• Title/Summary/Keyword: Endoscopic

Search Result 1,441, Processing Time 0.033 seconds

Calcified Macroplastique Substance: A Rare Cause of Recurrent Gross Hematuria after Endoscopic Injection

  • Seo, Min Hae;Song, Ji Yeon;Chung, Jae Min;Lee, Sang don;Kim, Su Young;Kim, Seong Heon
    • Childhood Kidney Diseases
    • /
    • v.22 no.2
    • /
    • pp.71-74
    • /
    • 2018
  • Endoscopic subureteral injection for treatment of vesicoureteral reflux (VUR) is known to be safe and efficient due to its minimal invasive nature. Being non-migratory, non-antigenic, and biocompatible, Macroplastique (Polydimethylsiloxane) is likely to be stable over time. A 5-year-old boy with a past history of subureteral administration of Macroplastique for unilateral Grade V VUR 4 years ago presented with recurrent gross and microscopic hematuria, along with suprapubic pain. On computed tomography (CT) abdomen, calcified material, suspected to be a stone, was visualized in the bladder. On diagnostic cystoscopy, calcification was seen around the orifice site where Macroplastique injection had been performed. We removed the calcific material by Holmium laser. Endoscopic subureteric implantation has several advantages, but nevertheless, vigilance is needed to detect long-term complications, especially in patients with gross or microscopic hematuria.

Esthetic neck dissection using an endoscope via retroauricular incision: a report of two cases

  • Kim, Jae-Young;Cho, Hoon;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • Various surgical techniques, such as endoscopic surgery and robotic surgery, are developed to optimize the esthetic outcome even in operations for malignancy. A modified face-lift or retroauricular approach are used to minimize postoperative scarring. Recently, robot-assisted surgery is being done in various fields and considered as favorable treatment method by many surgeons. However its high cost is a nonnegligible fraction for many patients. On the other hand, endoscopic surgery, which is cheaper than robotic surgery, is minimally invasive with contentable neck dissection. Although it is a difficult technique for a beginner surgeon due to its limited operation view, we suppose it as an alternative method for robotic surgery. Herein, we report two cases of endoscopic neck dissection via retroauricular incision with a discussion regarding the pros and cons of endoscopic neck dissection.

Endoscopic Mucosal Resection (내시경 점막 절제술)

  • Kim, Gwang Ha
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2011
  • Diagnosis of early esophageal cancer has become more frequent as a result of improved endoscopic technology, surveillance programmes, and increasing experience and awareness on the part of endoscopists. In early esophageal cancer, squamous cell carcinoma and early adenocarcinoma must be managed differently because they have different origins, pathogenesis. and clinical characteristics. The current treatment options vary widely, from extended resection with lymphadenectomy to endoscopic mucosal resection (EMR) or ablation. None of these treatment options can be recommended universally. Instead, an individualized strategy should be based on the depth of tumor infiltration into the mucosa or submucosa, the presence or absence of lymph node metastases, the multicentricity of tumor growth, the length of the segment of intestinal metaplasia, and comorbidities of the patient. EMR has become increasingly important, both as a diagnostic tool for the staging of esophageal carcinomas and as a method of carrying out definitive treatment when the cancer meets certain criteria in which the risk of lymph-node metastasis is negligible. EMR may be sufficient in a subset of patients who have m1 or m2 squamous cell carcinoma and in patients who have isolated foci of high-grade intraepithelial neoplasia or mucosal cancer.

  • PDF

General considerations and updates in pediatric gastrointestinal diagnostic endoscopy

  • Kim, Yong-Joo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.9
    • /
    • pp.817-823
    • /
    • 2010
  • Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review.

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

Clinical Outcomes of Percutaneous Endoscopic Laser Lumbar Discectomy (요추 추간판 탈출증에 대한 경피적 내시경 레이저 수핵 제거술 후 임상 결과)

  • Chang, Won Sok;Lee, Sang Ho
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.34-38
    • /
    • 2005
  • Background: Over the years, disc surgery has progressively evolved in the direction of decreasing trauma and its invasiveness. Conventional open surgery has many complications, such as scarring, instability, bleeding and a relative high mortality rate. Minimally invasive spinal surgery is now an alternative to a traditional discectomy. Herein, we present an operative technique, and the early results, for a percutaneous endoscopic lumbar discectomy in herniated lumbar disc disease. Methods: 43 patients, including 27 men and 16 women, with ages ranging from 18 to 66 years, were enrolled in this study. All the patients showed a protruded or extruded soft disc herniation at the lumbar level on magnetic resonance imaging and computed tomography. A percutaneous endoscopic lumbar discectomy was applied to the patients, and clinical responses evaluated using MacNab's criteria. Results: 40 patients were regarded as showing successful responses (93.1%), and there were no severe complications, such as a hematoma, nerve injury, postoperative dysesthesia or death. One patient underwent fusion surgery for remnant back pain six month later. Conclusions: We conclude that, in properly selected patients, a percutaneous endoscopic lumbar discectomy is a safe, noninvasive and effective treatment modality for herniated lumbar intervertebral disc disease.

