• Title/Summary/Keyword: Energy Allocation

Search Result 361, Processing Time 0.085 seconds

Optimal Allocation of Shunt Capacitor-Reactor Bank in Distribution System with Dispersed Generators Considering Installation and Maintenance Cost (분산전원을 포함한 배전계통에서 설치비용과 유지보수 비용을 고려한 병렬 캐패시터-리액터 Bank의 최적 설치 위치 선정)

  • Heo, Jae-Haeng;Lyu, Jae-Kun;Lee, Woo-Ri;Park, Jong-Young;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1511-1519
    • /
    • 2013
  • This paper proposes the allocation method for capacitor-reactor banks in a distribution system with dispersed generators to reduce the installation costs, the maintenance costs and minimize the loss of electrical energy. The expected lifetime and maintenance period of devices with moving parts depends on the total number of operations, which affects the replacement and maintenance period for aging equipment under a limited budget. In this paper, the expected device lifetimes and the maintenance period are included in the formulation, and the optimal operation status of the devices is determined using a genetic algorithm. The optimal numbers and locations for capacitor-reactor banks are determined based on the optimal operation status. Simulation results in a 69-bus distribution system with the dispersed generator show that the proposed technique performs better than conventional methods.

Performance of Relay Networks with Partially Differential Modulation Scheme Depending on Energy Allocation in Railway Environments (철도환경에서 에너지 할당에 따른 부분차등변조 방식을 이용한 중계 네트워크의 성능)

  • Cho, Woong;Cho, Han-Byeog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.17-22
    • /
    • 2016
  • In relay networks, relay nodes amplify or demodulate/remodulate the received signal from the transmitter, and transmit that signal to the receiver. The received signals from several relays are combined and used for demodulation at the receiver, which enhances the performance of the overall system. Partially differential modulation scheme which uses coherent modulation at the relay and non-coherent modulation scheme at the receiver is adopted for modulation scheme. We analyze the performance of systems depending on various energy allocations of source and relays given the total energy in relay networks.

Energy efficiency task scheduling for battery level-aware mobile edge computing in heterogeneous networks

  • Xie, Zhigang;Song, Xin;Cao, Jing;Xu, Siyang
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.746-758
    • /
    • 2022
  • This paper focuses on a mobile edge-computing-enabled heterogeneous network. A battery level-aware task-scheduling framework is proposed to improve the energy efficiency and prolong the operating hours of battery-powered mobile devices. The formulated optimization problem is a typical mixed-integer nonlinear programming problem. To solve this nondeterministic polynomial (NP)-hard problem, a decomposition-based task-scheduling algorithm is proposed. Using an alternating optimization technology, the original problem is divided into three subproblems. In the outer loop, task offloading decisions are yielded using a pruning search algorithm for the task offloading subproblem. In the inner loop, closed-form solutions for computational resource allocation subproblems are derived using the Lagrangian multiplier method. Then, it is proven that the transmitted power-allocation subproblem is a unimodal problem; this subproblem is solved using a gradient-based bisection search algorithm. The simulation results demonstrate that the proposed framework achieves better energy efficiency than other frameworks. Additionally, the impact of the battery level-aware scheme on the operating hours of battery-powered mobile devices is also investigated.

A Simple Model for RAM Analysis and Its Application to DUPIC Fuel Fabrication Facility

  • Ko, Won-Il;Park, Jong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.505-510
    • /
    • 1996
  • A simple model for RAM (Reliability, Availability and Maintainability) analysis and its computer code are developed for application to DUPIC fuel fabrication system. The approach is obtained by linking the allocation model (top-down method) to bottom-up method for RAM analysis. As a result, the availability requirement of subsystem, as well as the buffer storage requirement between processes, are evaluated for the DUPIC facility..

  • PDF

An Analysis of Greenhouse Gas Emission and Role of Gas Generation in Electric Sector (발전부문 온실가스배출과 가스발전의 역할 분석)

  • Kang, Hee-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.11-16
    • /
    • 2006
  • The purposes of this study is to develop a domestic MARKAL(MARKet ALlocation) model with construction of database system to find the technology mix for the electricity generation market in Korea. The MARKAL model is officially used for national energy system optimization in the International Energy Agency(IEA), and the role is becoming more important in relation to analyze the greenhouse gas mitigation potential and to evaluate the technologies. Four scenarios specially emphasized on the greenhouse gas reduction and technology mix of electric generation were applied, each of them covering the analysis periods between 2004 and 2040.

