• Title/Summary/Keyword: End_to-end Test

Search Result 2,928, Processing Time 0.037 seconds

Restrained Effect of End Plate on Plane Strain Test Evaluated by Digital Image Correlation Method (디지털 이미지 코릴레이션 기법으로 평가한 평면변형률 시험의 단부 구속 효과)

  • Jang, Eui-Ryong;Choo, Yoon-Sik;Lee, Won-Taeg;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.7
    • /
    • pp.25-36
    • /
    • 2008
  • The plane strain test can reproduce the real field condition and failure behavior precisely over other laboratory shear tests. Accordingly, this test has been utilized to investigate the shearing behaviors associated with overall failure behavior and local deformation of soils. However, most plane strain tests have been carried out with restrained end plates due to difficulties in manufacturing the equipment and also performing it. This restraint induces different results with real field because of shear stress on end plates. In this study, plane strain tests with/without bottom plate restraint were performed on Jumunjin-sand. The measurement of overall and local deformation was accomplished by digital image correlation technique as well as external LVDT. By applying digital image correlation method using two consecutive images captured through the transparent wall, local deformation behavior of various parts inside the specimen was estimated. And the formation and development of shear band caused by the restrained effect of end plate and the deformation mechanism of sand under plane strain condition were examined.

AN INVESTIGATION INTO RADIATION LEVELS ASSOCIATED WITH DISMANTLING THE KOREA RESEARCH REACTOR

  • Choi, Geun-Sik;Kim, Hee-Reyoung;Han, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.468-473
    • /
    • 2010
  • We confirmed that the dismantling of two research reactors with thermal power of $2MW_{th}$ and $100kW_{th}$, respectively, reveals no significant difference between the radiation levels of the research reactor site and the surrounding environment far away from it, from the radiation level aspect. Radiation dose and radioactivity were measured at monitoring points around the research reactor site of the Korea Atomic Energy Research Institute (KAERI) in Seoul and comparison points 0.5 km to 3.3 km from the site. To grasp trends in the radiation levels during dismantling from the end of 2002 to the end of 2007, the gamma radiation dose rate, the accumulated dose, and the radioactivity of the strontium, tritium, and gamma isotopes were statistically treated and estimated. The averages of these items between the two groups, the research reactor site and comparison points, were assessed by applying a T-test with a significance level of 0.05. P-values found by using the T-test were from 0.12 to 0.83 where the values were much higher than the significance level. As a result, no difference was observed between the radiation levels at the research reactor site and at the comparison points by this T-test. This study showed that dismantling activity of the Korea Research Reactor of the Seoul site did not expose the public or the environment to harmful levels of radiation.

End Bearing Load Transfer Behavior of Rock Socketed Drilled Shafts (암반에 근입된 현장타설말뚝의 선단하중전이거동 분석)

  • Cho, Hoo-Yeon;Jung, Sang-Sum;Seol, Hoon-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.77-93
    • /
    • 2009
  • The load distribution and deformation of rock socketed drilled shafts subjected to axial loads were evaluated by a load transfer approach. The emphasis was laid on quantifying the end bearing load transfer characteristics of rock socketed drilled shafts based on 3D Finite Difference (FD) analysis performed under varying rock strength and rock mass conditions. From the results of FD analysis, it was found that the ultimate unit toe resistance ($q_{max}$) was influenced by both rock strength and rock mass conditions, while the initial tangent of end bearing load transfer curve ($G_{ini}$) was only dependent on rock strength. End bearing load transfer function of drilled shafts socketed in rock was proposed based on the FD analysis and the field loading tests which were performed on weathered rock in South Korea. Through the comparison with the results of the field loading tests, it is found that the load transfer curve by the present study is in good agreement with the general trend observed by field loading tests, and thus represents a significant improvement in the prediction of load transfer behavior of drilled shaft.

Development of Non-Destrutive Pile Soundness Test Using HWAW Method (HWAW(Harmonic Wavelet Analysis of Wave) 방법을 사용한 말뚝기초의 비파괴 건전도 평가방법의 개발)

  • Park, Hyung-Choon;Kim, Dong-Soo;Cho, Sung-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.13-23
    • /
    • 2008
  • The evaluation of soundness of pile is very important for the safety of super structure. In this paper, the HWAW(Harmonic Wavelet Analysis of Wave) method which is developed to determine phase and group velocities of waves is applied to evaluate integrity of pile non-destructivly. The proposed method can evaluate a soundness of pile and pile end condition which is very important factor for pile behaviour. To verity the applicability of HWAW method in non-destructive test for pile, the numerical simulation test using ABAQUS was performed. And the model pile was made and the proposed non-destructive pile tests were applied to evaluate soundness and end boundary condition of model pile in the air and soil box. Through a numerical simulation and model tests, it is shown that the HWAW method has good potential of applying to the evaluation of pile integrity.

Test Pattern Generation in VHDL Design using Software Testing Method (소프트웨어 검사방법을 이용한 VHDL 설계에서의 테스트 패턴 생성)

  • 박승규;김종현김동욱
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1065-1068
    • /
    • 1998
  • This paper proposes a new test generation method. Most of the test generation methods are gate-level based, but our scheme is VHDL based, especially in other word, behavioral-level based. Our test pattern generation method uses software test method. And we generate deterministic test pattern with this method. The purpose of our method is to reduce the time and effort to generate the test patterns for the end-product test of IC.

