• Title/Summary/Keyword: Energy(EMS)

Search Result 191, Processing Time 0.041 seconds

A Economic Feasibility Analysis of Energy Saving Technology Application to Underground Subway Station

  • Kim, Hyungchul;Shin, Seungkwon;Jung, Hosung;Kim, Jin-o;Cha, Junmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • In Korea, new total energy-saving solution has planned to build test-bed in underground subway station. Breaking energy is one of the most energy saving method in railway, but it has not be fully used up for economical purpose. This paper demonstrates on energy saving technology application including breaking energy and heating energy to underground subway station. It also offer solution of optimization of power energy flow. Moreover, economic feasibility analysis performed for undergound test bed constuction.

Development of Sensor Based Energy Management System (센서기반 에너지 모니터링 프로토타입 시스템)

  • Um, Dae-Jin;Choi, Jung-In;Lee, Ingyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.69-74
    • /
    • 2014
  • With the increasing interest of energy efficiency, several buildings and factories begin to monitor energy usages with a built-in energy management system. However, the built-in energy monitoring system does not reflect the dynamics of buildings and factories energy usage. To overcome the latter, we deploy several sensors to monitor the dynamics of buildings energy usage patterns. In this paper, we are proposing a framework of a sensor based energy monitoring system. Based on our limited experiments, we can monitor power usages by a person, device and time period. As a result, we can plan a better energy usage and improve energy efficiency by the monitored energy usage profile data.

Seismic Fragility Function for Existing Low-Rise Piloti-Type Buildings Reflecting Damage From Pohang Earthquake (포항지진의 피해 결과를 반영한 기존 저층 필로티 건물의 지진취약도함수)

  • Kim, Jinyoung;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.251-259
    • /
    • 2021
  • Current seismic fragility functions for buildings were developed by defining damage state threshold based on story drift concerning foreign references and using the capacity spectrum method based on spectral displacement. In this study, insufficient details and dependence on the core location of piloti-type buildings were not reflected in the fragility function because it was developed before the Pohang earthquake. In order to develop an improved one for piloti-type buildings, several types of core were selected, damage state threshold was determined based on the capacity of structural members, and three-dimensional analyses were utilized. As a result, seismic fragility functions based on spectral acceleration were developed for various core locations and different shear strengths of the column stirrup. The fragility of piloti-type buildings significantly varied according to core location, an additional single wall, and whether the contribution of column stirrup was included or not. To estimate fragility more reasonably, it is necessary to prepare the parameters to reflect actual state well.

Seismic Fragility of Low-rise Piloti Buildings Designed According to KDS 41 17 00 (KDS 41 17 00에 따라 설계된 저층 필로티 건물의 지진 취약도)

  • Joo, Changhyeok;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2022
  • The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.

Improvement of Environmental Management in Small and Medium-Sized Firms through the Implementation of Environmental Management System (환경경영시스템의 도입에 따른 중소기업의 환경경영 개선)

  • 이근상;정혜철
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.2
    • /
    • pp.1-14
    • /
    • 2004
  • As environmental issues have been become critical concerns of business, many domestic small and medium enterprises(SME's) are rapidly accepting environmental management systems(EMS) that confirm ISO 14001 guidelines. The purpose of this paper is to present the results of an empirical study carried out on a sample of certified SME's with the aim of identifying obstacles encountered in adopting ISO 14001 standards and the impact of environmental systems on corporate performance after implementation of the ISO 14001 registration process. Data from this study show that the vast majority of respondents reported environmental improvements related to the implementation of an ISO 14001 EMS, especially in the area of employees' participation of the environmental management and responsibilities for reducing negative impacts, energy and resource conservation, materials reuse, and raising top management commitment. The greatest obstacles for implementing the ISO 14001 standard are lack of cooperation and a scarcity of resources such as personnel, money, and time. Results of this study serve as a reference point understanding the problems in the implementation of ISO 14001 in other small and medium firms.