  • PDF

An Adaptive-Harvest-Then-Transmit Protocol for Wireless Powered Communications: Multiple Antennas System and Performance Analysis

  • Nguyen, Xuan Xinh;Do, Dinh-Thuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.1889-1910
    • /
    • 2017
  • This paper investigates a protocol so-called Adaptive Harvest Then Transmit (AHTT) for wireless powered communication networks (WPCNs) in multiple-input single-output (MISO) downlink systems, which assists in transmitting signals from a multi-antenna transmitter to a single-antenna receiver. Particularly, the power constrained relay is supplied with power by utilizing radio frequency (RF) signals from the source. In order to take advantage of multiple antennas, two different linear processing schemes, including Maximum Ratio Combining (MRC) and Selection Combination (SC) are studied. The system outage capacity and ergodic capacity are evaluated for performance analysis. Furthermore, the optimal power allocation is also considered. Our numerical and simulation results prove that the implementation of multiple antennas helps boost the energy harvesting capability. Therefore, this paper puts forward a new way to the energy efficiency (EE) enhancement, which contributes to better system performance.

Maximizing Network Utility and Network Lifetime in Energy-Constrained Ad Hoc Wireless Networks

  • Casaquite, Reizel;Hwang, Won-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1023-1033
    • /
    • 2007
  • This study considers a joint congestion control, routing and power control for energy-constrained wireless networks. A mathematical model is introduced which includes maximization of network utility, maximization of network lifetime, and trade-off between network utility and network lifetime. The framework would maximize the overall throughput of the network where the overall throughput depends on the data flow rates which in turn is dependent on the link capacities. The link capacity on the other hand is a function of transmit power levels and link Signal-to-Interference-plus-Noise-Ratio (SINR) which makes the power allocation problem inherently difficult to solve. Using dual decomposition techniques, subgradient method, and logarithmic transformations, a joint algorithm for rate and power allocation problems was formulated. Numerical examples for each optimization problem were also provided.

Decentralized Frequency Allocation Scheme in Vehicle-mounted Mobile Relay System (차량 탑재형 이동 중계기의 분산 주파수 분할 기법)

  • Shin, Yun-Jae;Lee, Jung-Ryun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7C
    • /
    • pp.592-600
    • /
    • 2012
  • In this paper, we proposed that decentralized frequency allocation scheme(DFAS) without network entry procedure between relays in mobile relay system. Frequency Indicator(FI) signal which is the reference signal of frequency division of each relay and Energy Detection(ED) region are defined. In addition, the mobile connected to the relay transmits the FI signal to neighbor relays in order to facilitate communication between relays. Finally, by using this scheme, the cell throughput improvement is confirmed.

Study on the System of Heating Cost Allocation of Apartments (I) (아파트 난방비 징수제도 개선에 관한 연구 (I))

  • Park S.D;Park H.S;Woo J.S;Yoo H.H;Kong S.H;Yoo S.K
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.140-153
    • /
    • 1987
  • Main objective of this study is to provide heating cost allocation method according to the amount of heating energy consumption in apartments. Heating energy consumptions are calculated by DOE-2.1A program. As a result, heat loss ratio in Ondol heating system, heating cost coefficients of apartments and its using method is presented. Maximum heating cost coefficient rate is 2.63.

  • PDF

Allocation Strategies of Controllable Loads for Load Aggregator in Power Market (부하관리사업자의 부하배분 전략)

  • Lee, C.J.;Cho, K.S.;Kim, H.C.;Park, J.B.;Shin, J.R.;Kim, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.630-632
    • /
    • 2003
  • This paper describes allocation strategies of controllable loads for load aggregator in power market with the direct load control (DLC) program, which is carried out the two-way confirmation procedure. So, it is needed to the priority among the controllable loads to perform effectively and quickly the confirmation task. In this paper, allocation strategies for market operator and/or load aggregator are proposed, which are based on the basic load patterns defined in this paper. To verify the soundness of proposed strategies. case study on a sample system is performed.

  • PDF