• 제목/요약/키워드: Endosonography

검색결과 31건 처리시간 0.018초

Endoscopic ultrasound-guided gastrojejunostomy with a direct technique without previous intestinal filling using a tubular fully covered self-expandable metallic stent

  • Hakan Senturk;Ibrahim Hakki Koker;Koray Kochan;Sercan Kiremitci;Gulseren Seven;Ali Tuzun Ince
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.209-216
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasonography-guided gastrojejunostomy is a minimally invasive method for the management of gastric outlet obstruction. Conventionally, a lumen-apposing metal stent (LAMS) is used to create an anastomosis. However, LAMS is expensive and not widely available. In this report, we described a tubular fully covered self-expandable metallic stent (T-FCSEMS) for this purpose. Methods: Twenty-one patients (15 men [71.4%]; median age, 66 years; range, 40-87 years) were included in this study. A total of 19 malignant (12 pancreatic, 6 gastric, and 1 metastatic rectal cancer) and 2 benign cases were observed. The proximal jejunum was punctured with a 19 G needle. The stomach and jejunum walls were dilated with a 6 F cystotome, and a 20×80 mm polytetrafluoroethylene T-FCSEMS (Hilzo) was deployed. Oral feeding was initiated after 12 to 18 hours and solid foods after 48 hours. Results: The median procedure time was 33 minutes (range, 23-55 minutes). After two weeks, 19 patients tolerated oral feeding. In patients with malignancy, the median survival time was 118 days (range, 41-194 days). No serious complications or deaths occurred. All patients with malignancy tolerated oral food intake until they expired. Conclusions: T-FCSEMS is safe and effective. This stent should be considered as an alternative to LAMS for gastric outlet obstruction.

Bispectral index-guided propofol sedation during endoscopic ultrasonography

  • Ayana Okamoto;Ken Kamata;Takeshi Miyata;Tomoe Yoshikawa;Rei Ishikawa;Tomohiro Yamazaki;Atsushi Nakai;Shunsuke Omoto;Kosuke Minaga;Kentaro Yamao;Mamoru Takenaka;Yasutaka Chiba;Toshiharu Sakurai;Naoshi Nishida;Masayuki Kitano;Masatoshi Kudo
    • Clinical Endoscopy
    • /
    • 제55권4호
    • /
    • pp.558-563
    • /
    • 2022
  • Background/Aims: Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). Methods: This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. Results: The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). Conclusions: During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.

Diagnostic Value of Endoscopic Ultrasonography for Common Bile Duct Dilatation without Identifiable Etiology Detected from CrossSectional Imaging

  • Nonthalee Pausawasdi;Penprapai Hongsrisuwan;Lubna Kamani;Kotchakon Maipang;Phunchai Charatcharoenwitthaya
    • Clinical Endoscopy
    • /
    • 제55권1호
    • /
    • pp.122-127
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasonography (EUS) is warranted when cross-sectional imaging demonstrates common bile duct (CBD) dilatation without identifiable causes. This study aimed to assess the diagnostic performance of EUS in CBD dilatation of unknown etiology. Methods: Retrospective review of patients with dilated CBD without definite causes undergoing EUS between 2012 and 2017. Results: A total of 131 patients were recruited. The mean age was 63.2±14.1 years. The most common manifestation was abnormal liver chemistry (85.5%). The mean CBD diameter was 12.2±4.1 mm. The area under the receiver operating characteristic curve (AUROC) of EUS-identified pathologies, including malignancy, choledocholithiasis, and benign biliary stricture (BBS), was 0.98 (95% confidence interval [CI], 0.95-1.00). The AUROC of EUS for detecting malignancy, choledocholithiasis, and BBS was 0.91 (95% CI, 0.85-0.97), 1.00 (95% CI, 1.00-1.00), and 0.93 (95% CI, 0.87-0.99), respectively. Male sex, alanine aminotransferase ≥3× the upper limit of normal (ULN), alkaline phosphatase ≥3× the ULN, and intrahepatic duct dilatation were predictors for pathological obstruction, with odds ratios of 5.46 (95%CI, 1.74-17.1), 5.02 (95% CI, 1.48-17.0), 4.63 (95% CI, 1.1-19.6), and 4.03 (95% CI, 1.37-11.8), respectively. Conclusions: EUS provides excellent diagnostic value in identifying the etiology of CBD dilatation detected by cross-sectional imaging.

