 에너지수확 블록구조의 진동 특성 및 발전성능 평가 (Evaluation on the Performance of Power Generation and Vibration Characteristics of Energy Harvesting Block Structures for Urban & Housing Application)

  • 노명현;이상열
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3735-3740
    • /
    • 2012
  • 본 연구는 다양한 에너지 하비스팅 기술들 중 압전 기술과 전자기 유도 방식을 조합한 에너지 블록 구조를 개발하고 발전성능 평가를 수행한다. 본 연구의 목적은 개발된 에너지 하비스팅 블록의 주택 도시 분야 적용성을 평가하기 위한 것이다. 본 연구는 동적 특성을 분석하기 위하여 유한요소 해석을 실시하고, 실험실 규모의 다층 에너지 하비스터의 현 발전수준을 평가하여 제시하였다. 그 다음으로 증폭기술이 적용된 프로토타입의 특징을 설명하고 개발된 프로토 타입 모듈의 발전성능을 다각적으로 평가하여 제시하였다.

크라우칭(Crouching) 스타트 시 뒤 블록 각도 변화에 따른 발목 관절의 기계적 에너지에 대한 연구 (A Study of the Ankle Joint to Mechanical Energy in Crouching Start According to the Backward Block Inclined Angle Increase)

  • 권문석;신성휴
    • 한국운동역학회지
    • /
    • 제15권1호
    • /
    • pp.19-28
    • /
    • 2005
  • The purpose of this study was to improve the ankle joint to mechanical energy in Crouching start according to the backward block inclined angle(F, F(+1), F(+2)) increase. For purpose of this study the ankle joint was considered as a single hinge joint rotation about a transverse axis. A two-dimensional(sagittal plane) analysis was performed on data collected from 3 spriters(university student). During Crouching start, the ankle joint moment showed a similar patterns according to the backward block inclined angle increase. The peak values of ankle joint moment was plantar flexion approximately 80% throughout the contact phase for Crouching start. The absorbed and generated energy represented different values from the backward block inclined angle increase at ankle joint. On the backward block inclined angle F, subject A($55^{\circ}$) and C($50^{\circ}$) Produced energy generation more than other block inclined angles. On the backward block inclined angle F(+2), subject B($50^{\circ}$) showed largest energy generation.

방사선으로 제조된 가교 구조의 Poly(Styrene-Butadiene-Styrene) 블록 공중합체 특성에 관한 연구 (Study on the Physicochemical Properties of Crosslinked Poly(Styrene-Butadiene-Styrene) Block Copolymers Prepared by Radiation)

  • 이선영;송주명;손준용;신준화
    • 방사선산업학회지
    • /
    • 제6권2호
    • /
    • pp.171-176
    • /
    • 2012
  • In this study, a crosslinked poly(styrene-butadiene-styrene) [SBS] block copolymers were prepared by using gamma ray irradiation method. The effects of various radiation doses on the degree of crosslinking, thermo property, and morphology of crosslinked SBS block copolymer were investigated. The degree of crosslinking of crosslinked SBS block copolymers were measured by gel-fraction and FT-IR. It was found that the degree of crosslinking of crosslinked SBS block copolymers increases with increase of the irradiation dose while the TGA result shows that the initial degradation temperature of irradiated SBS block copolymer was shifted to lower temperature with increasing irradiation dose. These results indicate that degradation reaction also occurs when SBS block copolymer is exposed to gamma ray irradiation for crosslinking reaction. The SAXS and FE-SEM results indicate that the phase separation of the styrene block and butadiene block was reduced with increasing irradiation dose.