Endoscopic Thyroidectomy - An Experience of Gasless Axillary Approach - (내시경 갑상선절제술 - 무기하 액와부 접근법의 시술 경험 -)

  • Kim Tae-Hyun;Oh Sang-Hoon;Kim Sang-Hyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.1
    • /
    • pp.10-14
    • /
    • 2005
  • Objectives: Various techniques of endoscopic thyroidectomy have been developed in thyroid resection since 1998 in the aspect of excellent cosmetic viewpoint. Of them, we evaluated our experiences and advantages of gasless axillary approach technique for resection of dominant thyroid nodules. Material and Methods: Twenty-nine cases of thyroid nodules were operated by the technique of gasless axillary approach during one year from December 2003 to December 2004. Twenty four patients underwent total lobectomy and five patients were partial lobectomy. Results: The operation time of first case took 300 minutes, however it became gradually shortened with case experiences down to 100-120 minutes. Pathologically, nodular hyperplasia was twenty cases, follicular adenoma five cases, papillary carcinoma three patients, and Hashimoto's thyroiditis one patient. There was no case of conversion to open thyroidectomy. Three cases of postoperative hoarseness were recovered spontaneously in 3 months. Hospital stay was four days for most patients. The cosmetic result was excellent without visible scar in anterior neck and chest. Conclusion: Endoscopic thyroidectomy via gasless axillary approach shows excellent result in cosmetic view point with hidden incision scar at axilla, and shorter hospitalization. However a question of longer operation time for dissection of the long plane over pectoral muscle is still remained.

Emergency Neuroendoscopic Management of Third Ventricular Neurocysticercosis Cyst Presented with Bruns Syndrome : Report of Two Cases and Review of Literature

  • Teegala, Ramesh;Rajesh, K. Ghanta;Raviprasad, V. Yerramsetty;Chennappa, Yemba
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.173-177
    • /
    • 2014
  • Neurocysticercosis is the commonest parasitic disease of the human central nervous system. The incidence of intra ventricular form of neurocysticercosis (NCC) is less common accounting 10-20% that of total central nerve system cysticercosis. Intra ventricular NCC is complicated due, to its high incidence of acute hydrocephalus caused by ball valve mechanism. The only reliable tool for diagnosis of NCC is by neuroimaging with CT or MRI. MRI preferred over CT because of its high specificity and sensitivity. In emergency situations like acute hydrocephalus one can proceed with emergency endoscopic surgery. Through the endoscopic view, intra ventricular NCC (IVNCC) has distinguished morphological features like the full moon sign. This feature not only helps in identification of IVNCC, but also guides in further endoscopic treatment strategy. Authors report two cases of 3rd ventricular NCC with acute hydrocephalus managed with emergency endoscopy. Authors have discussed the clinical features, intra operative endoscopic findings and role of endoscopy in emergency surgery for NCC with acute hydrocephalus.

Endoscopic Management of Pancreaticopleural Fistula in a Child with Hereditary Pancreatitis

  • Lee, Dahye;Lee, Eun Joo;Kim, Ju Whi;Moon, Jin Soo;Kim, Yong-Tae;Ko, Jae Sung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.601-607
    • /
    • 2019
  • Pancreaticopleural fistula (PPF) a fistulous connection between the pancreas and pleural space due to prolonged chronic pancreatitis (CP). PPF is a very rare complication which presents in 0.4% of chronic pancreatitis cases, especially among children. We report a case involving a 3-year-old boy who presented with pleural effusion caused by a PPF, a complication of hereditary pancreatitis, which was, for the first time in Korea, successfully managed with endoscopic treatment. Chest radiography and computed tomography showed massive pleural effusion. Percutaneous catheter drainage was performed. High amylase levels were observed in the pleural fluid and serum, suggesting PPF. The patient was managed with bowel rest and octreotide infusion. Endoscopic retrograde cholangiopancreatography revealed CP, and pleural effusion was successfully managed with stent placement. PRSS1 genetic screening revealed R122H mutation.

Beam-scanning Imaging Needle for Endoscopic Optical Coherence Tomography

  • Yang, Woohyeok;Hwang, Junyoung;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.532-537
    • /
    • 2021
  • We present a compact endoscopic probe in a needle form which has a fast beam-scanning capability for optical coherence tomography (OCT). In our study, a beam-scanning OCT imaging needle was fabricated with a 26G syringe needle (0.46 mm in outer diameter) and a thin OCT imaging probe based on the stepwise transitional core (STC) fiber. The imaging probe could freely rotate inside the needle for beam scans. Hence, OCT imaging could be performed without rotation or translation of the needle body. In our design, the structural integrity of the needle's steel tubing was preserved for mechanical robustness. Probing the optical signal was performed through the needle's own window formed at the end. For hand-held operation of our imaging needle, a light and compact scanner module (130 g and 45 × 53 × 60 mm3) was devised. Connected to the imaging needle, it could provide rotational actuation driven by a galvanometer. Because of its finite actuation range, our scanner module did not need a fiber rotary joint which might add undesirable complexity. The beam scan speed was 20 Hz and supported 20 frames per second at the maximum for endoscopic OCT imaging.