Initial United Kingdom experience of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography

  • Puneet Chhabra;Wei On;Bharat Paranandi;Matthew T. Huggett;Naomi Robson;Mark Wright;Ben Maher;Nadeem Tehami
    • 한국간담췌외과학회지
    • /
    • 제26권4호
    • /
    • pp.318-324
    • /
    • 2022
  • Backgrounds/Aims: Gallstone disease is a recognized complication of bariatric surgery. Subsequent management of choledocholithiasis may be challenging due to altered anatomy which may include Roux-en-Y gastric bypass (RYGB). We conducted a retrospective service evaluation study to assess the safety and efficacy of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in patients with RYGB anatomy. Methods: All the patients who underwent EDGE for endoscopic retrograde cholangiopancreatography after RYGB at two tertiary care centers in the United Kingdom between January 2020 and October 2021 were included in the study. Clinical and demographic details were recorded for all patients. The primary outcome measures were technical and clinical success. Adverse events were recorded. Hot Axios lumen apposing metal stents measuring 20 mm in diameter and 10 mm in length were used in all the patients for creation of a gastro-gastric or gastro-jejunal fistula. Results: A total of 14 patients underwent EDGE during the study period. The majority of the patients were female (85.7%) and the mean age of patients was 65.8 ± 9.8 years. Technical success was achieved in all but one patient at the first attempt (92.8%) and clinical success was achieved in 100% of the patients. Complications arose in 3 patients with 1 patient experiencing persistent fistula and weight gain. Conclusions: In patients with RYGB anatomy, EDGE facilitated biliary access has a high rate of clinical success with an acceptable safety profile. Adverse events are uncommon and can be managed endoscopically.

Safety and efficacy of endoscopic ultrasound-guided pancreatic duct drainage using a drill dilator: a retrospective study in Japan

  • Ahmed Sadek;Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara;Toshitaka Fukui;Minako Urata;Takashi Kondo;Yoshitaro Yamamoto;Kenneth Tachi
    • Clinical Endoscopy
    • /
    • 제57권5호
    • /
    • pp.666-674
    • /
    • 2024
  • Background/Aims: Dilation of the tract before stent deployment is a challenging step in endoscopic ultrasound-guided pancreatic duct drainage (EUS-PDD). In this study, we examined the effectiveness and safety of a novel spiral dilator, Tornus ES (Asahi Intec), for EUS-PDD. Methods: This was a retrospective, single-arm, observational study at Aichi Cancer Center Hospital. The punctured tract was dilated using a Tornus ES dilator in all EUS-PDD cases. Our primary endpoint was the technical success rate of initial tract dilation. Technical success was defined as successful fistula dilation using a Tornus ES followed by successful stent insertion. Secondary endpoints were procedure times and early adverse events. Results: A total of 12 patients were included between December 2021 and March 2023. EUS-PDD was performed in 11 patients for post-pancreaticoduodenectomy anastomotic strictures and one patient with pancreatitis with duodenal perforation. The technical success rates of stent insertion and fistula dilation using a Tornus ES dilator was 100%. The median procedure time was 24 minutes. No remarkable adverse events related to the procedure were observed, apart from fever, which occurred in 2 patients. Conclusions: Tract dilation in EUS-PDD using a Tornus ES is effective and safe.

Coaxial plastic stent placement within lumen-apposing metal stents for the management of pancreatic fluid collections: a systemic review and meta-analysis