  • PDF

Vehicle Recognition of ADAS Vehicle in Collision Situation with Multiple Vehicles in Single Lane (한 차선 내 복수 차량이 존재하는 추돌 상황에서의 ADAS 차량의 차량 인식에 관한 연구)

  • Lee, Seohang;Park, Sanghyeop;Choi, Inseong;Jeong, Jayil
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.2
    • /
    • pp.44-52
    • /
    • 2019
  • In this study a safety evaluation method is presented for a ADAS vehicle to be tested in collision situation when multiple vehicles are present on a single lane. Test scenarios are developed based on Euro-NCAP assessment scenarios, accident database and related simulation results in previous works. An automated evaluation system that is called as the K-target mover is used for active safety evaluation experiments. The experiments are conducted with two types of tests. First, the rear-end collision tests with 25% and 50% overlap for the test vehicle and target vehicle are conducted with the two kinds of test vehicles. On the other hand, the rear-end collision tests which include multiple vehicles in a single lane with 25% and 50% overlaps, are also conducted. Experimental results show that the test vehicles with ADAS cannot recognize the collision situation sometimes in the developed test scenarios, even in the case that the test vehicle showed stable performance in the simple overlap scenarios.

Validation of the Korean Version of the End-Stage Renal Disease Adherence Questionnaire (한국어판 말기신부전 환자의 치료순응도 측정 도구의 타당도와 신뢰도 검증)

  • Kim, Youngmee;Park, Young Mi
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.307-316
    • /
    • 2012
  • Purpose: The purpose of this study was to develop and test psychometric properties the Korean version of the End-Stage Renal Disease Adherence Questionnaire (KESRD-AQ). The ESRD-AQ, a 46-item, multidimensional, self-administrated questionnaire which was developed to assess treatment adherence to hemodialysis (HD) attendance, medications, fluid restrictions, and diet prescription among patients on maintenance hemodialysis, has been validated. Methods: The KESRD-AQ was developed by performing both translation and backtranslation. The content validity and test- retest reliability of the KESRD-AQ were evaluated by establishing item-level content validity index (I-CVI) and intra-class correlation coefficients (ICC), respectively. Construct validity was assessed by adopting a known-group analysis comparing adheres and non-adherers using Mann-Whitney U Test. Results: 41 Korean-American patients with ESRD on HD from 3 outpatient dialysis centers in California participated in the study. The KESRD-AQ showed excellent content validity (average I-CVI=.96) and test-retest reliability (ICC=.917, p=.004). The construct validity indicated that the KESRD-AQ distinguished adheres and non-adheres (p=.02~.047). Conclusion: The KESRD-AQ is a valid and reliable instrument to measure treatment adherence.

A Study on the Estimation of Dynamic Interlaminar Fracture Toughness on CFRP Laminates Plates (CFRP 적층판의 동적 층간파괴인성의 평가법)

  • 김지훈;김영남;판부직규;양인영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.80-91
    • /
    • 1998
  • In this paper, the estimation of dynamic interlaminar fracture toughness on fracture mode II in CFRP(carbon fiber reinforced plastics) laminates in made. Dynamic ENF(End Notched Flexure) apparatus used in this paper is manufactured by suing Split Hopkinson Pressure Bar. The static and impact load history in the CFRP specimen is measured by using manufactured dynamic ENF tester and 3-point bending test is carried out to find the load history. Also dynamic interlaminar fracture toughness can be found by using the J integral obrained from dynamic analysis in consideration of intertia-force effect.

  • PDF

A Study on 30 kVA Super-Conducting Generator Performance using Open Circuit, Short Circuit Characteristics, and Load Tests (개방회로, 단락회로 특성시험 및 부하시험을 이용한 30 kVA 초전도 발전기의 특성해석)

  • Ha, Gyeong-Deok;Hwang, Don-Ha;Park, Do-Yeong;Kim, Yong-Ju;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.2
    • /
    • pp.85-92
    • /
    • 2000
  • 30 kVA rotating-field type Super-Conducting Generator is built and tested with intensive FE(Finite Element) analysis. The generator is driven by VVVF inverter-fed induction motor. Open Circuit Characteristic(OCC) and Short Circuit Characteristic(SCC) are presented in this paper. Also, the test result under the light load(up to 3.6 kW) are given. From the design stage, 2-D FE analysis coupled with the external circuit has been performed. The external circuit includes the end winding resistance and reactance as well as two dampers. When compared with the test data, the FE analysis results show a very good agreement.

  • PDF

Development of the Front End Cooling Fan of the Car (자동차 프런트 엔드 쿨링팬 개발)

  • Oh, Keon-Je;Lee, Su-Hwa;Bae, Chun-Keun;Ju, Phil-Ho;Kim, Jong-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.887-892
    • /
    • 2003
  • A front-end cooling fan is designed and tested in the present study. The design technique is developed using the one-dimensional inviscid flow through the fan blade, the empirical equations, and the experimental correlations. Design data for the blade can be obtained for a given flow rate and a pressure rise. A parabolic function is used to generate a sweep of the fan. Characteristics of the blade geometry are discussed between the huh and the tip. The fan is tested in the fan test unit. The measured volume flow rate at the operating point is in good agreement with that of the design specifications. Sound pressure levels of the noise are predicted with the Ffowcs Williams-Hawkings equations. Calculation results of the sound pressure level(SPL) 1m away from the fan are obtained and cpmpared with the measured data.

  • PDF