Implementation of the Optimal Power Flow in Korean Energy Management System (한국형 EMS 최적조류계산 적용방안)

  • Seo, Eun-Sung;Lee, Jin-Su;Lee, Hyo-Sang;Min, Sang-Won;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.206-208
    • /
    • 2008
  • 본 논문은 한국형 에너지관리시스템(K-EMS)의 발전계획 응용프로그램 기능중 하나인 최적 조류계산 기능에 관한 것이다 최적조류계산(OPF) 기능의 목적은 전력계통의 상태를 향상시킬 수 있는 전력계통 제어요소를 위한 권고사항을 정하는 것이다. 최적조류계산은 또한 계통 조류 방정식을 만족시키는 동시에 발전기 경제 급전 또는 송전 손실 최소화 등의 급전원의 목적에 맞는 제어 요소의 권고 사항을 정할 수 있다는 강점을 지나고 있다. 이에 본 논문에서는 KEMS에서 적용하려는 최적조류계산의 기능 및 적용방안에 대해서 설명 하고자 한다.

  • PDF

A study on the remote MW control of a steam turbine (원격 급전소에서 발전소 출력을 제어하기 위한 시스템 연구)

  • Kim, Jong-An;Shin, Yoon-Oh
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.734-736
    • /
    • 1999
  • The electricity demand has been in the trend of increase for the past 30 years except last year due to economic crisis. The central electrical power dispatch center anticipates each and every hour's electricity demand and dispatch every power plant's output(MW) taking into account of the costs, frequency regulation abilities, locations, reliabilities and so on. to meet the demand as quickly as possible. The large portion of the power plants' output is contolled automatically by the AGC(Automatic Generation Control) function which is a part of the EMS(Energy Manage System) computer in the dispatch center. To receive the electrical power dispatch signal from the EMS, a power plant should have a remote MW control feature in the turbine control system or unit master control system. We investigated the AGC function and a power plant's remote MW control configuration.

  • PDF

TLF(Transmission Loss Factor) Program Development in K-EMS (한국형 EMS용 송전손실계수(TLF) 산정프로그램 개발)

  • Jung, Sung-Hun;Choi, Young-Jin;Lee, Seung-Ho;Min, Kyung-Il;Moon, Young-Hyun;Kim, Hong-Rae;Lee, Wook-Hwa;Yun, Sang-Yun;Kim, Seon-Gu;Hur, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.81-82
    • /
    • 2008
  • 본 논문은 국책사업으로 진행되는 한국형EMS(K-EMS : Korean Energy Management System)의 응용프로그램 중 하나인 TLF(Transmission Loss Factor)산정 프로그램에 대해 중요 알고리즘과 전반적인 기능에 대해서 기술하였다.

  • PDF

Optimal Operation of Multi-Microgrid Systems Considering Privacy of Customer Information (고객 정보의 개인 정보 보호를 고려한 멀티 마이크로그리드 시스템의 최적 운영)

  • Hussain, Akhtar;Bui, Van-Hai;Kim, Hak-Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.461-463
    • /
    • 2016
  • Information security and preservation of customer's data privacy are key factors for further wide spread adoption of microgrid (MG) technology. However, strong coupling between the operation cost of multi-microgrid (MMG) system and privacy of customer data makes it more challenging. A nested energy management system (EMS) has been proposed in this paper. The surplus/shortage information from the inner level MGs is included in processing the optimal operation of outer level MGs. This type of optimization ensures a layered privacy-preservation to customer at each MG level. The proposed EMS architecture is a better trade-off architecture between the operation cost of the MMG system and customer privacy-preservation at each level of MG.

Development of Energy Management System (에너지관리, 제어 시스템(EMS) 개발)

  • Lee, J.Y.;Choi, Y.S.;Shin, C.G.;Chung, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.854-857
    • /
    • 1998
  • 에너지관리, 제어 시스템(EMS)은 전력계통의 실시간 제어 및 총체적인 관리를 최대화하기 하여 컴퓨터 및 통신 시스템으로 구축된 제어시스템이다. 본 EMS의 주요특성은, 첫째 상당히 빠른 속도로 발전되는 컴퓨터 및 통신 기술들을 수시로 수용할 수 있는 기능, 둘째 상대적으로 지속적이며 오래토록 사용되는 수학적인 알고리즘 및 Buiness Rule들을 처리하는 소프트웨어를 급변하는 Computing 환경에서 적응해 갈 수 있는 기능, 셋째 Heterogenous한 시스템에 접속시킬 수 있는 Database를 갖추었다. 끝으로, 대형 전력계통의 Modeling과 이에 부합하는 실시간 Data로 자동화된 전력계통 실시간 운영상의 결과들을 해석 및 검증하였다.

  • PDF