  • Jad AbiMansour;Veeravich Jaruvongvanich;Saran Velaga;Ryan Law;Andrew C. Storm;Mark Topazian;Michael J. Levy;Ryan Alexander;Eric J. Vargas;Aliana Bofill-Garica;John A. Martin;Bret T. Petersen;Barham K. Abu Dayyeh;Vinay Chandrasekhara
    • Clinical Endoscopy
    • /
    • 제57권5호
    • /
    • pp.595-603
    • /
    • 2024
  • Background/Aims: Coaxial placement of double pigtail plastic stents (DPPS) through lumen-apposing metal stents (LAMSs) is commonly performed to reduce the risk of LAMS obstruction, bleeding, and stent migration when used for the drainage of pancreatic fluid collections (PFCs). A systematic review and meta-analysis were performed to compare the outcomes of LAMS alone and LAMS with coaxial DPPS placement in the management of PFCs. Methods: A systematic review was conducted to identify studies comparing LAMS and LAMS/DPPS for PFC drainage. Primary outcomes included the rate of clinical success, overall adverse events (AEs), bleeding, infection, occlusion, and stent migration. The pooled effect size was summarized using a random-effects model and compared between LAMS and LAMS/DPPS by calculating odds ratios (ORs). Results: Nine studies involving 709 patients were identified (338 on LAMS and 371 on LAMS/DPPS). LAMS/DPPS was associated with a reduced risk of stent obstruction (OR, 0.59; p=0.004) and infection (OR, 0.55; p=0.001). No significant differences were observed in clinical success (OR, 0.96; p=0.440), overall AEs (OR, 0.57; p=0.060), bleeding (OR, 0.61; p=0.120), or stent migration (OR, 1.03; p=0.480). Conclusions: Coaxial DPPS for LAMS drainage of PFCs is associated with a reduced risk of stent occlusion and infection; however, no difference was observed in the overall AE rates or bleeding.

폐주변부 병변의 진단시 기관지 초음파(Endobronchial Ultrasonogram)의 유용성 (The Usefulness of Endobronchial Ultrasonogram for Peripheral Lung Lesion)

  • 김성빈;박진희;김예나;옥철호;장태원;정만홍;천봉권
    • Tuberculosis and Respiratory Diseases
    • /
    • 제67권6호
    • /
    • pp.545-550
    • /
    • 2009
  • Background: Endobronchial ultrasonogram (EBUS) has increased the diagnostic yield of a bronchoscopic biopsy of peripheral pulmonary lesions (PPL). This study evaluated the diagnostic yield of EBUS-guided transbronchial biopsy (TBB) and the visibility of EBUS PPL. Methods: Between August 2007 and November 2008, 50 patients (32 men and 18 women, median age, 61.1${\pm}$10 yrs; range, 16 to 80 yrs) whose PPL lesions could not be detected with flexible bronchoscopy were enrolled in this study. Among the 50 patients, 40 cases were malignant lesions (adenocarcinoma 25, squamous cell carcinoma 10, small cell carcinoma 5) and 10 cases were benign lesions (tuberculoma 7, fungal ball 1, other inflammation 2). Results: The mean diameter of the target lesion was 35.4${\pm}$4.3 mm. Of the 50 patients examined, the overall diagnostic yield by EBUS-TBLB was 46.0% (23/50). The visualization yield of EBUS was 66.0% (33/50). A definitive diagnosis of PPL localized by EBUS was established using EBUS-TBLB in 69.6% (23/33) of cases. The diagnostic yields from washing cytology and brushing cytology from a bronchus identified by EBUS were 27.0% and 45.4% respectively. The diagnostic yields reached 78.7% when the three tests (washing cytology, brushing cytology and EBUS-TBLB) were combined. The visualization yield of EBUS in lesions <20 mm was significantly lower than that in lesions ${\geq}$20 mm (p=0.04). The presence of a bronchus leading to a lesion (open bronchus sign) on the chest CT scan was associated with a high visualization yield on EBUS (p=0.001). There were no significant complications associated with EBUS-TBLB. Conclusion: EBUS-TBLB is a safe and effective method for diagnosing PPL. The lesion size and open bronchus signs are significant factors for predicting the visualization of EBUS.

Is antibiotic prophylaxis necessary after endoscopic ultrasound-guided fine-needle aspiration of pancreatic cysts?