고무 블록의 마찰에너지 해석 (An Analysis of the Frictional Energy on the Rubber Block)

  • 유현승;김두만;이상주;고범진
    • 한국항공우주학회지
    • /
    • 제35권7호
    • /
    • pp.619-626
    • /
    • 2007
  • 고무 블록의 마찰에너지에 관한 연구는 고무 마모 연구를 위한 기초 연구이자 마찰과 마모의 관계를 규정짓는 중요한 연구이며, 지금까지의 마모 이론은 대부분 마찰에너지에 근거하여 전개되어 오고 있다. 하지만, 대부분이 실험이나 유한요소 해석에 기초한 연구이며, 해석적 방법에 의한 연구는 많이 이루어지지 않았다. 따라서 본 논문에서는 에너지 방법을 이용하여 재료 물성, 블록의 형상, 수직 및 전단하중, 블록 이동 속도의 함수로 표현되는 마찰에너지를 해석적으로 구하고 그 결과를 시험 결과와 비교 검토하였으며, 이를 통해 마모 특성 해석의 정확도를 높일 수 있는 기반을 마련하였다

깍은 사면체형 소파블록의 안정성 평가 (Investigation of Statbility of Truncated Tetrahedron Type Amore Block)

  • 조홍동;배우석;김명균;이호진
    • 한국안전학회지
    • /
    • 제24권5호
    • /
    • pp.43-47
    • /
    • 2009
  • Armor block is used to reduce wave energy. To do this, the stability of coastal structure is enhanced. It is very expensive to develop a new type armor block. So, the research of new type armor block is very short. We develope truncated tetrahedron type armor block(new type block) which have a hole in center part. In this study, the stability of new type armor block is investigated by hydraulic model test. In the result, the stability coefficient($K_D$) of new type armor block is 11.8. this value is more superior than value of tetrapod.

도시·주택 적용 미관용 에너지 블록의 발전성능 평가 (Evaluation on the Performance of Power Generation of Energy Harvesting Blocks for Urban and Housing Application)

  • 노명현;김효진;박지영;이상열;조영봉
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.187-193
    • /
    • 2012
  • 최근 에너지 관련 연구분야에서 새롭게 주목받는 것이 주변의 에너지를 수확하는 에너지 하비스팅 기술이다. 본 논문에서는 다양한 에너지 하비스팅 기술들 중 압전 기술과 전자기 유도 방식을 조합한 에너지 블록의 발전성능이 조사되었다. 본 연구의 목적은 개발된 에너지 하비스팅 블록의 주택 도시 분야 적용성을 평가하기 위한 것이다. 이를 위해 본 논문에서는 실험실 규모의 다층 에너지 하비스터의 현 발전수준을 평가하여 제시하였다. 그 다음으로 증폭기술이 적용된 프로토타입의 특징을 설명하고 개발된 프로토타입 모듈의 발전성능을 다각적으로 평가하여 제시하였다. 성능 평가 결과, 개발된 에너지 블록은 기존 상용 제품에 비해서 255%와 505%까지 성능이 향상되었고 그 우수성이 입증되었다. 마지막으로 에너지 하비스팅 블록의 후속 연구 방향을 제시하였다.

고주파 에너지에 의한 가변블럭 변환 부호화법 (A variable block-size transform coding by high-frequency energy)

  • 곽내정;이승희;송영준;안재형
    • 한국통신학회논문지
    • /
    • 제21권5호
    • /
    • pp.1089-1095
    • /
    • 1996
  • 가변블록 변환부호화는 변환부호화에 적용되는 블럭의 크기를 다르게 하여 코딩의 효율을 좋게 한다. 변환블록의 크기는 블럭의 활성도에 따라 적응된다. 즉, 블럭의 활성도가 크면 블럭의 크기는 작아지고, 반대로 활성도가 작으면 블럭의 크기가 커진다. 본 논문에서는 블럭의 활성도로서 분산값 대신에 변환계수의 고주파 에너지를 이용하였다. 컴퓨터 시뮬레이션 결과, 제안한 방법이 분산값을 이용한 방법보다는 약 1~5dB, MAD를 이용한 방법보다는 약 0.5~3dB정도의 성능개선을 보여주었다.

  • PDF