  • Seifeldin Hakim;Mihajlo Gjeorgjievski;Zubair Khan;Michael E. Cannon;Kevin Yu;Prithvi Patil;Roy Tomas DaVee;Sushovan Guha;Ricardo Badillo;Laith Jamil;Nirav Thosani;Srinivas Ramireddy
    • Clinical Endoscopy
    • /
    • 제55권6호
    • /
    • pp.801-809
    • /
    • 2022
  • Background/Aims: Current society guidelines recommend antibiotic prophylaxis for 3 to 5 days after endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of pancreatic cystic lesions (PCLs). The overall quality of the evidence supporting this recommendation is low. In this study, we aimed to assess cyst infection and adverse event rates after EUS-FNA of PCLs among patients treated with or without postprocedural prophylactic antibiotics. Methods: We retrospectively reviewed all patients who underwent EUS-FNA of PCLs between 2015 and 2019 at two large-volume academic medical centers with different practice patterns of postprocedural antibiotic prophylaxis. Data on patient demographics, cyst characteristics, fine-needle aspiration technique, periprocedural and postprocedural antibiotic prophylaxis, and adverse events were retrospectively extracted. Results: A total of 470 EUS-FNA procedures were performed by experienced endosonographers for the evaluation of PCLs in 448 patients, 58.7% of whom were women. The mean age was 66.3±12.8 years. The mean cyst size was 25.7±16.9 mm. Postprocedural antibiotics were administered in 274 cases (POSTAB+ group, 58.3%) but not in 196 cases (POSTAB- group, 41.7%). None of the patients in either group developed systemic or localized infection within the 30-day follow-up period. Procedure-related adverse events included mild abdominal pain (8 patients), intra-abdominal hematoma (1 patient), mild pancreatitis (1 patient), and perforation (1 patient). One additional case of pancreatitis was recorded; however, the patient also underwent endoscopic retrograde cholangiopancreatography. Conclusions: The incidence of infection after EUS-FNA of PCLs is negligible. Routine use of postprocedural antibiotics does not add a significant benefit.

Metastatic tumors to the pancreas: Balancing clinical impression with cytology findings

  • Mohamed A. Abdallah;Kimberlee Bohy;Ashwani Singal;Chencheng Xie;Bhaveshkumar Patel;Morgan E. Nelson;Jonathan Bleeker;Ryan Askeland;Ammar Abdullah;Khalil Aloreidi;Muslim Atiq
    • 한국간담췌외과학회지
    • /
    • 제26권1호
    • /
    • pp.91-97
    • /
    • 2022
  • Backgrounds/Aims: Metastatic lesions of the pancreas (PMET) account for 1%-5% of all malignant solid pancreatic lesions (SPL). In this study we evaluated the utility of endoscopic ultrasonography with fine needle aspiration (EUS-FNA) in diagnosing PMET. Methods: Patients who underwent EUS-FNA at a community referral center between 2011-2017 for SPL were identified. Clinical, radiologic, and EUS-FNA features of those with PMET were compared to those with primary solid tumors of the pancreas: pancreatic adenocarcinoma (PDAC) and neuroendocrine tumors (PNET). Results: A total of 191 patients were diagnosed with solid pancreatic malignancy using EUS-FNA: 156 PDAC, 27 PNET, and eight (4.2%) had PMET. Patients with PMET were less likely to have abdominal pain (25.0% vs. 76.3% vs. 48.2%; p < 0.01) or obstructive jaundice (37.5% vs. 58.3% vs. 0%; p < 0.01) compared to PDAC and PNET. Those with PMET were more likely to have mass lesions with/without biliary or pancreatic ductal dilatations (100% vs. 86.5% vs. 85.2%; p < 0.01) and lower CA19-9 (82.5 ± 43.21 U/mL vs. 4,639.30 ± 11,489.68 U/mL vs. 10.50 ± 10.89 U/mL; p < 0.01) compared to PDAC and PNET. Endosonographic features were similar among all groups. Seven (87.5%) patients with PMET had a personal history of malignancy prior to PMET diagnosis. The primary malignancy was renal cell carcinoma in five PMET. Conclusions: PMET are exceedingly rare, comprising less than 5% of SLP. Patients with PMET are less likely to present with symptoms and mostly identified by surveillance imaging for the primary malignancy.

Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study

  • Takeshi Okamoto;Takashi Sasaki;Tsuyoshi Takeda;Tatsuki Hirai;Takahiro Ishitsuka;Manabu Yamada;Hiroki Nakagawa;Takafumi Mie;Takaaki Furukawa;Akiyoshi Kasuga;Masato Ozaka;Naoki Sasahira
    • Clinical Endoscopy
    • /
    • 제57권4호
    • /
    • pp.515-526
    • /
    • 2024
  • Background/Aims: The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO). Methods: Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared. Results: Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS. Conclusions: No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.